Data Quality Reports for Session: 136759 User: tianyi1luo Completed: 08/15/2011


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D060921.3SGP/EBBR/E12 - Net Radiation, and Sensible and Latent Heat Fluxes Incorrectsgp5ebbrE12.b1, sgp15ebbrE12.b1, sgp30ebbrE12.b1


DQRID : D060921.3
Start DateStart TimeEnd DateEnd Time
08/21/2006120008/29/20061630
Subject:
SGP/EBBR/E12 - Net Radiation, and Sensible and Latent Heat Fluxes Incorrect
DataStreams:sgp5ebbrE12.b1, sgp15ebbrE12.b1, sgp30ebbrE12.b1
Description:
Rain entered into the net radiometer through a broken top dome.  Most of the net radiation 
values during the period are much too large, thus sensible and latent fluxes are also 
too large.
Measurements:sgp30ebbrE12.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Radiation, net(net_radiation)

sgp15ebbrE12.b1:
  • net_radiation_mv

sgp5ebbrE12.b1:
  • Radiation, net(net_radiation)


Back To Table of Contents