Data Quality Reports for Session: 122160 User: dmfoper Completed: 08/31/2009


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D070913.1FKB/MWRHF/M1 - Dew formation on windowfkbmwrhfM1.b1
D071008.1FKB/MWRHF/M1 - Reprocess: Surface Relative Humidity too lowfkbmwrhfM1.b1
D071012.3FKB/NFOV/M1 - Intermittent problem with channel 870fkbnfov2chM1.b1
D080402.2FKB/MWRHF/M1 - Questionable calibrationfkbmwrhfM1.b1


DQRID : D070913.1
Start DateStart TimeEnd DateEnd Time
06/22/2007000012/31/20072300
Subject:
FKB/MWRHF/M1 - Dew formation on window
DataStreams:fkbmwrhfM1.b1
Description:
During night time, when the humidity is very high (RH ~ 100%) data are strongly affected 
by dew formation on the window. 
This results in a smooth and large (80-150 K) increase of the brightness temperature from 
early night to sunrise. Data are affected mostly at night.
Measurements:fkbmwrhfM1.b1:
  • Sky brightness temperature (90 GHz)(tbsky90)
  • Sky brightness temperature (150 GHz)(tbsky150)


Back To Table of Contents

DQRID : D071008.1
Start DateStart TimeEnd DateEnd Time
06/22/2007190010/10/20071920
Subject:
FKB/MWRHF/M1 - Reprocess: Surface Relative Humidity too low
DataStreams:fkbmwrhfM1.b1
Description:
The surface relative humidity readings are too low when compared with the MWRP and the 
tower sensor.
Measurements:fkbmwrhfM1.b1:
  • Relative humidity inside the instrument enclosure(rh)


Back To Table of Contents

DQRID : D071012.3
Start DateStart TimeEnd DateEnd Time
04/23/2007010011/20/20070800
Subject:
FKB/NFOV/M1 - Intermittent problem with channel 870
DataStreams:fkbnfov2chM1.b1
Description:
At times channel 870 is erratic.  Fortunately, it is mostly at night when it is not 
functioning properly.  The erratic behavior is infrequent until Sept when it becomes a bit more 
frequent.  Even then, however, very little daytime data are affected.
Measurements:fkbnfov2chM1.b1:
  • Calibrated Zenith Radiance, 870 nm(radiance_870nm)
  • Raw counts from instrument before calibration, 870 nm(raw_counts_870nm)


Back To Table of Contents

DQRID : D080402.2
Start DateStart TimeEnd DateEnd Time
07/01/2007000010/13/20071615
Subject:
FKB/MWRHF/M1 - Questionable calibration
DataStreams:fkbmwrhfM1.b1
Description:
The instrument completed a tip curve calibration on June 30 and it did not calibrate again 
until Oct 13. Data during this time display large residuals (~ 6 K) when compared with 
model computations. It is likely that the tip curve calibration, although successful, 
wasn't good enough to have good accuracy.

Since this instrument is still under testing the users should use the data with caution. 
Although the accuracy of the model itself is still debated, large residuals between the 
measurements and the model between June and October are probably in large part due to the 
poor calibration.
Measurements:fkbmwrhfM1.b1:
  • Sky brightness temperature (90 GHz)(tbsky90)
  • Sky brightness temperature (150 GHz)(tbsky150)


Back To Table of Contents



END OF DATA