Data Quality Reports for Session: 128387 User: sbenson Completed: 06/12/2010


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D021211.10NSA/GNDRAD/C1 - Unreasonable/missing PIR data due to maintenancensagndrad60sC1.a1
D021211.11NSA/GNDRAD/C1 - Noisy PIR Datansagndrad60sC1.a1
D021211.8NSA/GNDRAD/C1 - PIR offlinensagndrad60sC1.a1
D021212.5NSA/GNDRAD/C1 - Bad PSP calibrations appliednsagndrad60sC1.a1
D080725.1NSA/GNDRAD/C1 - IRT not connectednsagndrad60sC1.a1
D080725.2NSA/GNDRAD/C1 - Reprocess: IRT scale factornsagndrad60sC1.a1
D080726.1NSA/GNDRAD/C1 - IRT failednsagndrad60sC1.a1
D990924.1NSA/GNDRAD/C1 - Reprocess: IRT insufficiently heatednsagndrad60sC1.a1


DQRID : D021211.10
Start DateStart TimeEnd DateEnd Time
01/19/1999183001/20/19992359
Subject:
NSA/GNDRAD/C1 - Unreasonable/missing PIR data due to maintenance
DataStreams:nsagndrad60sC1.a1
Description:
During this period, there are data gaps and the data that were
collected are unreasonable.  Instrument maintenance was being
performed
Measurements:nsagndrad60sC1.a1:
  • PSP1 unshaded mean(psp1_mean)
  • PSP1 unshaded standard deviation(psp1_sd)
  • Net Radiation, Standard Deviation(net_std)
  • Net Radiation, Maxima(net_max)
  • PSP1 unshaded minimum(psp1_min)
  • PSP1 unshaded maximum(psp1_max)
  • PIR1 unshaded standard deviation(pir1_sd)
  • PIR1 unshaded maximum(pir1_max)
  • PIR1 unshaded minimum(pir1_min)
  • NET mean(net_mean)
  • PIR1 unshaded mean(pir1_mean)
  • Net Radiation, Minima(net_min)
  • Net Radiation(net)
  • NET standard deviation(net_sd)


Back To Table of Contents

DQRID : D021211.11
Start DateStart TimeEnd DateEnd Time
09/01/1998000002/28/19992359
Subject:
NSA/GNDRAD/C1 - Noisy PIR Data
DataStreams:nsagndrad60sC1.a1
Description:
During the period referenced, the ground PIR was noisy in comparison to the sky PIR data.  
At the end of November, the noise increased to roughly 10 W/m2 from peak to peak.  After 
12/23/98, the noise decreased in amplitude but still had noisy patterns.  

On 01/17-18/99, there was an increase again in the noise level (4 GMT 01/17 - 5 GMT 
01/18). During this period the gndrad IRT data also exhibited noise patterns (the IRT was not 
operational).

In February, the instrument exhibited large noise variations again.  On 02/16, a wiring 
problem was corrected and the noise dropped back to 1-5 W/m2.  However, the noise levels 
began to increase again.
Measurements:nsagndrad60sC1.a1:
  • PIR1 unshaded maximum(pir1_max)
  • PIR1 unshaded standard deviation(pir1_sd)
  • PIR1 unshaded minimum(pir1_min)
  • PIR1 unshaded mean(pir1_mean)


Back To Table of Contents

DQRID : D021211.8
Start DateStart TimeEnd DateEnd Time
02/16/1999003002/16/19992000
02/17/1999000002/17/19990100
Subject:
NSA/GNDRAD/C1 - PIR offline
DataStreams:nsagndrad60sC1.a1
Description:
The PIR was taken off line during this period; data recorded 
              during this period are garbage.
Measurements:nsagndrad60sC1.a1:
  • PIR1 unshaded maximum(pir1_max)
  • PIR1 unshaded standard deviation(pir1_sd)
  • PIR1 unshaded minimum(pir1_min)
  • PIR1 unshaded mean(pir1_mean)


Back To Table of Contents

DQRID : D021212.5
Start DateStart TimeEnd DateEnd Time
01/21/1999000002/09/19992359
Subject:
NSA/GNDRAD/C1 - Bad PSP calibrations applied
DataStreams:nsagndrad60sC1.a1
Description:
The ground radiation data are bad during this period due to 
              erroneous calibration factors in the logger configuration file.
Measurements:nsagndrad60sC1.a1:
  • PSP1 unshaded mean(psp1_mean)
  • PSP1 unshaded standard deviation(psp1_sd)
  • Net Radiation, Standard Deviation(net_std)
  • Net Radiation, Maxima(net_max)
  • PSP1 unshaded minimum(psp1_min)
  • PSP1 unshaded maximum(psp1_max)
  • PIR1 unshaded standard deviation(pir1_sd)
  • PIR1 unshaded maximum(pir1_max)
  • PIR1 unshaded minimum(pir1_min)
  • NET mean(net_mean)
  • PIR1 unshaded mean(pir1_mean)
  • Net Radiation, Minima(net_min)
  • Net Radiation(net)
  • NET standard deviation(net_sd)


Back To Table of Contents

DQRID : D080725.1
Start DateStart TimeEnd DateEnd Time
12/10/1998220001/20/19990059
Subject:
NSA/GNDRAD/C1 - IRT not connected
DataStreams:nsagndrad60sC1.a1
Description:
The IRT was unplugged from the Zeno data logger on 12/10/1998 for a interference test and 
when it was plugged back in on 12/22, the connector at the data logger was damaged. The 
data logger and connecter were replaced on 1/20/1999.
Measurements:nsagndrad60sC1.a1:
  • Surface Infra-Red Temperature Maxima(sfc_ir_temp_max)
  • Surface Infra-Red Temperature, Standard Deviation(sfc_ir_temp_std)
  • Effective Surface (Skin) Temperature(sfc_ir_temp)
  • Surface Infra-Red Temperature Minima(sfc_ir_temp_min)


Back To Table of Contents

DQRID : D080725.2
Start DateStart TimeEnd DateEnd Time
01/20/1999010003/04/19991506
Subject:
NSA/GNDRAD/C1 - Reprocess: IRT scale factor
DataStreams:nsagndrad60sC1.a1
Description:
The IRT scale factors in the data logger were incorrectly set to m = 100 degC/V, b = -60 
degC. They were corrected to 25 degC/V and -50 degC.

Correct with: IRT(C) = (IRT_bad+60C)*(25/100) - 50C
Measurements:nsagndrad60sC1.a1:
  • Surface Infra-Red Temperature Maxima(sfc_ir_temp_max)
  • Surface Infra-Red Temperature, Standard Deviation(sfc_ir_temp_std)
  • Effective Surface (Skin) Temperature(sfc_ir_temp)
  • Surface Infra-Red Temperature Minima(sfc_ir_temp_min)


Back To Table of Contents

DQRID : D080726.1
Start DateStart TimeEnd DateEnd Time
02/09/1999213803/03/19991200
Subject:
NSA/GNDRAD/C1 - IRT failed
DataStreams:nsagndrad60sC1.a1
Description:
The IRT failed and was replaced with one installed inside an insulated enclosure.
Measurements:nsagndrad60sC1.a1:
  • Surface Infra-Red Temperature Maxima(sfc_ir_temp_max)
  • Surface Infra-Red Temperature, Standard Deviation(sfc_ir_temp_std)
  • Effective Surface (Skin) Temperature(sfc_ir_temp)
  • Surface Infra-Red Temperature Minima(sfc_ir_temp_min)


Back To Table of Contents

DQRID : D990924.1
Start DateStart TimeEnd DateEnd Time
04/06/1998215612/22/20002020
Subject:
NSA/GNDRAD/C1 - Reprocess: IRT insufficiently heated
DataStreams:nsagndrad60sC1.a1
Description:
IRT had insufficient heating to maintain an internal reference temperature above 0 degrees 
C.  Measurements of surface temperature were over-estimated when instrument was below 
freezing.

Data will be reprocessed, but users can correct data using the following correction 
factor:

If T_reference < -5?C, then

  IRT_corrected = (IRT_original - 32.993K)/0.87238

where T_reference can be estimated with the ambient temperature (e.g. 
inst_up_long_hemisp_dome_temp or inst_up_long_dome_temp)
Measurements:nsagndrad60sC1.a1:
  • IRT1 maximum(irt1_max)
  • IRT1 minimum(irt1_min)
  • IRT1 standard deviation(irt1_sd)
  • IRT1 mean(irt1_mean)


Back To Table of Contents



END OF DATA