Data Quality Reports for Session: 126721 User: tami1toto Completed: 03/10/2010


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D020702.3SGP/SMOS/E21 - Reprocess: Errors in Global Metadatasgp1440smosE21.a0, sgp1smosE21.a0, sgp30smosE21.a1
D040319.6SGP/SMOS/E24 - 6-month Calibration Checkssgp1440smosE24.a0, sgp1smosE24.a0, sgp30smosE24.a1
D050421.11SGP/SMOS/E4 - Reprocess: Wind direction offsetsgp1smosE4.a0, sgp30smosE4.a1
D050421.8SGP/SMOS/E3 - Reprocess: Wind direction offsetsgp1smosE3.a0, sgp30smosE3.a1
D050422.3SGP/SMOS/E6 - Reprocess: Wind direction offsetsgp1smosE6.a0, sgp30smosE6.a1
D050422.6SGP/SMOS/E7 - Reprocess: Wind direction offsetsgp1smosE7.a0, sgp30smosE7.a1


DQRID : D020702.3
Start DateStart TimeEnd DateEnd Time
08/20/1999000003/31/20012359
Subject:
SGP/SMOS/E21 - Reprocess: Errors in Global Metadata
DataStreams:sgp1440smosE21.a0, sgp1smosE21.a0, sgp30smosE21.a1
Description:
The netcdf files for SMOS.E21 incorrectly list sensor heights at E21, Okmulgee
as being 10m for winds, 2m for temp, RH and vapor pressure, and 1m for barometric
pressure.  The Okmulgee site is a forested site and these sensors are mounted on
a tower above the canopy.  The actual sensor heights are 18m for winds, 17m for
temp, RH and vapor pressure, and 19m for barometric pressure which corresponds
to 3.7m, 2.7m, and 4.7m above average canopy height respectively.
Measurements:sgp1440smosE21.a0:
  • Time of Maximum Barometric Pressure(time_max_bar_pres)
  • Maximum Barometric Pressure(max_bar_pres)
  • Time of Minimum Temperature(time_min_temp)
  • Minimum Relative Humidity(min_rh)
  • Time of Maximum Relative Humidity(time_max_rh)
  • Minimum of Wind speed(min_wspd)
  • Maximum Vapor Pressure(max_vap_pres)
  • Maximum Temperature(max_temp)
  • Time of Maximum Wind Speed(time_max_wspd)
  • Time of Maximum Vapor Pressure(time_max_vap_pres)
  • Time of Minimum Barometric Pressure(time_min_bar_pres)
  • Maximum Relative Humidity(max_rh)
  • Minimum Temperature(min_temp)
  • Time of Minimum Wind Speed(time_min_wspd)
  • Time of Minimum Relative Humidity(time_min_rh)
  • Time of Minimum Vapor Pressure(time_min_vap_pres)
  • Minimum Vapor Pressure(min_vap_pres)
  • Minimum Barometric Pressure(min_bar_pres)
  • maximum wind speed (gusts)(max_wspd)
  • Time of Maximum Temperature(time_max_temp)

sgp1smosE21.a0:
  • Mean Wind Speed(wspd)
  • Relative humidity inside the instrument enclosure(rh)
  • barometric pressure(bar_pres)
  • Beam 0 Temperature(temp)
  • Standard Deviation of wind direction(sd_deg)
  • Unit Vector Wind Direction(wdir)
  • Vapor Pressure (kiloPascals)(vap_pres)
  • Wind Speed (vector averaged)(wspd_va)

sgp30smosE21.a1:
  • Relative humidity inside the instrument enclosure(rh)
  • Standard Deviation of Barometric Pressure(sd_bar_pres)
  • Standard Deviation of Air Temperature(sd_temp)
  • Wind Speed (vector averaged)(wspd_va)
  • Standard Deviation of Vapor Pressure(sd_vap_pres)
  • Vapor Pressure (kiloPascals)(vap_pres)
  • Standard Deviation of wind direction(sd_deg)
  • Mean Wind Speed(wspd)
  • Standard Deviation of Relative Humidity(sd_rh)
  • Unit Vector Wind Direction(wdir)
  • Beam 0 Temperature(temp)
  • Standard Deviation of Wind Speed(sd_wspd)
  • barometric pressure(bar_pres)


Back To Table of Contents

DQRID : D040319.6
Start DateStart TimeEnd DateEnd Time
10/12/1995135510/12/19951500
04/24/1996163004/24/19961830
11/07/1996155511/07/19961645
04/23/1997193004/23/19972130
10/21/1997160010/21/19972030
05/19/1998193005/19/19982200
11/19/1998144511/19/19981620
03/23/1999210003/23/19992300
12/16/1999165512/16/19991855
03/07/2000170003/07/20001855
05/18/2000155005/18/20001700
10/05/2000164810/05/20001725
Subject:
SGP/SMOS/E24 - 6-month Calibration Checks
DataStreams:sgp1440smosE24.a0, sgp1smosE24.a0, sgp30smosE24.a1
Description:
During the time periods specified, the SMOS.E24 tower was
lowered for 6-month Calibration Checks.  During these times 
wind data are incorrect and temperature and humidity data 
may be incorrect.

Note, exact times when tower was down or maintenance was
being performed is sometimes unknown.  Users should use
the remaining data from these days with caution.
Measurements:sgp30smosE24.a1:
  • Beam 0 Temperature(temp)
  • Unit Vector Wind Direction(wdir)
  • Mean Wind Speed(wspd)
  • barometric pressure(bar_pres)
  • Vapor Pressure (kiloPascals)(vap_pres)
  • Standard Deviation of Wind Speed(sd_wspd)
  • Standard Deviation of Vapor Pressure(sd_vap_pres)
  • Standard Deviation of wind direction(sd_deg)
  • Relative humidity inside the instrument enclosure(rh)
  • Wind Speed (vector averaged)(wspd_va)
  • Standard Deviation of Air Temperature(sd_temp)
  • Standard Deviation of Barometric Pressure(sd_bar_pres)
  • Standard Deviation of Relative Humidity(sd_rh)

sgp1smosE24.a0:
  • Relative humidity inside the instrument enclosure(rh)
  • Unit Vector Wind Direction(wdir)
  • barometric pressure(bar_pres)
  • Beam 0 Temperature(temp)
  • Vapor Pressure (kiloPascals)(vap_pres)
  • Standard Deviation of wind direction(sd_deg)
  • Mean Wind Speed(wspd)
  • Wind Speed (vector averaged)(wspd_va)

sgp1440smosE24.a0:
  • Maximum Barometric Pressure(max_bar_pres)
  • Minimum Barometric Pressure(min_bar_pres)
  • Time of Minimum Barometric Pressure(time_min_bar_pres)
  • Time of Maximum Vapor Pressure(time_max_vap_pres)
  • Time of Minimum Temperature(time_min_temp)
  • Time of Minimum Relative Humidity(time_min_rh)
  • Time of Minimum Vapor Pressure(time_min_vap_pres)
  • Time of Maximum Temperature(time_max_temp)
  • maximum wind speed (gusts)(max_wspd)
  • Maximum Vapor Pressure(max_vap_pres)
  • Minimum Temperature(min_temp)
  • Maximum Relative Humidity(max_rh)
  • Minimum Vapor Pressure(min_vap_pres)
  • Time of Maximum Relative Humidity(time_max_rh)
  • Maximum Temperature(max_temp)
  • Time of Minimum Wind Speed(time_min_wspd)
  • Time of Maximum Wind Speed(time_max_wspd)
  • Minimum Relative Humidity(min_rh)
  • Time of Maximum Barometric Pressure(time_max_bar_pres)
  • Minimum of Wind speed(min_wspd)


Back To Table of Contents

DQRID : D050421.11
Start DateStart TimeEnd DateEnd Time
03/30/1995000003/31/20012359
Subject:
SGP/SMOS/E4 - Reprocess: Wind direction offset
DataStreams:sgp1smosE4.a0, sgp30smosE4.a1
Description:
When the SGP.E4 SMOS tower was installed it was not aligned
properly resulting in a 7 degree offset.  On 3/9/05, the
datalogger program was modifed to correct for this offset.
Measurements:sgp1smosE4.a0:
  • Unit Vector Wind Direction(wdir)

sgp30smosE4.a1:
  • Unit Vector Wind Direction(wdir)


Back To Table of Contents

DQRID : D050421.8
Start DateStart TimeEnd DateEnd Time
12/12/1995000003/31/20012359
Subject:
SGP/SMOS/E3 - Reprocess: Wind direction offset
DataStreams:sgp1smosE3.a0, sgp30smosE3.a1
Description:
When the SGP.E3 SMOS tower was installed it was not aligned
properly resulting in a 7 degree offset.  On 3/9/05, the
datalogger program was modified to correct for this offset.
Measurements:sgp1smosE3.a0:
  • Unit Vector Wind Direction(wdir)

sgp30smosE3.a1:
  • Unit Vector Wind Direction(wdir)


Back To Table of Contents

DQRID : D050422.3
Start DateStart TimeEnd DateEnd Time
12/21/1995000003/31/20012359
Subject:
SGP/SMOS/E6 - Reprocess: Wind direction offset
DataStreams:sgp1smosE6.a0, sgp30smosE6.a1
Description:
When the SGP.E6 SMOS tower was installed it was not aligned
properly resulting in a 7 degree offset.  On 3/10/05, the
datalogger program was modified to correct for this offset.
Measurements:sgp30smosE6.a1:
  • Unit Vector Wind Direction(wdir)

sgp1smosE6.a0:
  • Unit Vector Wind Direction(wdir)


Back To Table of Contents

DQRID : D050422.6
Start DateStart TimeEnd DateEnd Time
02/24/1995000003/31/20012359
Subject:
SGP/SMOS/E7 - Reprocess: Wind direction offset
DataStreams:sgp1smosE7.a0, sgp30smosE7.a1
Description:
When the SGP.E7 SMOS tower was installed it was not aligned
properly resulting in a 6 degree offset.  On 3/08/05, the
datalogger program was modified to correct for this offset.
Measurements:sgp30smosE7.a1:
  • Unit Vector Wind Direction(wdir)

sgp1smosE7.a0:
  • Unit Vector Wind Direction(wdir)


Back To Table of Contents



END OF DATA