D081022.13HFE/MET/M1 - Wind speed data contain offset due to induced voltagehfemetM1.b1
D090211.6HFE/AOS/M1 - CCN missinghfeaosccnM1.a1
D090216.3HFE/MET/M1 - Intermittent barometer failurehfemetM1.b1
D090216.4HFE/MET/M1 - Intermittent PWD datahfemetM1.b1
D090220.2HFE/MET/M1 - ORG measuring ice crystals or foghfemetM1.b1
D090220.3HFE/MET/M1 - Induced voltage on wind speed sensor cablehfemetM1.b1
D090512.1HFE/MET/S1 - Barometer missinghfemetS1.b1
D090512.2HFE/MET/S1 - Optical Rain Gage FailedhfemetS1.b1
D090512.3HFE/MET/S1 - Wind Data IncorrecthfemetS1.b1
D101020.3HFE/AOS/M1 - Data processing problemhfeaosM1.a1, hfenoaaaosM1.b1, hfenoaaaosavgM1.b1
D111122.2HFE/AOS/M1 - CPC and CCN data questionablehfeaosccnM1.a1, hfenoaaaosM1.b1


DQRID : D081022.13
Start DateStart TimeEnd DateEnd Time
05/19/2008000012/28/20082159
Subject:
HFE/MET/M1 -  Wind speed data contain offset due to induced voltage
DataStreams:hfemetM1.b1
Description:
The marine model of the RM Young wind sensor needs twisted pair shielded cable.  The 
manufacturer did not originally supply the pigtail with twisted pair shielded cable.  Use of 
twisted pair shielded cable for the rest of the cable run to the logger was also not 
specified.  This caused an induced voltage in the wind speed line from the wind direction 
excitation.  The induced voltage varied from sensor to sensor and probably changed anytime 
the cable was replaced or parts of the wind sensor were repaired or replaced. The induced 
voltage has been seen to vary from 0.15 m/s to as much as 1.08 m/s.
Measurements:hfemetM1.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D090211.6
Start DateStart TimeEnd DateEnd Time
07/08/2008032007/25/20080429
Subject:
HFE/AOS/M1 - CCN missing
DataStreams:hfeaosccnM1.a1
Description:
A power regulator on the CCN circuit board failed. The mentor replaced it and it was up 
and working on 7/25/2008.
Measurements:hfeaosccnM1.a1:
  • CCN_laser_current
  • AOS bin number of lowest channel of OPC include in summation of N_CCN(N_CCN_bin_number)
  • CCN_FirstStageMonitorVoltage
  • CCN_T_sample
  • CCN_ss_calc
  • CCN_T_TEC1
  • CCN_T_TEC3
  • CCN_T_TEC2
  • CCN_Q_sheath
  • CCN_T_nafion
  • AOS number concentration of CCN(N_CCN)
  • CCN_P_sample
  • CCN_dT_TEC3_TEC1_StdDev
  • CCN_T_inlet
  • Size of upper limit of each CCN bin(CCN_UpperSizeLimit)
  • CCN_ProportionalValveVoltage
  • CCN_temp_unstable_flag
  • CCN_Q_sample
  • CCN_Temperature_Gradient
  • AOS CCN number concentration by bin(N_CCN_dN)
  • CCN_T_OPC
  • CCN_ss_set


Back To Table of Contents

DQRID : D090216.3
Start DateStart TimeEnd DateEnd Time
05/19/2008000012/28/20082159
Subject:
HFE/MET/M1 - Intermittent barometer failure
DataStreams:hfemetM1.b1
Description:
Intermittent barometer failure occurred throughout the deployment.  We were unable to 
pinpoint the cause of the failure.  Typically one or two minutes of missing data occurred 
every few days.

Since pressure data is typically invariant over 1 minute, linear interpolation should be 
fine to fill in missing data.
Measurements:hfemetM1.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D090216.4
Start DateStart TimeEnd DateEnd Time
05/19/2008000012/28/20082159
Subject:
HFE/MET/M1 - Intermittent PWD data
DataStreams:hfemetM1.b1
Description:
The Present Weather Detector had intermittent missing values throughout this deployment.  
Missing values occurred almost everyday, usually just one or two minutes per day.
Measurements:hfemetM1.b1:
  • pwd_pw_code_15min
  • pwd_cumul_rain
  • PWD 1 minute mean visibility(pwd_mean_vis_1min)
  • pwd_precip_rate_mean_1min
  • pwd_err_code
  • PWD 10 minute mean visibility(pwd_mean_vis_10min)
  • pwd_pw_code_inst
  • pwd_pw_code_1hr


Back To Table of Contents

DQRID : D090220.2
Start DateStart TimeEnd DateEnd Time
11/09/2008192011/09/20081956
11/09/2008210811/09/20082304
11/27/2008161411/27/20082331
12/04/2008195512/04/20082351
12/05/2008094612/06/20080013
12/06/2008142412/06/20082322
12/14/2008150012/14/20081532
12/14/2008171212/14/20081726
12/14/2008184812/15/20080052
12/21/2008065712/22/20080232
12/22/2008040812/23/20080043
12/23/2008175412/24/20080006
Subject:
HFE/MET/M1 - ORG measuring ice crystals or fog
DataStreams:hfemetM1.b1
Description:
The ORG was measuring consistent values for long periods of time.  Typically this is 
indicative of fog, ice crystals in the air or poor performance of the lens heaters.
Measurements:hfemetM1.b1:
  • ORG precipitation rate mean(org_precip_rate_mean)


Back To Table of Contents

DQRID : D090220.3
Start DateStart TimeEnd DateEnd Time
05/19/2008000012/28/20082359
Subject:
HFE/MET/M1 - Induced voltage on wind speed sensor cable
DataStreams:hfemetM1.b1
Description:
The cable for the wind monitor is not a twisted pair shielded cable.  This caused an 
induced voltage on the wind sensor wires from the wind direction measurement excitation 
voltage.  A small offset is added into the wind speeds.  This value varies.  Most frequently 
the values of 0.49, 0.588 and 0.686 m/s were added into the wind speed.  On 11/27/2008 the 
value jumped to 0.98 m/s for most of the day.
Measurements:hfemetM1.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D090512.1
Start DateStart TimeEnd DateEnd Time
05/20/2008000007/28/20080905
Subject:
HFE/MET/S1 - Barometer missing
DataStreams:hfemetS1.b1
Description:
All spare barometers and the working barometer for this supplemental site were damaged 
during shipment.  They were sent in for repair and recalibration.
Measurements:hfemetS1.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D090512.2
Start DateStart TimeEnd DateEnd Time
05/20/2008000010/22/20082359
Subject:
HFE/MET/S1 - Optical Rain Gage Failed
DataStreams:hfemetS1.b1
Description:
All data collected by the ORG is of no use.  The ORG had failed and any data collected was 
not indicative of the current weather.
Measurements:hfemetS1.b1:
  • precip_rate_max
  • precip_rate_sd
  • Rain, surface, 1-min avg(precip_rate_mean)
  • org_carrier_mean
  • precip_rate_min


Back To Table of Contents

DQRID : D090512.3
Start DateStart TimeEnd DateEnd Time
08/18/2008115808/19/20080518
Subject:
HFE/MET/S1 - Wind Data Incorrect
DataStreams:hfemetS1.b1
Description:
The wind sensor became disconnected and no wind speed or direction data were collected.
Measurements:hfemetS1.b1:
  • wind_dir_sd
  • wind_spd_arith_min
  • Wind speed, lower, 1-min avg(wind_spd_arith_avg)
  • wind_spd_arith_max
  • Vector-averaged Wind Speed(wind_spd_vec_avg)
  • wind_spd_arith_sd
  • Vector-averaged Wind Direction(wind_dir_vec_avg)


Back To Table of Contents

DQRID : D101020.3
Start DateStart TimeEnd DateEnd Time
05/09/2008000012/28/20080000
Subject:
HFE/AOS/M1 - Data processing problem
DataStreams:hfeaosM1.a1, hfenoaaaosM1.b1, hfenoaaaosavgM1.b1
Description:
The AOS data was reprocessed for the AMF, SGP and NSA sites. There was an error in the 
processing of the corrections for the PSAP absorption signal such that a low pass filter was 
implemented for the scattering data used in these corrections.The difference between the 
corrected and previous data is < 0.05 Mm-1 (below the instrument detection limit) and 
should not have a significant effect on the previous data. Data will be reprocessed at a 
later time when more significant changes to the data processing are implemented.
Measurements:hfenoaaaosM1.b1:
  • Absorption Coefficient Blue, corrected for flow and sample area, 3 wavelength
    PSAP, 1 um size cut(Ba_B_Dry_1um_PSAP3W_1)
  • Absorption Coefficient Red, corrected for flow and sample area, 3 wavelength
    PSAP, 10 um size cut(Ba_R_Dry_1um_PSAP3W_1)
  • Absorption Coefficient Red, corrected for flow and sample area, 3 wavelength
    PSAP, 10 um size cut(Ba_R_Dry_10um_PSAP3W_1)
  • Aerosol light absorption coefficient, green channel, 10 um particle diameter(Ba_G_Dry_10um_PSAP1W_1)
  • Absorption Coefficient Green, corrected for flow and sample area, 3 wavelength
    PSAP, 1 um size cut(Ba_G_Dry_1um_PSAP3W_1)
  • Absorption Coefficient Green, corrected for flow and sample area, 3 wavelength
    PSAP, 10 um size cut(Ba_G_Dry_10um_PSAP3W_1)
  • Aerosol light absorption coefficient, green channel, 1 um particle diameter(Ba_G_Dry_1um_PSAP1W_1)
  • Absorption Coefficient Blue, corrected for flow and sample area, 3 wavelength
    PSAP, 10 um size cut(Ba_B_Dry_10um_PSAP3W_1)

hfeaosM1.a1:
  • Absorption Coefficient Red, corrected for flow and sample area, 3 wavelength
    PSAP, 10 um size cut(Ba_R_Dry_1um_PSAP3W_1)
  • Aerosol light absorption coefficient, green channel, 10 um particle diameter(Ba_G_Dry_10um_PSAP1W_1)
  • Absorption Coefficient Green, corrected for flow and sample area, 3 wavelength
    PSAP, 10 um size cut(Ba_G_Dry_10um_PSAP3W_1)
  • Absorption Coefficient Green, corrected for flow and sample area, 3 wavelength
    PSAP, 1 um size cut(Ba_G_Dry_1um_PSAP3W_1)
  • Absorption Coefficient Blue, corrected for flow and sample area, 3 wavelength
    PSAP, 10 um size cut(Ba_B_Dry_10um_PSAP3W_1)
  • Absorption Coefficient Red, corrected for flow and sample area, 3 wavelength
    PSAP, 10 um size cut(Ba_R_Dry_10um_PSAP3W_1)
  • Absorption Coefficient Blue, corrected for flow and sample area, 3 wavelength
    PSAP, 1 um size cut(Ba_B_Dry_1um_PSAP3W_1)
  • Aerosol light absorption coefficient, green channel, 1 um particle diameter(Ba_G_Dry_1um_PSAP1W_1)

hfenoaaaosavgM1.b1:
  • Aerosol light absorption coefficient, green channel, 1 um particle diameter(Ba_G_Dry_1um_PSAP1W_1)
  • Aerosol light absorption coefficient, green channel, 10 um particle diameter(Ba_G_Dry_10um_PSAP1W_1)


Back To Table of Contents

DQRID : D111122.2
Start DateStart TimeEnd DateEnd Time
07/25/2008000012/28/20082300
Subject:
HFE/AOS/M1 - CPC and CCN data questionable
DataStreams:hfeaosccnM1.a1, hfenoaaaosM1.b1
Description:
The CPC slowly clogged and the signal declined until the instrument was cleaned at which 
point the signal would increase. The data is still a good relative measure of the daily 
changes in the CN concentration, but the absolute value may be too low.

The mentor was unable to monitor the flow rate and operation in the CCN during operation. 
The relative changes in CCN with %ss are likely fine, but the absolute values may be too 
low or too high. Dust was prevalent at the site and likely contributed to the CCN signal 
such that large dust particles appeared as droplets.
Measurements:hfenoaaaosM1.b1:
  • AOS number concentration of CCN(N_CCN)
  • Condensation Nuclei Concentration Number(N_CPC_1)

hfeaosccnM1.a1:
  • CCN_Q_sheath
  • CCN_Q_sample
  • AOS number concentration of CCN(N_CCN)
  • AOS CCN number concentration by bin(N_CCN_dN)


Back To Table of Contents