Data Quality Reports for Session: 127689 User: julia1flah Completed: 05/11/2010


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D051216.2SGP/ECOR/E14 - Flux Measurements Incorrectsgp30ecorE14.b1
D070514.2SGP/ECOR/E14 - IRGA Temperature Incorrect or Missingsgp30ecorE14.b1


DQRID : D051216.2
Start DateStart TimeEnd DateEnd Time
11/04/2005133011/17/20051630
12/01/2005193012/13/20051630
01/24/2006150002/13/20061930
05/05/2006210006/13/20061400
07/07/2006193007/14/20061500
Subject:
SGP/ECOR/E14 - Flux Measurements Incorrect
DataStreams:sgp30ecorE14.b1
Description:
The ECOR datastream was corrupted; this happens when the ECOR program produces a 
datastream of the wrong length (i.e., leaves one or more measurements out).

Fluxes and some other measurements are incorrect.

Reprocessing will not correct this problem; the raw data are corrupted.
Measurements:sgp30ecorE14.b1:
  • Water vapor density (q)(mean_q)
  • h(h)
  • average atmospheric pressure (IGRA internal sensor)(atm_pres)
  • mean co2 concentration (c)(mean_c)
  • average temperature (IGRA internal sensor)(temp_irga)
  • CO2 flux(fc)
  • latent heat flux(lv_e)


Back To Table of Contents

DQRID : D070514.2
Start DateStart TimeEnd DateEnd Time
05/09/2007130005/19/20071700
Subject:
SGP/ECOR/E14 - IRGA Temperature Incorrect or Missing
DataStreams:sgp30ecorE14.b1
Description:
The temp_irga was too large 05/09/07 1300 GMT - 05/10/07 2000 GMT.

The temp_irga was flat lined at 49.96 C 05/10/07 2030 GMT - 05/17/07 2000 GMT.  

The temp_irga was missing 05/17/07 2030 GMT - 05/19/07 1700 GMT.
Measurements:sgp30ecorE14.b1:
  • average temperature (IGRA internal sensor)(temp_irga)


Back To Table of Contents



END OF DATA