Data Quality Reports for Session: 128385 User: sbenson Completed: 06/12/2010


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D080222.3NSA/SKYRAD/C1 - IRT mirror heater failurensaskyrad20sC1.a0, nsaskyrad60sC1.b1
D080418.1NSA/SKYRAD/C1 - Direct and Diffuse incorrectnsaskyrad20sC1.a0, nsaskyrad60sC1.b1
D080630.1NSA/SKYRAD/C1 - Tracker inoperativensaskyrad20sC1.a0, nsaskyrad60sC1.b1


DQRID : D080222.3
Start DateStart TimeEnd DateEnd Time
12/16/2007000002/11/20081135
Subject:
NSA/SKYRAD/C1 - IRT mirror heater failure
DataStreams:nsaskyrad20sC1.a0, nsaskyrad60sC1.b1
Description:
The heater of the IRT gold mirror failed due to a broken wire (that probably occurred on 
12/13 during maintenance of the solar tracker) allowing snow and frost to accumulate on 
the mirror until it was cleared during daily preventative maintenance. The problem was 
corrected when the heater wires were replaced.
Measurements:nsaskyrad60sC1.b1:
  • Sky Infra Red Temperature Minima(sky_ir_temp_min)
  • Standard Deviation of Sky Infra Red Temperature(sky_ir_temp_std)
  • Sky Infra Red Temperature Maxima(sky_ir_temp_max)
  • Sky Infra-Red Temperature(sky_ir_temp)

nsaskyrad20sC1.a0:
  • Instantaneous Sky/Cloud Infrared(inst_sky_ir_signal)


Back To Table of Contents

DQRID : D080418.1
Start DateStart TimeEnd DateEnd Time
04/17/2008063204/23/20081815
Subject:
NSA/SKYRAD/C1 - Direct and Diffuse incorrect
DataStreams:nsaskyrad20sC1.a0, nsaskyrad60sC1.b1
Description:
The short_direct_normal (NIP) instrument and cable were damaged by tracker rewind 
malfunction. Tracker and NIP replaced on 4/22 2200GMT but tracker not operational until 4/23 
1815GMT.  Thus, down_short_diffuse_hemisp (8-48) was not shaded 4/22 to 4/23.

Do not use 8-48 data from 4/22 to 4/23. NIP data is not recoverable during entire time but 
can be estimated using component sum for each 1 minute data: Direct = (global - 
diffuse)/cos(zenith angle)
Measurements:nsaskyrad60sC1.b1:
  • Shortwave Direct Normal Irradiance, Pyrgeometer(short_direct_normal)
  • Downwelling Shortwave Diffuse Hemispheric Irradiance, Ventilated Pyranometer(down_short_diffuse_hemisp)
  • Downwelling Shortwave Diffuse Hemispheric Irradiance, Ventilated Pyranometer,
    Maxima(down_short_diffuse_hemisp_max)
  • Shortwave Direct Normal Irradiance, Pyrgeometer, Standard Deviation(short_direct_normal_std)
  • Downwelling Shortwave Hemispheric Irradiance, Pyranometer, Standard Deviation(down_short_diffuse_hemisp_std)
  • Shortwave Direct Normal Irradiance, Pyrgeometer, Minima(short_direct_normal_min)
  • Shortwave Direct Normal Irradiance, Pyrgeometer, Maxima(short_direct_normal_max)
  • Downwelling Shortwave Diffuse Hemispheric Irradiance, Ventilated Pyranometer,
    Minima(down_short_diffuse_hemisp_min)

nsaskyrad20sC1.a0:
  • Instantaneous Uncorrected Downwelling Shortwave Diffuse, Shaded Pyranometer
    Thermopile Voltage(inst_diffuse)
  • Instantaneous Direct Normal Shortwave Irradiance, Pyheliometer Thermopile
    Voltage(inst_direct_normal)


Back To Table of Contents

DQRID : D080630.1
Start DateStart TimeEnd DateEnd Time
06/27/2008200006/30/20081740
Subject:
NSA/SKYRAD/C1 - Tracker inoperative
DataStreams:nsaskyrad20sC1.a0, nsaskyrad60sC1.b1
Description:
Tracker stopped working at this site during the time range specified. Reason for failure 
is unknown.  Tracker power cycled and restarted by maintenance 06/30 2008 1740 GMT.

The short_direct_normal (NIP) and down_short_diffuse_hemisp (8-48) data are bad during 
this time.  Data are not recoverable.
Measurements:nsaskyrad60sC1.b1:
  • Downwelling Shortwave Diffuse Hemispheric Irradiance, Ventilated Pyranometer(down_short_diffuse_hemisp)
  • Downwelling Shortwave Diffuse Hemispheric Irradiance, Ventilated Pyranometer,
    Maxima(down_short_diffuse_hemisp_max)
  • Downwelling Shortwave Hemispheric Irradiance, Pyranometer, Standard Deviation(down_short_diffuse_hemisp_std)
  • Downwelling Shortwave Diffuse Hemispheric Irradiance, Ventilated Pyranometer,
    Minima(down_short_diffuse_hemisp_min)

nsaskyrad20sC1.a0:
  • Instantaneous Uncorrected Downwelling Shortwave Diffuse, Shaded Pyranometer
    Thermopile Voltage(inst_diffuse)
  • Instantaneous Direct Normal Shortwave Irradiance, Pyheliometer Thermopile
    Voltage(inst_direct_normal)


Back To Table of Contents