Data Quality Reports for Session: 134793 User: jcomstock Completed: 05/10/2011


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D080428.2TWP/SMET/C1 - Reprocess: ORG Data has very small rainrate valuestwpsmet60sC1.b1
D090304.1TWP/SMET/C1 - Optical Rain Gage Inoperativetwpsmet60sC1.b1
D090708.1TWP/SMET/C1 - Reprocess: Barometric pressure data scaled incorrectlytwpsmet60sC1.b1


DQRID : D080428.2
Start DateStart TimeEnd DateEnd Time
08/01/2004000006/30/20102359
Subject:
TWP/SMET/C1 - Reprocess: ORG Data has very small rainrate values
DataStreams:twpsmet60sC1.b1
Description:
The ORG data is collected via analog signal and not digital.  Therefore, we continuously 
collect data even when no rain is occurring.  We also capture small events such as leaves, 
large bugs, dust, etc blowing through the measurement path.  Because this discrete event 
occurs quickly the value is usually captured for 1 or 2 seconds.  This value is then 
averaged to the minute producing rainrate on the order of .009 mm/hr or less.  These values 
are not indicative of rain and should be removed from the record or summing over long 
periods can bias the climate record.  We are reprocessing the data to remove these small 
values and are adjusting the collection program to remove them before ingest.
Measurements:twpsmet60sC1.b1:
  • Precipitation minimum(precip_min)
  • Precipitation maximum(precip_max)
  • precip_sd
  • Precipitation mean(precip_mean)


Back To Table of Contents

DQRID : D090304.1
Start DateStart TimeEnd DateEnd Time
02/07/2009010004/03/20090225
Subject:
TWP/SMET/C1 - Optical Rain Gage Inoperative
DataStreams:twpsmet60sC1.b1
Description:
Beginning on 02/07/2009, the trending between the TBRG and ORG began to look poor, one 
recording precip when the other was not and vice versa.  After a while the ORG quit 
registering any precip at all.  ORG was replaced.
Measurements:twpsmet60sC1.b1:
  • Precipitation minimum(precip_min)
  • Precipitation maximum(precip_max)
  • precip_sd
  • Precipitation mean(precip_mean)


Back To Table of Contents

DQRID : D090708.1
Start DateStart TimeEnd DateEnd Time
07/06/2009231907/07/20091348
Subject:
TWP/SMET/C1 - Reprocess: Barometric pressure data scaled incorrectly
DataStreams:twpsmet60sC1.b1
Description:
The barometer data was scaled incorrectly when a new program was loaded into the 
datalogger.  The pressure data was reported as mb (hPa) instead of the standard kPa.  So, in 
essence the value was a factor of ten to large.
Measurements:twpsmet60sC1.b1:
  • Atmospheric pressure(atmos_pressure)


Back To Table of Contents



END OF DATA