Data Quality Reports for Session: 120243 User: jcomstock Completed: 06/12/2009


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D070306.2TWP/SMET/C3 - Barometer Data Incorrecttwpsmet60sC3.b1
D070306.3TWP/SMET/C3 - Water in enclosuretwpsmet60sC3.b1
D070803.1TWP/SMET/C3 - Upper wind speed artificially slowtwpsmet60sC3.b1
D071105.1TWP/SMET/C3 - ORG overestimated rainfalltwpsmet60sC3.b1
D081022.8TWP/SMET/C3 - Wind Speed data contain offset due to induced voltagetwpsmet60sC3.b1
D090515.1TWP/SMET/C3 - Reprocess: Temperature Biased low by 1.06 Degreestwpsmet60sC3.b1


DQRID : D070306.2
Start DateStart TimeEnd DateEnd Time
03/02/2007172303/03/20071228
Subject:
TWP/SMET/C3 - Barometer Data Incorrect
DataStreams:twpsmet60sC3.b1
Description:
The barometer data was incorrect or missing due to water intrusion.
Measurements:twpsmet60sC3.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D070306.3
Start DateStart TimeEnd DateEnd Time
03/03/2007005603/03/20070123
Subject:
TWP/SMET/C3 - Water in enclosure
DataStreams:twpsmet60sC3.b1
Description:
Data became erratic and unreasonable after water intrusion into the enclosure.
Measurements:twpsmet60sC3.b1:
  • Precipitation mean(precip_mean)
  • Vapor pressure standard deviation(vappress_sd)
  • Precipitation maximum(precip_max)
  • Mean Relative Humidity(relh_mean)
  • Mean Air Temperature or Hardware Error(temp_mean)
  • Precipitation standard deviation(precip_sd)
  • Vapor pressure mean(vappress_mean)
  • Std Dev of Relative Humidity or Hardware Error Code(relh_sd)
  • precipitation minimum(precip_min)
  • Std Dev of Air Temperature(temp_sd)


Back To Table of Contents

DQRID : D070803.1
Start DateStart TimeEnd DateEnd Time
07/01/2007000009/18/20072315
Subject:
TWP/SMET/C3 - Upper wind speed artificially slow
DataStreams:twpsmet60sC3.b1
Description:
The upper wind measurement was consistently slower by around 0.5 - 1 m/s than the lower 
wind measurement.  The bearings on the upper wind measurement were binding.
Measurements:twpsmet60sC3.b1:
  • Upper sensor, wind speed maximum(up_spd_max)
  • Upper sensor, wind speed arithmetic average(up_spd_arith_avg)
  • Upper sensor, wind speed minimum(up_spd_min)
  • Upper sensor, wind speed vector average(up_spd_vec_avg)
  • Upper sensor, wind speed standard deviation(up_spd_sd)


Back To Table of Contents

DQRID : D071105.1
Start DateStart TimeEnd DateEnd Time
11/02/2007185511/02/20072010
Subject:
TWP/SMET/C3 - ORG overestimated rainfall
DataStreams:twpsmet60sC3.b1
Description:
Optical rain gauge (ORG) measured approximately 10mm higher than two co-located tipping 
bucket rain gauges and a co-located disdrometer.  The ORG is typically higher but usually 
not by an order of magnitude.
Measurements:twpsmet60sC3.b1:
  • Precipitation mean(precip_mean)
  • Precipitation maximum(precip_max)
  • Precipitation standard deviation(precip_sd)
  • precipitation minimum(precip_min)


Back To Table of Contents

DQRID : D081022.8
Start DateStart TimeEnd DateEnd Time
03/12/2002000010/17/20080627
Subject:
TWP/SMET/C3 - Wind Speed data contain offset due to induced voltage
DataStreams:twpsmet60sC3.b1
Description:
The marine model of the RM Young wind sensor needs twisted pair shielded cable.  The 
manufacturer did not originally supply the pigtail with twisted pair shielded cable.  Use of 
twisted pair shielded cable for the rest of the cable run to the logger was also not 
specified.  This caused an induced voltage in the wind speed line from the wind direction 
excitation.  The induced voltage varied from sensor to sensor and probably changed anytime 
the cable was replaced or parts of the wind sensor were repaired or replaced. The induced 
voltage has been seen to vary from 0.15 m/s to as much as 1.08 m/s.
Measurements:twpsmet60sC3.b1:
  • Upper sensor, wind speed maximum(up_spd_max)
  • Lower sensor, wind speed minimum(lo_spd_min)
  • Lower sensor, wind speed standard deviation(lo_spd_sd)
  • Lower sensor, wind speed maximum(lo_spd_max)
  • Upper sensor, wind speed arithmetic average(up_spd_arith_avg)
  • Lower sensor, wind speed vector average(lo_spd_vec_avg)
  • Upper sensor, wind speed minimum(up_spd_min)
  • Lower sensor, wind speed arithmetic average(lo_spd_arith_avg)
  • Upper sensor, wind speed vector average(up_spd_vec_avg)
  • Upper sensor, wind speed standard deviation(up_spd_sd)


Back To Table of Contents

DQRID : D090515.1
Start DateStart TimeEnd DateEnd Time
04/19/2005042004/04/20090115
Subject:
TWP/SMET/C3 - Reprocess: Temperature Biased low by 1.06 Degrees
DataStreams:twpsmet60sC3.b1
Description:
The temperature of the SMET system was biased low by 1.06 Deg C due to a non-precision 
resistor being used int he measurement circuit.  The data will be reprocessed.  Saturation 
Vapor pressure and Vapor pressure will have to be reprocessed also.

Add 1.06 degrees to the temperature data.  

Correct Sat Vap Press using the Buck approximation:
   Es = 6.1121exp((17.502*T)/(240.97 + T) 
where T is the temperature in C.  

Correct Vapor pressure using: E = (RH*Es)/100
Measurements:twpsmet60sC3.b1:
  • Vapor pressure standard deviation(vappress_sd)
  • Mean Air Temperature or Hardware Error(temp_mean)
  • Vapor pressure mean(vappress_mean)
  • Std Dev of Air Temperature(temp_sd)


Back To Table of Contents



END OF DATA