Data Quality Reports for Session: 139246 User: venturv Completed: 12/12/2011


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D100510.1SGP/EBBR/E15 - Sensible and Latent Heat Fluxes Low (Net Radiation too low)sgp5ebbrE15.b1, sgp15ebbrE15.b1, sgp30ebbrE15.b1


DQRID : D100510.1
Start DateStart TimeEnd DateEnd Time
03/19/2010193005/05/20101745
Subject:
SGP/EBBR/E15 - Sensible and Latent Heat Fluxes Low
(Net Radiation too low)
DataStreams:sgp5ebbrE15.b1, sgp15ebbrE15.b1, sgp30ebbrE15.b1
Description:
Sensible and Latent Heat Fluxes were measured as being low because of damage to the net 
radiometer.

The Sensible and Latent Heat fluxes can be approximated by taking the ratio of the daytime 
SIRS net radiation to EBBR net radiation, and then multiplying the Sensible and Latent 
Heat Fluxes by that ratio.
Measurements:sgp5ebbrE15.b1:
  • Radiation, net(net_radiation)

sgp30ebbrE15.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Radiation, net(net_radiation)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE15.b1:
  • net_radiation_mv


Back To Table of Contents



END OF DATA