Data Quality Reports for Session: 129443 User: tami1toto Completed: 08/03/2010


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D010403.37SGP/EBBR/E13 - E13 EBBR All Data Incorrectsgp15ebbrE13.b1, sgp30ebbrE13.b1, sgp5ebbrE13.b1
D010412.1SGP/EBBR/E13 - E13 EBBR Soil Temperature #4 Suspectsgp15ebbrE13.b1, sgp30ebbrE13.b1
D010605.5SGP EBBR E13 - E13 EBBR Soil T #4 Incorrectsgp15ebbrE13.b1, sgp30ebbrE13.b1
D021113.4SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR
Header
sgp30ebbrE12.b1, sgp30ebbrE13.b1, sgp30ebbrE15.b1, sgp30ebbrE20.b1, sgp30ebbrE22.b1,
sgp30ebbrE26.b1, sgp30ebbrE4.b1, sgp30ebbrE7.b1, sgp30ebbrE8.b1, sgp30ebbrE9.b1


DQRID : D010403.37
Start DateStart TimeEnd DateEnd Time
03/08/2000130003/08/20001301
Subject:
SGP/EBBR/E13 - E13 EBBR All Data Incorrect
DataStreams:sgp15ebbrE13.b1, sgp30ebbrE13.b1, sgp5ebbrE13.b1
Description:
Battery voltage was too low.  All data was incorrect.
Measurements:sgp15ebbrE13.b1:
  • home_signal
  • soil_temp_4_rr
  • temp_air_right
  • soil_heat_flow_1_mv
  • soil_temp_1_rr
  • soil_heat_flow_4_mv
  • atmos_pressure_mv
  • soil_moisture_4_r
  • temp_reference_rr
  • soil_moisture_2_r
  • wdir_vec_mean_mv
  • rh_left_mv
  • soil_temp_5_rr
  • temp_air_left
  • wspd_arith_mean
  • net_radiation_mv
  • soil_heat_flow_2_mv
  • soil_moisture_1_r
  • temp_trh_left_rr
  • soil_moisture_5_r
  • soil_heat_flow_3_mv
  • soil_temp_3_rr
  • soil_temp_2_rr
  • temp_trh_right_rr
  • soil_heat_flow_5_mv
  • soil_moisture_3_r
  • rh_right_mv

sgp5ebbrE13.b1:
  • temp_air_top
  • rh_bottom_fraction
  • vapor_pressure_top
  • wdir_vec_std
  • Barometric Pressure(atmos_pressure)
  • wdir_vec_mean
  • temp_trh_bottom
  • temp_reference
  • temp_trh_top
  • wspd_vec_mean
  • net_radiation
  • rh_top_fraction
  • vapor_pressure_bottom
  • home_signal
  • temp_air_bottom
  • wspd_arith_mean

sgp30ebbrE13.b1:
  • wspd_vec_mean
  • sensible_heat_flux
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • energy_storage_change_4
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • corr_soil_heat_flow_2
  • latent_heat_flux
  • corr_soil_heat_flow_1
  • wdir_vec_mean
  • soil_heat_flow_1
  • soil_moisture_1
  • soil_heat_flow_3
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_5
  • energy_storage_change_1
  • soil_moisture_3
  • energy_storage_change_3
  • soil_moisture_4
  • energy_storage_change_2
  • vapor_pressure_top
  • home_signal_15
  • wspd_arith_mean
  • net_radiation
  • temp_trh_bottom
  • home_signal_30
  • temp_air_bottom
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_avg
  • temp_air_top
  • temp_trh_top
  • Barometric Pressure(atmos_pressure)
  • temp_reference
  • soil_heat_capacity_1
  • soil_temp_2
  • soil_heat_capacity_5
  • soil_temp_1
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • soil_temp_5
  • soil_temp_4
  • soil_temp_3
  • wdir_vec_std
  • bowen_ratio
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_2
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • rh_top_fraction


Back To Table of Contents

DQRID : D010412.1
Start DateStart TimeEnd DateEnd Time
02/01/2000000012/31/20000000
Subject:
SGP/EBBR/E13 - E13 EBBR Soil Temperature #4 Suspect
DataStreams:sgp15ebbrE13.b1, sgp30ebbrE13.b1
Description:
Soil Temperature #4 produced noisy measurements, resulting in quantities
calculated from it to be of suspect quality.  This condition normally 
occurred early in the GMT day.  Sensible (h) and latent (e) heat fluxes
were not normally greatly affected.  Average surface heat flow was normally
slightly underestimated.
Measurements:sgp15ebbrE13.b1:
  • soil_temp_4_rr

sgp30ebbrE13.b1:
  • sensible_heat_flux
  • surface_soil_heat_flux_4
  • soil_heat_capacity_4
  • energy_storage_change_4
  • soil_temp_4
  • surface_soil_heat_flux_avg
  • latent_heat_flux


Back To Table of Contents

DQRID : D010605.5
Start DateStart TimeEnd DateEnd Time
09/29/1999000003/08/20011931
Subject:
SGP EBBR E13 - E13 EBBR Soil T #4 Incorrect
DataStreams:sgp15ebbrE13.b1, sgp30ebbrE13.b1
Description:
Soil Temperature #4 floated around, causing average soil heat flow
to sometimes be too small (resulting too small a sensible heat flux and
too large a latent heat flux) or too large (resulting in too large a 
sensible heat flux and too small a latent heat flux).  Investigation of
g4 will indicate when these conditions occurred and the likely effect on
sensible and latent heat fluxes.
Measurements:sgp15ebbrE13.b1:
  • soil_temp_4_rr

sgp30ebbrE13.b1:
  • sensible_heat_flux
  • surface_soil_heat_flux_4
  • energy_storage_change_4
  • soil_temp_4
  • surface_soil_heat_flux_avg
  • latent_heat_flux


Back To Table of Contents

DQRID : D021113.4
Start DateStart TimeEnd DateEnd Time
12/01/1993120006/18/20031159
Subject:
SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR 
Header
DataStreams:sgp30ebbrE12.b1, sgp30ebbrE13.b1, sgp30ebbrE15.b1, sgp30ebbrE20.b1, sgp30ebbrE22.b1,
sgp30ebbrE26.b1, sgp30ebbrE4.b1, sgp30ebbrE7.b1, sgp30ebbrE8.b1, sgp30ebbrE9.b1
Description:
The units for Soil Heat Capacity (cs1, cs2, cs3, cs4,
cs5) in the EBBR 30 minute netcdf header have been 
incorrect from the beginning of processing the data
into netcdf files.  The correct units are MJ/m^3/C.
   
This does not affect the data quality.

(NOTE: The actual begin date of some of these data streams
 is as early as 7/4/93.  This DQR applies to all 30m EBBR
 data.)
Measurements:sgp30ebbrE26.b1:
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_1

sgp30ebbrE9.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5

sgp30ebbrE7.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_5
  • soil_heat_capacity_3
  • soil_heat_capacity_4

sgp30ebbrE4.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5

sgp30ebbrE12.b1:
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_3

sgp30ebbrE15.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5

sgp30ebbrE22.b1:
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • soil_heat_capacity_1

sgp30ebbrE13.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2

sgp30ebbrE8.b1:
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_1

sgp30ebbrE20.b1:
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5
  • soil_heat_capacity_1


Back To Table of Contents



END OF DATA