Data Quality Reports for Session: 140763 User: sekiya1kei Completed: 02/23/2012


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D030131.1TWP/SMET/C2 - Temperature Sensor Failed, Data Missingtwpsmet60sC2.a1, twpsmet60sC2.b1
D030501.5TWP/SMET/C2 - Upper wind sensor failedtwpsmet60sC2.b1
D030527.8TWP/VCEIL/C2 - Power outage in I-Van resulted in Missing Datatwpvceil25kC2.a1, twpvceil25kC2.b1, twpvceil25kC2.00
D040726.1TWP/SMET/C2 - Negative rainfall ratestwpsmet60sC2.b1
D060818.2TWP/SMET/C2 - Reprocess: Barometric pressure units change twpsmet60sC2.b1
D061011.3TWP/SMET/C2 - Reprocess: Tipping bucket rain gauge addedtwpsmet60sC2.b1
D081022.5TWP/SMET/C2 - Wind Speed data contain offset due to induced voltagetwpsmet60sC2.b1
D100215.5TWP/VCEIL/C2 - Reprocess: Incorrect serial_number and sum_backscatter fieldstwpvceil25kC2.b1


DQRID : D030131.1
Start DateStart TimeEnd DateEnd Time
01/24/2003010001/30/20030500
Subject:
TWP/SMET/C2 - Temperature Sensor Failed, Data Missing
DataStreams:twpsmet60sC2.a1, twpsmet60sC2.b1
Description:
The T/RH sensor on Nauru failed and was replaced (only the temperature sensor failed).
Measurements:twpsmet60sC2.b1:
  • Temperature maximum(temp_max)
  • temp_sd
  • Temperature minimum(temp_min)
  • Mean Air Temperature or Hardware Error(temp_mean)

twpsmet60sC2.a1:
  • Mean Air Temperature or Hardware Error(temp_mean)
  • temp_sd
  • Temperature maximum(temp_max)
  • Temperature minimum(temp_min)


Back To Table of Contents

DQRID : D030501.5
Start DateStart TimeEnd DateEnd Time
04/12/2003100004/24/20030020
Subject:
TWP/SMET/C2 - Upper wind sensor failed
DataStreams:twpsmet60sC2.b1
Description:
The upper wind speed sensor failed.  Wind speeds were reported as 0 m/s and wind direction 
data was not in agreement with the lower wind sensor. Anemometer was replaced.
Measurements:twpsmet60sC2.b1:
  • up_dir_vec_avg
  • up_spd_min
  • up_spd_arith_avg
  • up_dir_sd
  • up_spd_sd
  • up_spd_max
  • up_spd_vec_avg


Back To Table of Contents

DQRID : D030527.8
Start DateStart TimeEnd DateEnd Time
05/24/2003230005/25/20030010
Subject:
TWP/VCEIL/C2 - Power outage in I-Van resulted in Missing Data
DataStreams:twpvceil25kC2.a1, twpvceil25kC2.b1, twpvceil25kC2.00
Description:
I forgot to put in the daily report that we took the I van down yesterday to replace the 
fans in the Clary UPS. This was from 2300z on 24May03 to 0010z on 25May03. Instruments 
affected :

MPL
Ceilometer
MWR
WSI
TSI

Rex
Measurements:twpvceil25kC2.b1:
  • lon
  • Third cloud base height(third_cbh)
  • Second lowest cloud base height(second_cbh)
  • alt
  • background_light
  • Backscatter(backscatter)
  • receiver_sensitivity
  • base_time
  • status_string
  • detection_status
  • laser_pulse_energy
  • alt_highest_signal
  • filename
  • laser_temperature
  • range
  • measurement_parameters
  • status_flag
  • Lowest cloud base height detected.(first_cbh)
  • lat

twpvceil25kC2.00:
  • Raw data stream - documentation not supported

twpvceil25kC2.a1:
  • lat
  • lon
  • receiver_sensitivity
  • range
  • sum_backscatter
  • Third cloud base height(third_cbh)
  • base_time
  • Backscatter(backscatter)
  • measurement_parameters
  • tilt_angle
  • laser_temperature
  • laser_pulse_energy
  • alt_highest_signal
  • alt
  • Lowest cloud base height detected.(first_cbh)
  • status_string
  • Vertical visibility(vertical_visibility)
  • detection_status
  • background_light
  • Second lowest cloud base height(second_cbh)
  • status_flag
  • window_contamination
  • time_offset
  • filename


Back To Table of Contents

DQRID : D040726.1
Start DateStart TimeEnd DateEnd Time
10/21/1998031107/06/20040138
Subject:
TWP/SMET/C2 - Negative rainfall rates
DataStreams:twpsmet60sC2.b1
Description:
Due to limitations of the Zeno dataloggers all voltage measurements
from the optical rain gauge (ORG) were converted to rainfall rates. 
This resulted in negative values for rain rates.  Any value below
0.10 mm/hr should be considered to be 0 mm/hr.  New dataloggers 
alleviated this problem.
Measurements:twpsmet60sC2.b1:
  • Precipitation minimum(precip_min)
  • Precipitation mean(precip_mean)
  • Precipitation maximum(precip_max)
  • precip_sd


Back To Table of Contents

DQRID : D060818.2
Start DateStart TimeEnd DateEnd Time
10/21/1998000007/06/20042359
Subject:
TWP/SMET/C2 - Reprocess: Barometric pressure units change
DataStreams:twpsmet60sC2.b1
Description:
Barometric pressure data during this time period is reported in hPa.  After this time, the 
data have been converted to kPa to standardize the measurement units among ARM sites and 
to conform to accepted standard units determined by the scientific community.
Measurements:twpsmet60sC2.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D061011.3
Start DateStart TimeEnd DateEnd Time
10/21/1998000011/29/20062014
Subject:
TWP/SMET/C2 - Reprocess: Tipping bucket rain gauge added
DataStreams:twpsmet60sC2.b1
Description:
A tipping bucket rain gauge was added to the TWP.C2 SMET suite of instruments on 20061129. 
Effective 20060926, two new variables (count and rain amount) were added to the end of 
the twpsmet60sC2.b1 datastream.  Between 9/26 and 11/29, the data for these two variables 
are filled with zeros.  Users should not use the data during this period as the zeros are 
not representative of the rain fall at the site.  When reprocessing of this datastream 
occurs these variables will be added for the 19981021-20060926 and data from 
19981021-20061129 will be filled with -9999 (missing).
Measurements:twpsmet60sC2.b1:
  • base_time


Back To Table of Contents

DQRID : D081022.5
Start DateStart TimeEnd DateEnd Time
11/01/1998000002/23/20090410
Subject:
TWP/SMET/C2 - Wind Speed data contain offset due to induced voltage
DataStreams:twpsmet60sC2.b1
Description:
The marine model of the RM Young wind sensor needs twisted pair shielded cable.  The 
manufacturer did not originally supply the pigtail with twisted pair shielded cable.  Use of 
twisted pair shielded cable for the rest of the cable run to the logger was also not 
specified.  This caused an induced voltage in the wind speed line from the wind direction 
excitation.  The induced voltage varied from sensor to sensor and probably changed anytime 
the cable was replaced or parts of the wind sensor were repaired or replaced. The induced 
voltage has been seen to vary from 0.15 m/s to as much as 1.08 m/s.
Measurements:twpsmet60sC2.b1:
  • lo_spd_arith_avg
  • lo_spd_min
  • lo_spd_vec_avg
  • up_spd_min
  • up_spd_arith_avg
  • lo_spd_max
  • up_spd_sd
  • up_spd_max
  • lo_spd_sd
  • up_spd_vec_avg


Back To Table of Contents

DQRID : D100215.5
Start DateStart TimeEnd DateEnd Time
10/28/1998000010/31/20092359
Subject:
TWP/VCEIL/C2 - Reprocess: Incorrect serial_number and sum_backscatter fields
DataStreams:twpvceil25kC2.b1
Description:
Attribute serial_number: In most cases, this field is not representative of the actual 
serial number of the instrument because the value did not change when an instrument changed 
locations or was replaced with a spare.
   
Variable sum_backscatter: An out-of-range condition for the "sum of detected and 
normalized backscatter" was reported as 0 instead of missing (-9999). The valid range is 0 - 
0.0999 /srad.
   
This DQR also applies to a1 level data.
Measurements:twpvceil25kC2.b1:
  • sum_backscatter


Back To Table of Contents