Data Quality Reports for Session: 124527 User: sbenson Completed: 11/25/2009


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D020620.61TWP/C1 - Incorrect elevation reported in Manus Datatwpgndrad20sC1.a1, twpgndrad60sC1.a1, twpgndrad60sC1.b1, twpsmet60sC1.a1, twpsmet60sC1.b1
D050421.6TWP/SMET/C1 - Negative rainfall ratestwpsmet60sC1.b1
D060817.3TWP/SMET/C1 - Reprocess: Barometric pressure units changetwpsmet60sC1.b1
D061011.2TWP/SMET/C1 - Reprocess: Tipping bucket rain gauge addedtwpsmet60sC1.b1
D080922.3TWP/SMET/C1 - Missing datatwpsmet60sC1.b1
D081022.3TWP/SMET/C1 - Wind Speed data contain offset due to induced voltagetwpsmet60sC1.b1


DQRID : D020620.61
Start DateStart TimeEnd DateEnd Time
10/10/1996000106/22/20002359
Subject:
TWP/C1 - Incorrect elevation reported in Manus Data
DataStreams:twpgndrad20sC1.a1, twpgndrad60sC1.a1, twpgndrad60sC1.b1, twpsmet60sC1.a1, twpsmet60sC1.b1
Description:
(From Bill Clements) We have been using 6m MSL as the station
elevation of Momote (Manus).  This was based on information
posted near the station barometer in the Momote Weather Service
Office.  It turns out that the official WMO station elevation
for Momote is 4m MSL and the upper air elevation is 5m MSL.

All Manus instruments except the sonde station are at 4m MSL.
The sonde launching station is at 5m MSL.
Measurements:twpgndrad20sC1.a1:
  • Dummy altitude for Zeb(alt)

twpgndrad60sC1.b1:
  • Dummy altitude for Zeb(alt)

twpsmet60sC1.b1:
  • Dummy altitude for Zeb(alt)

twpgndrad60sC1.a1:
  • Dummy altitude for Zeb(alt)

twpsmet60sC1.a1:
  • Dummy altitude for Zeb(alt)


Back To Table of Contents

DQRID : D050421.6
Start DateStart TimeEnd DateEnd Time
10/09/1996000003/09/20042243
Subject:
TWP/SMET/C1 - Negative rainfall rates
DataStreams:twpsmet60sC1.b1
Description:
Due to limitations of the Zeno dataloggers all voltage measurements
from the optical rain gauge (ORG) were converted to rainfall rates. 
This resulted in negative values for rain rates.  Any value below 0.10 mm/hr should be 
considered to be 0 mm/hr.  New dataloggers 
alleviated this problem.  New loggers were installed 03/09/2004 @ 2243 GMT.
Measurements:twpsmet60sC1.b1:
  • Precipitation mean(precip_mean)
  • Precipitation maximum(precip_max)
  • Precipitation standard deviation(precip_sd)
  • precipitation minimum(precip_min)


Back To Table of Contents

DQRID : D060817.3
Start DateStart TimeEnd DateEnd Time
10/09/1996000008/02/20041911
Subject:
TWP/SMET/C1 - Reprocess: Barometric pressure units change
DataStreams:twpsmet60sC1.b1
Description:
Barometric pressure data during this time period is reported in hPa.  After this time, the 
data have been converted to kPa to standardize the measurement units among ARM sites and 
to conform to accepted standard units determined by the scientific community.
Measurements:twpsmet60sC1.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D061011.2
Start DateStart TimeEnd DateEnd Time
10/09/1996000010/17/20060000
Subject:
TWP/SMET/C1 - Reprocess: Tipping bucket rain gauge added
DataStreams:twpsmet60sC1.b1
Description:
A tipping bucket rain gauge was added to the TWP.C1 SMET suite of instruments on 20061017. 
 Effective 20060926, two new variables (count and rain amount) were added to the end of 
the twpsmet60sC1.b1 datastream.  Between 9/26 and 10/17, the data for these two variables 
are filled with zeros.  Users should not use the data during this period as the zeros 
are not representative of the rain fall at the site.  When reprocessing of this datastream 
occurs these variables will be added for the 19961009-20060926 and data from 
19961009-20061017 will be filled with -9999 (missing).
Measurements:twpsmet60sC1.b1:
  • base time(base_time)


Back To Table of Contents

DQRID : D080922.3
Start DateStart TimeEnd DateEnd Time
06/04/1997055306/11/19970653
09/03/1999033209/10/19990406
10/01/1999093210/18/19990000
03/13/2000094403/15/20001533
03/18/2000202503/22/20001629
06/17/2000072906/21/20002226
08/09/2000230508/11/20001542
08/12/2000155208/14/20001807
10/15/2000182310/17/20000016
10/18/2000132610/20/20000014
10/24/2000160110/26/20002332
10/31/2000191411/02/20000032
11/05/2000051711/07/20002333
08/16/2002092908/22/20020315
10/27/2002085910/31/20020114
Subject:
TWP/SMET/C1 - Missing data
DataStreams:twpsmet60sC1.b1
Description:
Data are missing and unrecoverable.
Measurements:twpsmet60sC1.b1:
  • Battery Voltage(internal_voltage)
  • Dummy altitude for Zeb(alt)
  • Vapor pressure mean(vappress_mean)
  • Lower sensor, wind direction standard deviation(lo_dir_sd)
  • base time(base_time)
  • Lower sensor, wind speed standard deviation(lo_spd_sd)
  • Upper sensor, wind speed minimum(up_spd_min)
  • Precipitation standard deviation(precip_sd)
  • Upper sensor, wind speed standard deviation(up_spd_sd)
  • Logger panel temperature(logger_temp)
  • time(time)
  • Tipping bucket raingauge count total(tbrg_count_total)
  • lon(lon)
  • Std Dev of Relative Humidity or Hardware Error Code(relh_sd)
  • Lower sensor, wind speed minimum(lo_spd_min)
  • Upper sensor, wind speed vector average(up_spd_vec_avg)
  • lat(lat)
  • Lower sensor, wind direction vector average(lo_dir_vec_avg)
  • Barometric Pressure(atmos_pressure)
  • Lower sensor, wind speed maximum(lo_spd_max)
  • Lower sensor, wind speed vector average(lo_spd_vec_avg)
  • Upper sensor, wind direction standard deviation(up_dir_sd)
  • Precipitation mean(precip_mean)
  • Upper sensor, wind direction vector average(up_dir_vec_avg)
  • Upper sensor, wind speed maximum(up_spd_max)
  • Upper sensor, wind speed arithmetic average(up_spd_arith_avg)
  • Tipping bucket raingauge total(tbrg_total)
  • Vapor pressure standard deviation(vappress_sd)
  • Mean Air Temperature or Hardware Error(temp_mean)
  • Mean Relative Humidity(relh_mean)
  • Std Dev of Air Temperature(temp_sd)
  • precipitation minimum(precip_min)
  • Lower sensor, wind speed arithmetic average(lo_spd_arith_avg)
  • Time offset of tweaks from base_time(time_offset)
  • Precipitation maximum(precip_max)


Back To Table of Contents

DQRID : D081022.3
Start DateStart TimeEnd DateEnd Time
10/09/1996000011/03/20080730
Subject:
TWP/SMET/C1 - Wind Speed data contain offset due to induced voltage
DataStreams:twpsmet60sC1.b1
Description:
The marine model of the RM Young wind sensor needs twisted pair shielded cable.  The 
manufacturer did not originally supply the pigtail with twisted pair shielded cable.  Use of 
twisted pair shielded cable for the rest of the cable run to the logger was also not 
specified.  This caused an induced voltage in the wind speed line from the wind direction 
excitation.  The induced voltage varied from sensor to sensor and probably changed anytime 
the cable was replaced or parts of the wind sensor were repaired or replaced. The induced 
voltage has been seen to vary from 0.15 m/s to as much as 1.08 m/s.
Measurements:twpsmet60sC1.b1:
  • Lower sensor, wind speed vector average(lo_spd_vec_avg)
  • Lower sensor, wind speed arithmetic average(lo_spd_arith_avg)
  • Upper sensor, wind speed maximum(up_spd_max)
  • Upper sensor, wind speed arithmetic average(up_spd_arith_avg)
  • Lower sensor, wind speed minimum(lo_spd_min)
  • Lower sensor, wind speed standard deviation(lo_spd_sd)
  • Upper sensor, wind speed vector average(up_spd_vec_avg)
  • Upper sensor, wind speed minimum(up_spd_min)
  • Upper sensor, wind speed standard deviation(up_spd_sd)
  • Lower sensor, wind speed maximum(lo_spd_max)


Back To Table of Contents