Data Quality Reports for Session: 128468 User: lijun1ljr Completed: 06/16/2010


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D060414.6SGP/IRT/C1 - changed output range for new dataloggersgpirt10mC1.a1, sgpirt10mC1.b1
D060828.2SGP/IRT/C1 - UPS failingsgpirt10mC1.b1


DQRID : D060414.6
Start DateStart TimeEnd DateEnd Time
09/27/2001141609/27/20011456
Subject:
SGP/IRT/C1 - changed output range for new datalogger
DataStreams:sgpirt10mC1.a1, sgpirt10mC1.b1
Description:
The tower was lowered and the analog output parameters were changed at 14:45 to compensate 
for the recent change in data acquisition from an MFR logger to a CR10X.
Measurements:sgpirt10mC1.a1:
  • Surface Infra-Red Temperature, Standard Deviation(sfc_ir_temp_std)
  • Surface Infra-Red Temperature Minima(sfc_ir_temp_min)
  • Surface Infra-Red Temperature Maxima(sfc_ir_temp_max)
  • Effective Surface (Skin) Temperature(sfc_ir_temp)

sgpirt10mC1.b1:
  • Surface Infra-Red Temperature Maxima(sfc_ir_temp_max)
  • Surface Infra-Red Temperature, Standard Deviation(sfc_ir_temp_std)
  • Surface Infra-Red Temperature Minima(sfc_ir_temp_min)
  • Effective Surface (Skin) Temperature(sfc_ir_temp)


Back To Table of Contents

DQRID : D060828.2
Start DateStart TimeEnd DateEnd Time
08/26/2006085309/18/20061530
Subject:
SGP/IRT/C1 - UPS failing
DataStreams:sgpirt10mC1.b1
Description:
The IRT data were intermittently bad during this period due to a failing UPS. The problem 
was corrected by replacing the UPS.
Measurements:sgpirt10mC1.b1:
  • Battery Voltage(internal_voltage)
  • Surface Infra-Red Temperature Maxima(sfc_ir_temp_max)
  • Surface Infra-Red Temperature, Standard Deviation(sfc_ir_temp_std)
  • Surface Infra-Red Temperature Minima(sfc_ir_temp_min)
  • Effective Surface (Skin) Temperature(sfc_ir_temp)


Back To Table of Contents



END OF DATA