Data Quality Reports for Session: 134221 User: proy Completed: 04/05/2011


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D070521.1SGP/SMOS/E7 - Wind sensor binding at low wind speedssgp1smosE7.b1, sgp30smosE7.b1, sgp1440smosE7.b1
D070618.1SGP/SMOS/E1 - Failed temperature probesgp1smosE1.b1, sgp30smosE1.b1, sgp1440smosE1.b1
D070618.2SGP/SMOS/E13 - RH sensor failuresgp1smosE13.b1, sgp30smosE13.b1, sgp1440smosE13.b1


DQRID : D070521.1
Start DateStart TimeEnd DateEnd Time
05/21/2007000010/30/20071715
Subject:
SGP/SMOS/E7 - Wind sensor binding at low wind speeds
DataStreams:sgp1smosE7.b1, sgp30smosE7.b1, sgp1440smosE7.b1
Description:
The wind sensor bearings were failing causing the wind speed sensor to report lower than 
actual wind speeds when the winds were below 2 m/s.  The wind monitor was replaced on 
05/29/2007 but this failed to correct the problem.  Subsequently, the site was flooded and it 
took some time to re-establish normal operations.  The wind sensor was again replaced on 
10/30/2007.  After replacement the wind data from the SMOS compared more favorably to 
the co-located EBBR data.
Measurements:sgp30smosE7.b1:
  • Wind speed, 30-min intervals, standard deviation(sd_wspd)
  • Wind speed, vector-averaged, at 10-m height, 30-min intervals(wspd_va)
  • Mean Wind Speed(wspd)

sgp1smosE7.b1:
  • Mean Wind Speed(wspd)
  • Wind speed, vector-averaged, at 10-m height, 30-min intervals(wspd_va)

sgp1440smosE7.b1:
  • Time of Minimum Wind Speed(time_min_wspd)
  • Minimum Wind Speed(min_wspd)


Back To Table of Contents

DQRID : D070618.1
Start DateStart TimeEnd DateEnd Time
04/03/2007000006/26/20072025
Subject:
SGP/SMOS/E1 - Failed temperature probe
DataStreams:sgp1smosE1.b1, sgp30smosE1.b1, sgp1440smosE1.b1
Description:
The temperature probe was out of tolerance as it failed the 6-month calibration checks and 
subsequent bi-weekly checks.  The temperature values consistently were outside the 
manufacturers suggested uncertainty of 0.2 C.
Measurements:sgp30smosE1.b1:
  • Temperature, air(temp)
  • sd_vap_pres
  • Pressure, vapor, 60-m height, 30-min intervals(vap_pres)

sgp1440smosE1.b1:
  • Time of Minimum Vapor Pressure(time_min_vap_pres)
  • Time of Maximum Vapor Pressure(time_max_vap_pres)
  • Time of Minimum Temperature(time_min_temp)
  • Time of Maximum Temperature(time_max_temp)
  • Pressure, vapor, at 60-m height, 24-hr minimum(min_vap_pres)
  • Temperature, air, at 60-m height, 24-hr maximum(max_temp)
  • Pressure, vapor, at 60-m height, 24-hr maximum(max_vap_pres)
  • Temperature, air, at 60-m height, 24-hr minimum(min_temp)

sgp1smosE1.b1:
  • Temperature, air(temp)
  • Pressure, vapor, 60-m height, 30-min intervals(vap_pres)


Back To Table of Contents

DQRID : D070618.2
Start DateStart TimeEnd DateEnd Time
04/16/2007000006/18/20072000
Subject:
SGP/SMOS/E13 - RH sensor failure
DataStreams:sgp1smosE13.b1, sgp30smosE13.b1, sgp1440smosE13.b1
Description:
The T/RH sensor relative humidity data is suspect during this time.  Values from this 
sensor failed the 6-month check and subsequent bi-weekly checks.  The RH values were lower by 
larger than the manufacturer suggested uncertainty of 3%.
Measurements:sgp1440smosE13.b1:
  • Time of Minimum Vapor Pressure(time_min_vap_pres)
  • Pressure, vapor, at 60-m height, 24-hr minimum(min_vap_pres)
  • Humidity, relative, at 60-m height, 24-hr maximum(max_rh)
  • Time of Relative Humidity(time_min_rh)
  • Time of Maximum Vapor Pressure(time_max_vap_pres)
  • Humidity, relative, at 60-m height, 24-hr minimum(min_rh)
  • Time of Maximum Relative Humidity(time_max_rh)
  • Pressure, vapor, at 60-m height, 24-hr maximum(max_vap_pres)

sgp1smosE13.b1:
  • Humidity, relative(rh)
  • Pressure, vapor, 60-m height, 30-min intervals(vap_pres)

sgp30smosE13.b1:
  • Humidity, relative(rh)
  • sd_vap_pres
  • Pressure, vapor, 60-m height, 30-min intervals(vap_pres)
  • Humidity, relative, 30-min intervals, standard deviation(sd_rh)


Back To Table of Contents



END OF DATA