Data Quality Reports for Session: 132186 User: horst1punz Completed: 12/15/2010


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D070801.1SGP/MWR/B1 - 23.8-GHz brightness temperature slightly highsgpmwrlosB1.b1, sgpmwrtipB1.a1, sgp5mwravgB1.c1
D090512.5SGP/MWR/B1 - Increased noise levelsgpmwrlosB1.b1, sgpmwrtipB1.a1


DQRID : D070801.1
Start DateStart TimeEnd DateEnd Time
06/19/2007160010/16/20090300
Subject:
SGP/MWR/B1 - 23.8-GHz brightness temperature slightly high
DataStreams:sgpmwrlosB1.b1, sgpmwrtipB1.a1, sgp5mwravgB1.c1
Description:
The radiometer was refurbished and tested at the central facility in 2007. During testing 
the 23.8-GHz brightness temperature was found to be about 1.5 K higher than the 
measurements of the C1 radiometer. 

On 6/19/07 the radiometer was installed at BF1. A comparison with model calculation showed 
that the measured 23.8-GHz brightness temperature is slightly higher than the model. 
This offset will affect the PWV retrieval that is on an average about 1.3 mm higher than the 
radiosonde measurements. The rms error of the retrieved PWV is about 1 mm higher than 
specified in the netcdf file.

On 10/16/2009 the radiometer was removed because of shut down of the boundary facility.
Measurements:sgpmwrtipB1.a1:
  • vaptip
  • tbskytip23

sgp5mwravgB1.c1:
  • Radiation, longwave, brightness temperature, 23.8 GHz(tbsky23)
  • Total water vapor along LOS path(vap)
  • 23tbsky

sgpmwrlosB1.b1:
  • Radiation, longwave, brightness temperature, 23.8 GHz(tbsky23)
  • Total water vapor along LOS path(vap)


Back To Table of Contents

DQRID : D090512.5
Start DateStart TimeEnd DateEnd Time
04/05/2009000009/01/20090000
Subject:
SGP/MWR/B1 - Increased noise level
DataStreams:sgpmwrlosB1.b1, sgpmwrtipB1.a1
Description:
The radiometer was experiencing intermittent increase in the noise level of the two 
channels. Although it looks like the radiometer was still able to calibrate, the increased 
noise level may have resulted in a reduced number of tip curves collected. The increased 
noise was intermittent and lasted for a few hours at a time.
Measurements:sgpmwrtipB1.a1:
  • vaptip
  • tbskytip31
  • liqtip
  • tbskytip23

sgpmwrlosB1.b1:
  • Total liquid water along LOS path(liq)
  • Radiation, longwave, brightness temperature, 23.8 GHz(tbsky23)
  • Total water vapor along LOS path(vap)
  • 31.4 GHz sky brightness temperature(tbsky31)


Back To Table of Contents



END OF DATA