Data Quality Reports for Session: 133704 User: vghate Completed: 03/08/2011


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D090508.1GRW/ECOR/M1 - Reprocessed: ECOR Wind direction offset correctedgrw30ecorM1.b1
D110118.2GRW/ECOR/M1 - Effects on ECOR CO2 Flux and Concentration by Aircraftgrw30ecorM1.b1


DQRID : D090508.1
Start DateStart TimeEnd DateEnd Time
04/15/2009153005/08/20091830
Subject:
GRW/ECOR/M1 - Reprocessed: ECOR Wind direction offset corrected
DataStreams:grw30ecorM1.b1
Description:
The ECOR sonic anemometer was initially aligned to an east declination
instead of a west declination.  For the period stated, ECOR wind direction
was 21 degrees too high.

Data were reprocessed 20090602 and archived 20090619.
Measurements:grw30ecorM1.b1:
  • wind_dir


Back To Table of Contents

DQRID : D110118.2
Start DateStart TimeEnd DateEnd Time
04/15/2009153010/11/20100800
Subject:
GRW/ECOR/M1 - Effects on ECOR CO2 Flux and Concentration by Aircraft
DataStreams:grw30ecorM1.b1
Description:
Aircraft landings, departures, and running aircraft on the airport pad were found to 
produce spikes in the half hourly CO2 flux and small spikes in CO2 concentration on many days 
during the entire deployment of the AMF1 at GRW. This influence sometimes occurred 
multiple periods in a day; this was typical of the year of data.  The spikes range from only 
several micromoles s-1 m-2 to one hundred or more for flux (a typical spike was in the 
twenties) and near zero to 1.0 mmoles m-3 for CO2 concentration (typically around 0.15).

Occasionally an influence on water vapor density was detected, but this was fairly rare 
and usually of very small magnitude.
Measurements:grw30ecorM1.b1:
  • variance of variable c(var_c)
  • rotated covariance wc(cvar_rot_wc)
  • covariance uc(cvar_uc)
  • CO2 flux(fc)
  • rotated covariance vc(cvar_rot_vc)
  • covariance tc(cvar_tc)
  • covariance wc(cvar_wc)
  • covaraince vc(cvar_vc)
  • Mean CO2 density(mean_c)
  • rotated covariance uc(cvar_rot_uc)


Back To Table of Contents



END OF DATA