Data Quality Reports for Session: 125493 User: vghate Completed: 01/27/2010


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D070412.1FKB/MET/M1 - Optical Rain Gauge Data IncorrectfkbmetM1.b1
D070412.2FKB/MET/M1 - ORG Data incorrect during calibrationfkbmetM1.b1
D070417.1FKB/MET/M1 - Optical Rain Gauge Data IncorrectfkbmetM1.b1
D080116.25FKB/MET/M1 - Optical Rain Gage Reporting Precip ConstantlyfkbmetM1.b1
D080428.5FKB/MET/M1 - Reprocess: ORG Data has very small rainrate valuesfkbmetM1.b1
D081022.9FKB/MET/M1 - Wind Speed data contain offset due to induced voltagefkbmetM1.b1


DQRID : D070412.1
Start DateStart TimeEnd DateEnd Time
03/17/2007000003/17/20070600
04/02/2007000004/02/20070800
04/03/2007030004/03/20070800
04/04/2007230004/05/20070900
04/06/2007010004/06/20070800
04/07/2007000004/07/20070700
04/09/2007000004/09/20070800
04/10/2007000004/10/20070700
04/11/2007000004/11/20070700
Subject:
FKB/MET/M1 - Optical Rain Gauge Data Incorrect
DataStreams:fkbmetM1.b1
Description:
The Optical Raingauge (ORG) data was incorrect during the listed times.  Ice/frost was 
forming on the lenses causing the ORG to believe there was precipitation occurring.
Measurements:fkbmetM1.b1:
  • Precipitation rate standard deviation(precip_rate_sd)
  • Precipitation rate mean(precip_rate_mean)
  • Precipitation rate maximum(precip_rate_max)
  • Precipitation rate minimum(precip_rate_min)


Back To Table of Contents

DQRID : D070412.2
Start DateStart TimeEnd DateEnd Time
04/08/2007073604/08/20070745
Subject:
FKB/MET/M1 - ORG Data incorrect during calibration
DataStreams:fkbmetM1.b1
Description:
The ORG data was incorrect during calibration checks.  The check mimics a precipiation 
event so the precip amounts that were collected were not actually measured.
Measurements:fkbmetM1.b1:
  • Precipitation rate standard deviation(precip_rate_sd)
  • Precipitation rate mean(precip_rate_mean)
  • Precipitation rate maximum(precip_rate_max)
  • Precipitation rate minimum(precip_rate_min)


Back To Table of Contents

DQRID : D070417.1
Start DateStart TimeEnd DateEnd Time
04/05/2007000004/28/20072359
Subject:
FKB/MET/M1 - Optical Rain Gauge Data Incorrect
DataStreams:fkbmetM1.b1
Description:
Precipitation was being reported on days with no rain.  Problems with the grounding and 
the orientation of the receiver facing south (sunlight in the optics) caused erroneous 
readings.
Measurements:fkbmetM1.b1:
  • Precipitation rate standard deviation(precip_rate_sd)
  • Precipitation rate mean(precip_rate_mean)
  • ORG carrier mean(org_carrier_mean)
  • Precipitation rate maximum(precip_rate_max)
  • Precipitation rate minimum(precip_rate_min)


Back To Table of Contents

DQRID : D080116.25
Start DateStart TimeEnd DateEnd Time
12/15/2007030012/31/20072359
Subject:
FKB/MET/M1 - Optical Rain Gage Reporting Precip Constantly
DataStreams:fkbmetM1.b1
Description:
During the time period listed the ORG reported precip consistently.  Reason unknown as 
deployment ended before resolution of problem.
Measurements:fkbmetM1.b1:
  • Precipitation rate standard deviation(precip_rate_sd)
  • Precipitation rate mean(precip_rate_mean)
  • Precipitation rate maximum(precip_rate_max)
  • Precipitation rate minimum(precip_rate_min)


Back To Table of Contents

DQRID : D080428.5
Start DateStart TimeEnd DateEnd Time
03/14/2007000012/31/20072359
Subject:
FKB/MET/M1 - Reprocess: ORG Data has very small rainrate values
DataStreams:fkbmetM1.b1
Description:
The ORG data is collected via analog signal and not digital.  Therefore, we
   continuously collect data even when no rain is occurring.  We also capture
   small events such as leaves, large bugs, dust, etc blowing through the
   measurement path.  Because this discrete event occurs quickly the value is
   usually captured for 1 or 2 seconds.  This value is then averaged to the
   minute producing rainrate on the order of .009 mm/hr or less.  These values
   are not indicative of rain and should be removed from the record or summing
   over long periods can bias the climate record.  We are reprocessing the data
   to remove these small values and are adjusting the collection program to
   remove them before ingest.
Measurements:fkbmetM1.b1:
  • Precipitation rate standard deviation(precip_rate_sd)
  • Precipitation rate mean(precip_rate_mean)
  • Precipitation rate maximum(precip_rate_max)
  • Precipitation rate minimum(precip_rate_min)


Back To Table of Contents

DQRID : D081022.9
Start DateStart TimeEnd DateEnd Time
03/01/2007000001/01/20082359
Subject:
FKB/MET/M1 - Wind Speed data contain offset due to induced voltage
DataStreams:fkbmetM1.b1
Description:
The marine model of the RM Young wind sensor needs twisted pair shielded cable.  The 
manufacturer did not originally supply the pigtail with twisted pair shielded cable.  Use of 
twisted pair shielded cable for the rest of the cable run to the logger was also not 
specified.  This caused an induced voltage in the wind speed line from the wind direction 
excitation.  The induced voltage varied from sensor to sensor and probably changed anytime 
the cable was replaced or parts of the wind sensor were repaired or replaced. The induced 
voltage has been seen to vary from 0.15 m/s to as much as 1.08 m/s.
Measurements:fkbmetM1.b1:
  • Wind speed arithmetic standard deviation(wind_spd_arith_sd)
  • Wind speed arithmetic average(wind_spd_arith_avg)
  • Wind speed arithmetic maximum(wind_spd_arith_max)
  • Wind speed arithmetic minimum(wind_spd_arith_min)
  • Vector-averaged Wind Speed(wind_spd_vec_avg)


Back To Table of Contents