Data Quality Reports for Session: 131319 User: dmfoper Completed: 11/03/2010


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D040331.2SGP/EBBR/E8 - AEM Replacementsgp5ebbrE8.b1, sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp30baebbrE8.c1


DQRID : D040331.2
Start DateStart TimeEnd DateEnd Time
04/05/2004000004/06/20041755
Subject:
SGP/EBBR/E8 - AEM Replacement
DataStreams:sgp5ebbrE8.b1, sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp30baebbrE8.c1
Description:
The AEM at E8 kept hanging in between home positions.

This DQR covers only the period during which the AEM was being
replaced.  

DQRs generally are not issued for AEMs that are not working
as qc flags indicate this clearly.
Measurements:sgp15ebbrE8.b1:
  • temp_air_right
  • temp_air_left

sgp30baebbrE8.c1:
  • hum_top
  • Heat flux, latent, best estimate(ecomb)
  • vp_bot
  • hum_bot
  • tair_top
  • thum_bot
  • thum_top
  • vp_top
  • tair_bot
  • bowen
  • Heat flux, latent, aerodynamic(ale)
  • Corrected sensible heat flux(h)
  • Heat flux, sensible, best estimate(hcomb)
  • Heat flux, sensible, aerodynamic(ah)
  • Heat flux, latent(e)

sgp5ebbrE8.b1:
  • rh_top_fraction
  • temp_trh_top
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_air_bottom
  • vapor_pressure_bottom
  • rh_bottom_fraction

sgp30ebbrE8.b1:
  • temp_trh_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_bottom
  • rh_top_fraction
  • temp_air_top
  • bowen_ratio
  • rh_bottom_fraction
  • vapor_pressure_top
  • temp_air_bottom
  • temp_trh_top
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)


Back To Table of Contents