Data Quality Reports for Session: 119821 User: dmfoper Completed: 05/28/2009


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D011221.6SGP/EBBR/E9 - Reprocess: E9 EBBR Soil Temperature #5 Intermittently Incorrectsgp15ebbrE9.a1, sgp15ebbrE9.b1, sgp30ebbrE9.a1, sgp30ebbrE9.b1
D020716.10SGP/EBBR/E9 - 6 Month Checkssgp15ebbrE9.a1, sgp15ebbrE9.b1, sgp30ebbrE9.a1, sgp30ebbrE9.b1, sgp5ebbrE9.a1
D020717.3SGP/EBBR/E9 - Measurements All Zerossgp15ebbrE9.a1, sgp15ebbrE9.b1, sgp30ebbrE9.a1, sgp30ebbrE9.b1, sgp5ebbrE9.00,
sgp5ebbrE9.a1
D030114.8SGP/EBBR/E9 - Net Rad data bad during dome replacementsgp15ebbrE9.a1, sgp15ebbrE9.b1, sgp30ebbrE9.a1, sgp30ebbrE9.b1, sgp5ebbrE9.a1
D030114.9SGP/EBBR/E9 - AEM Malfunctionsgp15ebbrE9.a1, sgp15ebbrE9.b1, sgp30ebbrE9.a1, sgp30ebbrE9.b1, sgp5ebbrE9.a1
D030712.1SGP/EBBR/E9 - AEM Hung Inbetween Home Positionssgp15ebbrE9.a1, sgp15ebbrE9.b1, sgp30ebbrE9.a1, sgp30ebbrE9.b1, sgp5ebbrE9.a1
D030712.15SGP/EBBR/E9 - 6 Month Checkssgp15ebbrE9.a1, sgp15ebbrE9.b1, sgp30ebbrE9.a1, sgp30ebbrE9.b1, sgp5ebbrE9.a1
D030712.2SGP/EBBR/E9 - Soil Heat Flow #1 Incorrectsgp15ebbrE9.a1, sgp15ebbrE9.b1, sgp30ebbrE9.a1, sgp30ebbrE9.b1
D030712.3SGP/EBBR/E9 - Battery Voltage Lowsgp15ebbrE9.a1, sgp15ebbrE9.b1, sgp30ebbrE9.a1, sgp30ebbrE9.b1, sgp5ebbrE9.a1
D030729.2SGP/EBBR/E9 - AEM Hung in home 30 position.sgp15ebbrE9.a1, sgp15ebbrE9.b1, sgp30ebbrE9.a1, sgp30ebbrE9.b1, sgp5ebbrE9.a1
D030919.7SGP/EBBR/E9 - Water in Net Radiometer; Surface Fluxes are Incorrectsgp15ebbrE9.a1, sgp15ebbrE9.b1, sgp30ebbrE9.a1, sgp30ebbrE9.b1, sgp5ebbrE9.a1
D031031.3SGP/EBBR/E9 - Measurements All Zerosgp15ebbrE9.a1, sgp15ebbrE9.b1, sgp30ebbrE9.a1, sgp30ebbrE9.b1, sgp5ebbrE9.a1
D031204.8SGP/EBBR/E9 - 6 Month Checkssgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
D031222.13SGP/EBBR/E9 - Net Radiometer Iced Over During Stormsgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
D031222.14SGP/EBBR/E9 - Wind Speed Sensor Frozen By Ice Stormsgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
D040304.8SGP/EBBR/E9 - Wind Speed Frozen Stopped By Icesgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
D051112.6SGP/EBBR/E9 - metadata correctionssgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1


DQRID : D011221.6
Start DateStart TimeEnd DateEnd Time
05/15/2001231512/14/20012356
Subject:
SGP/EBBR/E9 - Reprocess: E9 EBBR Soil Temperature #5 Intermittently Incorrect
DataStreams:sgp15ebbrE9.a1, sgp15ebbrE9.b1, sgp30ebbrE9.a1, sgp30ebbrE9.b1
Description:
Soil moisture probe #5 in the recalibrated unit installed
on 5/11/01 has not been working all of the time.  At times
the measurement has been very large and incorrect.  The
indicated measurements are incorrect at those times.  The
data must be inspected to determine the times that 
have incorrect data.  The sensible and latent heat fluxes can
be recalculated by using soil sets 1, 2, 3, and 4 only in a 
recalculation of the energy budget.
Measurements:sgp15ebbrE9.b1:
  • soil_temp_5_rr

sgp30ebbrE9.b1:
  • soil_temp_5
  • latent_heat_flux
  • energy_storage_change_5
  • sensible_heat_flux
  • surface_soil_heat_flux_avg
  • surface_soil_heat_flux_5

sgp15ebbrE9.a1:
  • Soil temperature 5(rr_ts5)

sgp30ebbrE9.a1:
  • 0-5 cm integrated soil temperature, site 5(ts5)
  • 0-5 cm change in soil heat storage with time, site 5(ces5)
  • average surface soil heat flow(ave_shf)
  • latent heat flux(e)
  • h(h)
  • soil heat flow, site 5(g5)


Back To Table of Contents

DQRID : D020716.10
Start DateStart TimeEnd DateEnd Time
05/09/2002160005/09/20021631
Subject:
SGP/EBBR/E9 - 6 Month Checks
DataStreams:sgp15ebbrE9.a1, sgp15ebbrE9.b1, sgp30ebbrE9.a1, sgp30ebbrE9.b1, sgp5ebbrE9.a1
Description:
The indicated measurements were incorrect during the 6 month checks.
Measurements:sgp15ebbrE9.b1:
  • temp_air_left
  • temp_air_right

sgp30ebbrE9.b1:
  • latent_heat_flux
  • bowen_ratio
  • temp_air_bottom
  • vapor_pressure_bottom
  • temp_trh_top
  • temp_trh_bottom
  • rh_top_fraction
  • temp_air_top
  • sensible_heat_flux
  • vapor_pressure_top
  • rh_bottom_fraction

sgp5ebbrE9.a1:
  • top vapor pressure(vp_top)
  • top air temperature(tair_top)
  • Top humidity(hum_top)
  • bottom air temperature(tair_bot)
  • Bottom humidity(hum_bot)
  • bottom vapor pressure(vp_bot)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • Temperature of the top humidity chamber(thum_top)

sgp15ebbrE9.a1:
  • Left air temperature(tair_l)
  • Right air temperature(tair_r)

sgp30ebbrE9.a1:
  • latent heat flux(e)
  • top air temperature(tair_top)
  • Temperature of the top humidity chamber(thum_top)
  • Bottom humidity(hum_bot)
  • Top humidity(hum_top)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • bottom air temperature(tair_bot)
  • bottom vapor pressure(vp_bot)
  • h(h)
  • top vapor pressure(vp_top)
  • ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)


Back To Table of Contents

DQRID : D020717.3
Start DateStart TimeEnd DateEnd Time
03/28/2002160003/28/20021601
06/04/2002150006/04/20021501
Subject:
SGP/EBBR/E9 - Measurements All Zeros
DataStreams:sgp15ebbrE9.a1, sgp15ebbrE9.b1, sgp30ebbrE9.a1, sgp30ebbrE9.b1, sgp5ebbrE9.00,
sgp5ebbrE9.a1
Description:
The measurements were all zeros at the indicated times.  This occurs after a CR10 program 
restart, which sometimes happens after some servicing of the EBBR is performed.
Measurements:sgp15ebbrE9.b1:
  • soil_heat_flow_4_mv
  • soil_moisture_1_rr
  • soil_moisture_4_rr
  • soil_temp_4_rr
  • soil_moisture_2_rr
  • soil_heat_flow_5_mv
  • temp_trh_left_rr
  • net_radiation_mv
  • soil_moisture_5_rr
  • soil_heat_flow_3_mv
  • battery_voltage
  • temp_air_right
  • soil_temp_2_rr
  • soil_heat_flow_2_mv
  • rh_right_mv
  • wspd_arith_mean
  • temp_trh_right_rr
  • soil_moisture_3_rr
  • soil_temp_3_rr
  • wdir_vec_mean_mv
  • atmos_pressure_mv
  • soil_temp_5_rr
  • soil_temp_1_rr
  • temp_air_left
  • soil_heat_flow_1_mv
  • home_signal
  • temp_reference_rr
  • rh_left_mv

sgp30ebbrE9.b1:
  • soil_moisture_2
  • soil_temp_2
  • soil_temp_5
  • bowen_ratio
  • temp_trh_top
  • corr_soil_heat_flow_1
  • soil_heat_flow_1
  • temp_reference
  • vapor_pressure_top
  • wdir_vec_mean
  • soil_moisture_4
  • soil_moisture_3
  • Barometric Pressure(atmos_pressure)
  • soil_heat_capacity_1
  • corr_soil_heat_flow_4
  • energy_storage_change_5
  • energy_storage_change_4
  • soil_heat_flow_5
  • wdir_vec_std
  • temp_trh_bottom
  • energy_storage_change_2
  • temp_air_top
  • net_radiation
  • sensible_heat_flux
  • soil_heat_capacity_4
  • surface_soil_heat_flux_avg
  • soil_heat_flow_4
  • surface_soil_heat_flux_5
  • soil_heat_capacity_2
  • corr_soil_heat_flow_5
  • soil_moisture_5
  • soil_heat_flow_2
  • home_signal_30
  • energy_storage_change_3
  • soil_heat_capacity_3
  • home_signal_15
  • surface_soil_heat_flux_1
  • rh_top_fraction
  • surface_soil_heat_flux_2
  • soil_heat_capacity_5
  • surface_soil_heat_flux_4
  • soil_heat_flow_3
  • corr_soil_heat_flow_3
  • latent_heat_flux
  • temp_air_bottom
  • soil_temp_3
  • vapor_pressure_bottom
  • corr_soil_heat_flow_2
  • wspd_arith_mean
  • surface_soil_heat_flux_3
  • soil_moisture_1
  • rh_bottom_fraction
  • wspd_vec_mean
  • soil_temp_4
  • soil_temp_1
  • energy_storage_change_1

sgp5ebbrE9.00:
  • null(Raw data stream - documentation not supported)

sgp5ebbrE9.a1:
  • vector wind speed(res_ws)
  • Home signal(home)
  • Top humidity(hum_top)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • standard deviation of wind direction (sigma theta)(sigma_wd)
  • bottom air temperature(tair_bot)
  • wind direction (relative to true north)(wind_d)
  • top vapor pressure(vp_top)
  • top air temperature(tair_top)
  • bottom vapor pressure(vp_bot)
  • Retrieved pressure profile(pres)
  • Reference Thermistor Temperature(tref)
  • Bottom humidity(hum_bot)
  • scalar wind speed(wind_s)
  • net radiation(q)
  • Temperature of the top humidity chamber(thum_top)

sgp15ebbrE9.a1:
  • Left air temperature(tair_l)
  • Soil moisture 3(r_sm3)
  • Temperature of right humidity sensor chamber(rr_thum_r)
  • Soil moisture 2(r_sm2)
  • Soil moisture 1(rr_sm1)
  • Soil moisture 4(rr_sm4)
  • Soil moisture 2(rr_sm2)
  • Soil moisture 3(rr_sm3)
  • Soil moisture 5(rr_sm5)
  • Reference temperature(rr_tref)
  • Soil moisture 4(r_sm4)
  • Soil temperature 5(rr_ts5)
  • Wind direction (relative to true north)(mv_wind_d)
  • Soil temperature 4(rr_ts4)
  • Left relative humidity(mv_hum_l)
  • Soil heat flow 4(mv_hft4)
  • Soil moisture 5(r_sm5)
  • Battery(bat)
  • Soil temperature 2(rr_ts2)
  • Home signal(mv_home)
  • Temperature of left humidity sensor chamber(rr_thum_l)
  • Right air temperature(tair_r)
  • Soil temperature 3(rr_ts3)
  • Right relative humidity(mv_hum_r)
  • Soil temperature 1(rr_ts1)
  • Soil heat flow 1(mv_hft1)
  • scalar wind speed(wind_s)
  • Soil heat flow 5(mv_hft5)
  • Atmospheric pressure(mv_pres)
  • Soil heat flow 3(mv_hft3)
  • Net radiation(mv_q)
  • Soil moisture 1(r_sm1)
  • Soil heat flow 2(mv_hft2)

sgp30ebbrE9.a1:
  • 0-5 cm change in soil heat storage with time, site 2(ces2)
  • soil heat flow, site 4(g4)
  • soil heat flow, site 1(g1)
  • 0-5 cm change in soil heat storage with time, site 2(ces1)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • h(h)
  • 5 cm soil heat flow, site 1(shf1)
  • soil heat flow, site 5(g5)
  • 0-5 cm integrated soil temperature, site 2(ts1)
  • soil heat flow, site 2(g2)
  • latent heat flux(e)
  • 0-5 cm change in soil heat storage with time, site 4(ces4)
  • 0-5 cm integrated soil temperature, site 5(ts5)
  • 0-5 cm change in soil heat storage with time, site 5(ces5)
  • wind direction (relative to true north)(wind_d)
  • Soil heat capacity 3(cs3)
  • Exchange mechanism position indicator (0 to 15 min)(home_15)
  • 5 cm soil heat flow, site 4(shf4)
  • 0-5 cm integrated soil temperature, site 3(ts3)
  • Soil heat capacity 2(cs2)
  • top vapor pressure(vp_top)
  • Soil heat capacity 1(cs1)
  • 0-5 cm change in soil heat storage with time, site 3(ces3)
  • soil heat flow, site 3(g3)
  • net radiation(q)
  • 5 cm soil heat flow corrected for soil moisture content, site 3(c_shf3)
  • Reference Thermistor Temperature(tref)
  • standard deviation of wind direction (sigma theta)(sigma_wd)
  • Soil heat capacity 4(cs4)
  • 5 cm soil heat flow corrected for soil moisture content, site 4(c_shf4)
  • volumetric soil moisture, site 3(sm3)
  • average surface soil heat flow(ave_shf)
  • volumetric soil moisture, site 4(sm4)
  • 5 cm soil heat flow corrected for soil moisture content, site 5(c_shf5)
  • 5 cm soil heat flow, site 5(shf5)
  • Bottom humidity(hum_bot)
  • 0-5 cm integrated soil temperature, site 2(ts2)
  • Soil heat capacity 5(cs5)
  • scalar wind speed(wind_s)
  • 5 cm soil heat flow, site 2(shf2)
  • 5 cm soil heat flow corrected for soil moisture content, site 2(c_shf2)
  • 5 cm soil heat flow, site 3(shf3)
  • bottom air temperature(tair_bot)
  • 0-5 cm integrated soil temperature, site 4(ts4)
  • bottom vapor pressure(vp_bot)
  • Retrieved pressure profile(pres)
  • volumetric soil moisture, site 5(sm5)
  • Exchange mechanism position indicator (15 to 30 min)(home_30)
  • vector wind speed(res_ws)
  • top air temperature(tair_top)
  • Temperature of the top humidity chamber(thum_top)
  • Top humidity(hum_top)
  • volumetric soil moisture, site 1(sm1)
  • 5 cm soil heat flow corrected for soil moisture content, site 1(c_shf1)
  • ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)
  • volumetric soil moisture, site 2(sm2)


Back To Table of Contents

DQRID : D030114.8
Start DateStart TimeEnd DateEnd Time
09/24/2002160009/24/20021630
Subject:
SGP/EBBR/E9 - Net Rad data bad during dome replacement
DataStreams:sgp15ebbrE9.a1, sgp15ebbrE9.b1, sgp30ebbrE9.a1, sgp30ebbrE9.b1, sgp5ebbrE9.a1
Description:
The net radiation measurement was incorrect during replacement
of the top dome. Measurements calculated using net radiation are also incorrect.
Measurements:sgp15ebbrE9.b1:
  • net_radiation_mv

sgp30ebbrE9.b1:
  • latent_heat_flux
  • net_radiation
  • sensible_heat_flux

sgp5ebbrE9.a1:
  • net radiation(q)

sgp15ebbrE9.a1:
  • Net radiation(mv_q)

sgp30ebbrE9.a1:
  • net radiation(q)
  • h(h)
  • latent heat flux(e)


Back To Table of Contents

DQRID : D030114.9
Start DateStart TimeEnd DateEnd Time
11/16/2002133011/16/20021430
11/17/2002070011/19/20021730
Subject:
SGP/EBBR/E9 - AEM Malfunction
DataStreams:sgp15ebbrE9.a1, sgp15ebbrE9.b1, sgp30ebbrE9.a1, sgp30ebbrE9.b1, sgp5ebbrE9.a1
Description:
When the AEM (Automatic Exchange Mechanism) is hung 
inbetween a home position, the gradients of temperature and 
relative humidity, and thus sensible and latent heat fluxes, 
are incorrect.
Measurements:sgp15ebbrE9.b1:
  • temp_air_left
  • temp_air_right

sgp30ebbrE9.b1:
  • latent_heat_flux
  • bowen_ratio
  • temp_air_bottom
  • vapor_pressure_bottom
  • temp_trh_top
  • temp_trh_bottom
  • rh_top_fraction
  • temp_air_top
  • sensible_heat_flux
  • vapor_pressure_top
  • rh_bottom_fraction

sgp5ebbrE9.a1:
  • top vapor pressure(vp_top)
  • top air temperature(tair_top)
  • Top humidity(hum_top)
  • bottom air temperature(tair_bot)
  • Bottom humidity(hum_bot)
  • bottom vapor pressure(vp_bot)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • Temperature of the top humidity chamber(thum_top)

sgp15ebbrE9.a1:
  • Left air temperature(tair_l)
  • Right air temperature(tair_r)

sgp30ebbrE9.a1:
  • latent heat flux(e)
  • top air temperature(tair_top)
  • Temperature of the top humidity chamber(thum_top)
  • Bottom humidity(hum_bot)
  • Top humidity(hum_top)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • bottom air temperature(tair_bot)
  • bottom vapor pressure(vp_bot)
  • h(h)
  • top vapor pressure(vp_top)
  • ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)


Back To Table of Contents

DQRID : D030712.1
Start DateStart TimeEnd DateEnd Time
02/23/2003200003/13/20031745
Subject:
SGP/EBBR/E9  - AEM Hung Inbetween Home Positions
DataStreams:sgp15ebbrE9.a1, sgp15ebbrE9.b1, sgp30ebbrE9.a1, sgp30ebbrE9.b1, sgp5ebbrE9.a1
Description:
The AEM was hung inbetween home positions, causing many measurements to be incorrect.
Measurements:sgp15ebbrE9.b1:
  • rh_right_mv
  • temp_air_left
  • temp_trh_left_rr
  • temp_trh_right_rr
  • temp_air_right
  • rh_left_mv

sgp30ebbrE9.b1:
  • latent_heat_flux
  • bowen_ratio
  • temp_air_bottom
  • vapor_pressure_bottom
  • temp_trh_top
  • temp_trh_bottom
  • rh_top_fraction
  • temp_air_top
  • sensible_heat_flux
  • vapor_pressure_top
  • rh_bottom_fraction

sgp5ebbrE9.a1:
  • top vapor pressure(vp_top)
  • top air temperature(tair_top)
  • Top humidity(hum_top)
  • bottom air temperature(tair_bot)
  • Bottom humidity(hum_bot)
  • bottom vapor pressure(vp_bot)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • Temperature of the top humidity chamber(thum_top)

sgp15ebbrE9.a1:
  • Left air temperature(tair_l)
  • Temperature of right humidity sensor chamber(rr_thum_r)
  • Right relative humidity(mv_hum_r)
  • Temperature of left humidity sensor chamber(rr_thum_l)
  • Right air temperature(tair_r)
  • Left relative humidity(mv_hum_l)

sgp30ebbrE9.a1:
  • latent heat flux(e)
  • top air temperature(tair_top)
  • Temperature of the top humidity chamber(thum_top)
  • Bottom humidity(hum_bot)
  • Top humidity(hum_top)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • bottom air temperature(tair_bot)
  • bottom vapor pressure(vp_bot)
  • h(h)
  • top vapor pressure(vp_top)
  • ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)


Back To Table of Contents

DQRID : D030712.15
Start DateStart TimeEnd DateEnd Time
04/24/2003180004/24/20031830
Subject:
SGP/EBBR/E9  - 6 Month Checks
DataStreams:sgp15ebbrE9.a1, sgp15ebbrE9.b1, sgp30ebbrE9.a1, sgp30ebbrE9.b1, sgp5ebbrE9.a1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp15ebbrE9.b1:
  • rh_right_mv
  • temp_air_left
  • temp_trh_left_rr
  • temp_trh_right_rr
  • temp_air_right
  • rh_left_mv

sgp30ebbrE9.b1:
  • latent_heat_flux
  • bowen_ratio
  • temp_air_bottom
  • vapor_pressure_bottom
  • temp_trh_top
  • temp_trh_bottom
  • rh_top_fraction
  • temp_air_top
  • sensible_heat_flux
  • vapor_pressure_top
  • rh_bottom_fraction

sgp5ebbrE9.a1:
  • top vapor pressure(vp_top)
  • top air temperature(tair_top)
  • Top humidity(hum_top)
  • bottom air temperature(tair_bot)
  • Bottom humidity(hum_bot)
  • bottom vapor pressure(vp_bot)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • Temperature of the top humidity chamber(thum_top)

sgp15ebbrE9.a1:
  • Left air temperature(tair_l)
  • Temperature of right humidity sensor chamber(rr_thum_r)
  • Right relative humidity(mv_hum_r)
  • Temperature of left humidity sensor chamber(rr_thum_l)
  • Right air temperature(tair_r)
  • Left relative humidity(mv_hum_l)

sgp30ebbrE9.a1:
  • latent heat flux(e)
  • top air temperature(tair_top)
  • Temperature of the top humidity chamber(thum_top)
  • Bottom humidity(hum_bot)
  • Top humidity(hum_top)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • bottom air temperature(tair_bot)
  • bottom vapor pressure(vp_bot)
  • h(h)
  • top vapor pressure(vp_top)
  • ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)


Back To Table of Contents

DQRID : D030712.2
Start DateStart TimeEnd DateEnd Time
05/09/2003180005/09/20031800
Subject:
SGP/EBBR/E9  - Soil Heat Flow #1 Incorrect
DataStreams:sgp15ebbrE9.a1, sgp15ebbrE9.b1, sgp30ebbrE9.a1, sgp30ebbrE9.b1
Description:
Soil Heat Flow #1 was incorrect.
Measurements:sgp15ebbrE9.b1:
  • soil_heat_flow_1_mv

sgp30ebbrE9.b1:
  • soil_heat_flow_1
  • latent_heat_flux
  • sensible_heat_flux
  • surface_soil_heat_flux_avg
  • surface_soil_heat_flux_1
  • corr_soil_heat_flow_1

sgp15ebbrE9.a1:
  • Soil heat flow 1(mv_hft1)

sgp30ebbrE9.a1:
  • 5 cm soil heat flow corrected for soil moisture content, site 1(c_shf1)
  • soil heat flow, site 1(g1)
  • average surface soil heat flow(ave_shf)
  • latent heat flux(e)
  • h(h)
  • 5 cm soil heat flow, site 1(shf1)


Back To Table of Contents

DQRID : D030712.3
Start DateStart TimeEnd DateEnd Time
05/14/2003110005/30/20031700
Subject:
SGP/EBBR/E9 -   Battery Voltage Low
DataStreams:sgp15ebbrE9.a1, sgp15ebbrE9.b1, sgp30ebbrE9.a1, sgp30ebbrE9.b1, sgp5ebbrE9.a1
Description:
Many of the measurements are incorrect much of the time during this period,
when the battery voltage was 10.9 volts or less.
Measurements:sgp15ebbrE9.b1:
  • soil_heat_flow_4_mv
  • soil_moisture_1_rr
  • soil_moisture_4_rr
  • soil_temp_4_rr
  • soil_moisture_2_rr
  • soil_heat_flow_5_mv
  • temp_trh_left_rr
  • net_radiation_mv
  • soil_moisture_5_rr
  • soil_heat_flow_3_mv
  • temp_air_right
  • soil_temp_2_rr
  • soil_heat_flow_2_mv
  • rh_right_mv
  • wspd_arith_mean
  • temp_trh_right_rr
  • soil_moisture_3_rr
  • soil_temp_3_rr
  • wdir_vec_mean_mv
  • atmos_pressure_mv
  • soil_temp_5_rr
  • soil_temp_1_rr
  • temp_air_left
  • soil_heat_flow_1_mv
  • home_signal
  • temp_reference_rr
  • rh_left_mv

sgp30ebbrE9.b1:
  • soil_moisture_2
  • soil_temp_2
  • soil_temp_5
  • bowen_ratio
  • temp_trh_top
  • corr_soil_heat_flow_1
  • soil_heat_flow_1
  • temp_reference
  • vapor_pressure_top
  • wdir_vec_mean
  • soil_moisture_4
  • soil_moisture_3
  • Barometric Pressure(atmos_pressure)
  • soil_heat_capacity_1
  • corr_soil_heat_flow_4
  • energy_storage_change_5
  • energy_storage_change_4
  • soil_heat_flow_5
  • wdir_vec_std
  • temp_trh_bottom
  • energy_storage_change_2
  • temp_air_top
  • net_radiation
  • sensible_heat_flux
  • soil_heat_capacity_4
  • surface_soil_heat_flux_avg
  • soil_heat_flow_4
  • surface_soil_heat_flux_5
  • soil_heat_capacity_2
  • corr_soil_heat_flow_5
  • soil_moisture_5
  • soil_heat_flow_2
  • home_signal_30
  • energy_storage_change_3
  • soil_heat_capacity_3
  • home_signal_15
  • surface_soil_heat_flux_1
  • rh_top_fraction
  • surface_soil_heat_flux_2
  • soil_heat_capacity_5
  • surface_soil_heat_flux_4
  • soil_heat_flow_3
  • corr_soil_heat_flow_3
  • latent_heat_flux
  • temp_air_bottom
  • soil_temp_3
  • vapor_pressure_bottom
  • corr_soil_heat_flow_2
  • wspd_arith_mean
  • surface_soil_heat_flux_3
  • soil_moisture_1
  • rh_bottom_fraction
  • wspd_vec_mean
  • soil_temp_4
  • soil_temp_1
  • energy_storage_change_1

sgp5ebbrE9.a1:
  • vector wind speed(res_ws)
  • Home signal(home)
  • Top humidity(hum_top)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • standard deviation of wind direction (sigma theta)(sigma_wd)
  • bottom air temperature(tair_bot)
  • wind direction (relative to true north)(wind_d)
  • top vapor pressure(vp_top)
  • top air temperature(tair_top)
  • bottom vapor pressure(vp_bot)
  • Retrieved pressure profile(pres)
  • Reference Thermistor Temperature(tref)
  • Bottom humidity(hum_bot)
  • scalar wind speed(wind_s)
  • net radiation(q)
  • Temperature of the top humidity chamber(thum_top)

sgp15ebbrE9.a1:
  • Left air temperature(tair_l)
  • Soil moisture 3(r_sm3)
  • Temperature of right humidity sensor chamber(rr_thum_r)
  • Soil moisture 2(r_sm2)
  • Soil moisture 1(rr_sm1)
  • Soil moisture 4(rr_sm4)
  • Soil moisture 2(rr_sm2)
  • Soil moisture 3(rr_sm3)
  • Soil moisture 5(rr_sm5)
  • Reference temperature(rr_tref)
  • Soil moisture 4(r_sm4)
  • Soil temperature 5(rr_ts5)
  • Wind direction (relative to true north)(mv_wind_d)
  • Soil temperature 4(rr_ts4)
  • Left relative humidity(mv_hum_l)
  • Soil heat flow 4(mv_hft4)
  • Soil moisture 5(r_sm5)
  • Soil temperature 2(rr_ts2)
  • Home signal(mv_home)
  • Temperature of left humidity sensor chamber(rr_thum_l)
  • Right air temperature(tair_r)
  • Soil temperature 3(rr_ts3)
  • Right relative humidity(mv_hum_r)
  • Soil temperature 1(rr_ts1)
  • Soil heat flow 1(mv_hft1)
  • scalar wind speed(wind_s)
  • Soil heat flow 5(mv_hft5)
  • Atmospheric pressure(mv_pres)
  • Soil heat flow 3(mv_hft3)
  • Net radiation(mv_q)
  • Soil moisture 1(r_sm1)
  • Soil heat flow 2(mv_hft2)

sgp30ebbrE9.a1:
  • 0-5 cm change in soil heat storage with time, site 2(ces2)
  • soil heat flow, site 4(g4)
  • soil heat flow, site 1(g1)
  • 0-5 cm change in soil heat storage with time, site 2(ces1)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • h(h)
  • 5 cm soil heat flow, site 1(shf1)
  • soil heat flow, site 5(g5)
  • 0-5 cm integrated soil temperature, site 2(ts1)
  • soil heat flow, site 2(g2)
  • latent heat flux(e)
  • 0-5 cm change in soil heat storage with time, site 4(ces4)
  • 0-5 cm integrated soil temperature, site 5(ts5)
  • 0-5 cm change in soil heat storage with time, site 5(ces5)
  • wind direction (relative to true north)(wind_d)
  • Soil heat capacity 3(cs3)
  • Exchange mechanism position indicator (0 to 15 min)(home_15)
  • 5 cm soil heat flow, site 4(shf4)
  • Soil heat capacity 2(cs2)
  • 0-5 cm integrated soil temperature, site 3(ts3)
  • top vapor pressure(vp_top)
  • Soil heat capacity 1(cs1)
  • 0-5 cm change in soil heat storage with time, site 3(ces3)
  • soil heat flow, site 3(g3)
  • net radiation(q)
  • 5 cm soil heat flow corrected for soil moisture content, site 3(c_shf3)
  • Reference Thermistor Temperature(tref)
  • Soil heat capacity 4(cs4)
  • standard deviation of wind direction (sigma theta)(sigma_wd)
  • 5 cm soil heat flow corrected for soil moisture content, site 4(c_shf4)
  • volumetric soil moisture, site 3(sm3)
  • average surface soil heat flow(ave_shf)
  • volumetric soil moisture, site 4(sm4)
  • 5 cm soil heat flow corrected for soil moisture content, site 5(c_shf5)
  • 5 cm soil heat flow, site 5(shf5)
  • Bottom humidity(hum_bot)
  • 0-5 cm integrated soil temperature, site 2(ts2)
  • Soil heat capacity 5(cs5)
  • scalar wind speed(wind_s)
  • 5 cm soil heat flow, site 2(shf2)
  • 5 cm soil heat flow corrected for soil moisture content, site 2(c_shf2)
  • 5 cm soil heat flow, site 3(shf3)
  • bottom air temperature(tair_bot)
  • 0-5 cm integrated soil temperature, site 4(ts4)
  • bottom vapor pressure(vp_bot)
  • Retrieved pressure profile(pres)
  • volumetric soil moisture, site 5(sm5)
  • Exchange mechanism position indicator (15 to 30 min)(home_30)
  • vector wind speed(res_ws)
  • top air temperature(tair_top)
  • Temperature of the top humidity chamber(thum_top)
  • Top humidity(hum_top)
  • volumetric soil moisture, site 1(sm1)
  • 5 cm soil heat flow corrected for soil moisture content, site 1(c_shf1)
  • ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)
  • volumetric soil moisture, site 2(sm2)


Back To Table of Contents

DQRID : D030729.2
Start DateStart TimeEnd DateEnd Time
07/24/2003123008/12/20031615
Subject:
SGP/EBBR/E9 - AEM Hung in home 30 position.
DataStreams:sgp15ebbrE9.a1, sgp15ebbrE9.b1, sgp30ebbrE9.a1, sgp30ebbrE9.b1, sgp5ebbrE9.a1
Description:
The AEM was hung in the home 30 position.
Measurements:sgp15ebbrE9.b1:
  • rh_right_mv
  • temp_air_left
  • temp_trh_left_rr
  • temp_trh_right_rr
  • temp_air_right
  • rh_left_mv

sgp30ebbrE9.b1:
  • latent_heat_flux
  • bowen_ratio
  • temp_air_bottom
  • vapor_pressure_bottom
  • temp_trh_top
  • temp_trh_bottom
  • rh_top_fraction
  • temp_air_top
  • sensible_heat_flux
  • vapor_pressure_top
  • rh_bottom_fraction

sgp5ebbrE9.a1:
  • top vapor pressure(vp_top)
  • top air temperature(tair_top)
  • Top humidity(hum_top)
  • bottom air temperature(tair_bot)
  • Bottom humidity(hum_bot)
  • bottom vapor pressure(vp_bot)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • Temperature of the top humidity chamber(thum_top)

sgp15ebbrE9.a1:
  • Left air temperature(tair_l)
  • Temperature of right humidity sensor chamber(rr_thum_r)
  • Right relative humidity(mv_hum_r)
  • Temperature of left humidity sensor chamber(rr_thum_l)
  • Right air temperature(tair_r)
  • Left relative humidity(mv_hum_l)

sgp30ebbrE9.a1:
  • latent heat flux(e)
  • top air temperature(tair_top)
  • Temperature of the top humidity chamber(thum_top)
  • Bottom humidity(hum_bot)
  • Top humidity(hum_top)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • bottom air temperature(tair_bot)
  • bottom vapor pressure(vp_bot)
  • h(h)
  • top vapor pressure(vp_top)
  • ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)


Back To Table of Contents

DQRID : D030919.7
Start DateStart TimeEnd DateEnd Time
08/02/2003060008/04/20031800
Subject:
SGP/EBBR/E9  - Water in Net Radiometer; Surface Fluxes are Incorrect
DataStreams:sgp15ebbrE9.a1, sgp15ebbrE9.b1, sgp30ebbrE9.a1, sgp30ebbrE9.b1, sgp5ebbrE9.a1
Description:
The net radiometer top dome was punctured by migrating birds.  This alone does not cause 
incorrect net radiation measurements.  However, when it subsequently rains, water collects 
in the bottom dome, causing the net radiation measurements to be too large during the 
day and too small at night.
Measurements:sgp15ebbrE9.b1:
  • net_radiation_mv

sgp30ebbrE9.b1:
  • latent_heat_flux
  • net_radiation
  • sensible_heat_flux

sgp5ebbrE9.a1:
  • net radiation(q)

sgp15ebbrE9.a1:
  • Net radiation(mv_q)

sgp30ebbrE9.a1:
  • net radiation(q)
  • h(h)
  • latent heat flux(e)


Back To Table of Contents

DQRID : D031031.3
Start DateStart TimeEnd DateEnd Time
09/23/2003160009/23/20031600
Subject:
SGP/EBBR/E9  - Measurements All Zero
DataStreams:sgp15ebbrE9.a1, sgp15ebbrE9.b1, sgp30ebbrE9.a1, sgp30ebbrE9.b1, sgp5ebbrE9.a1
Description:
Data values were all zero after restarting the CR10 datalogger.
Measurements:sgp15ebbrE9.b1:
  • soil_heat_flow_4_mv
  • soil_moisture_1_rr
  • soil_moisture_4_rr
  • soil_temp_4_rr
  • soil_moisture_2_rr
  • soil_heat_flow_5_mv
  • temp_trh_left_rr
  • net_radiation_mv
  • soil_moisture_5_rr
  • soil_heat_flow_3_mv
  • battery_voltage
  • temp_air_right
  • soil_temp_2_rr
  • soil_heat_flow_2_mv
  • rh_right_mv
  • wspd_arith_mean
  • temp_trh_right_rr
  • soil_moisture_3_rr
  • soil_temp_3_rr
  • wdir_vec_mean_mv
  • atmos_pressure_mv
  • soil_temp_5_rr
  • soil_temp_1_rr
  • temp_air_left
  • soil_heat_flow_1_mv
  • home_signal
  • temp_reference_rr
  • rh_left_mv

sgp30ebbrE9.b1:
  • soil_moisture_2
  • soil_temp_2
  • soil_temp_5
  • bowen_ratio
  • temp_trh_top
  • corr_soil_heat_flow_1
  • soil_heat_flow_1
  • temp_reference
  • vapor_pressure_top
  • wdir_vec_mean
  • soil_moisture_4
  • soil_moisture_3
  • Barometric Pressure(atmos_pressure)
  • soil_heat_capacity_1
  • corr_soil_heat_flow_4
  • energy_storage_change_5
  • energy_storage_change_4
  • soil_heat_flow_5
  • wdir_vec_std
  • temp_trh_bottom
  • energy_storage_change_2
  • temp_air_top
  • net_radiation
  • sensible_heat_flux
  • soil_heat_capacity_4
  • surface_soil_heat_flux_avg
  • soil_heat_flow_4
  • surface_soil_heat_flux_5
  • soil_heat_capacity_2
  • corr_soil_heat_flow_5
  • soil_moisture_5
  • soil_heat_flow_2
  • home_signal_30
  • energy_storage_change_3
  • soil_heat_capacity_3
  • home_signal_15
  • surface_soil_heat_flux_1
  • rh_top_fraction
  • surface_soil_heat_flux_2
  • soil_heat_capacity_5
  • surface_soil_heat_flux_4
  • soil_heat_flow_3
  • corr_soil_heat_flow_3
  • latent_heat_flux
  • temp_air_bottom
  • soil_temp_3
  • vapor_pressure_bottom
  • corr_soil_heat_flow_2
  • wspd_arith_mean
  • surface_soil_heat_flux_3
  • soil_moisture_1
  • rh_bottom_fraction
  • wspd_vec_mean
  • soil_temp_4
  • soil_temp_1
  • energy_storage_change_1

sgp5ebbrE9.a1:
  • vector wind speed(res_ws)
  • Home signal(home)
  • Top humidity(hum_top)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • standard deviation of wind direction (sigma theta)(sigma_wd)
  • bottom air temperature(tair_bot)
  • wind direction (relative to true north)(wind_d)
  • top vapor pressure(vp_top)
  • top air temperature(tair_top)
  • bottom vapor pressure(vp_bot)
  • Retrieved pressure profile(pres)
  • Reference Thermistor Temperature(tref)
  • Bottom humidity(hum_bot)
  • scalar wind speed(wind_s)
  • net radiation(q)
  • Temperature of the top humidity chamber(thum_top)

sgp15ebbrE9.a1:
  • Left air temperature(tair_l)
  • Soil moisture 3(r_sm3)
  • Temperature of right humidity sensor chamber(rr_thum_r)
  • Soil moisture 2(r_sm2)
  • Soil moisture 1(rr_sm1)
  • Soil moisture 4(rr_sm4)
  • Soil moisture 2(rr_sm2)
  • Soil moisture 3(rr_sm3)
  • Soil moisture 5(rr_sm5)
  • Reference temperature(rr_tref)
  • Soil moisture 4(r_sm4)
  • Soil temperature 5(rr_ts5)
  • Wind direction (relative to true north)(mv_wind_d)
  • Soil temperature 4(rr_ts4)
  • Left relative humidity(mv_hum_l)
  • Soil heat flow 4(mv_hft4)
  • Soil moisture 5(r_sm5)
  • Battery(bat)
  • Soil temperature 2(rr_ts2)
  • Home signal(mv_home)
  • Temperature of left humidity sensor chamber(rr_thum_l)
  • Right air temperature(tair_r)
  • Soil temperature 3(rr_ts3)
  • Right relative humidity(mv_hum_r)
  • Soil temperature 1(rr_ts1)
  • Soil heat flow 1(mv_hft1)
  • scalar wind speed(wind_s)
  • Soil heat flow 5(mv_hft5)
  • Atmospheric pressure(mv_pres)
  • Soil heat flow 3(mv_hft3)
  • Net radiation(mv_q)
  • Soil moisture 1(r_sm1)
  • Soil heat flow 2(mv_hft2)

sgp30ebbrE9.a1:
  • 0-5 cm change in soil heat storage with time, site 2(ces2)
  • soil heat flow, site 4(g4)
  • soil heat flow, site 1(g1)
  • 0-5 cm change in soil heat storage with time, site 2(ces1)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • h(h)
  • 5 cm soil heat flow, site 1(shf1)
  • soil heat flow, site 5(g5)
  • 0-5 cm integrated soil temperature, site 2(ts1)
  • soil heat flow, site 2(g2)
  • latent heat flux(e)
  • 0-5 cm change in soil heat storage with time, site 4(ces4)
  • 0-5 cm integrated soil temperature, site 5(ts5)
  • 0-5 cm change in soil heat storage with time, site 5(ces5)
  • wind direction (relative to true north)(wind_d)
  • Soil heat capacity 3(cs3)
  • Exchange mechanism position indicator (0 to 15 min)(home_15)
  • 5 cm soil heat flow, site 4(shf4)
  • 0-5 cm integrated soil temperature, site 3(ts3)
  • Soil heat capacity 2(cs2)
  • top vapor pressure(vp_top)
  • Soil heat capacity 1(cs1)
  • 0-5 cm change in soil heat storage with time, site 3(ces3)
  • soil heat flow, site 3(g3)
  • net radiation(q)
  • 5 cm soil heat flow corrected for soil moisture content, site 3(c_shf3)
  • Reference Thermistor Temperature(tref)
  • standard deviation of wind direction (sigma theta)(sigma_wd)
  • Soil heat capacity 4(cs4)
  • 5 cm soil heat flow corrected for soil moisture content, site 4(c_shf4)
  • volumetric soil moisture, site 3(sm3)
  • average surface soil heat flow(ave_shf)
  • volumetric soil moisture, site 4(sm4)
  • 5 cm soil heat flow corrected for soil moisture content, site 5(c_shf5)
  • 5 cm soil heat flow, site 5(shf5)
  • Bottom humidity(hum_bot)
  • 0-5 cm integrated soil temperature, site 2(ts2)
  • Soil heat capacity 5(cs5)
  • scalar wind speed(wind_s)
  • 5 cm soil heat flow, site 2(shf2)
  • 5 cm soil heat flow corrected for soil moisture content, site 2(c_shf2)
  • 5 cm soil heat flow, site 3(shf3)
  • bottom air temperature(tair_bot)
  • 0-5 cm integrated soil temperature, site 4(ts4)
  • bottom vapor pressure(vp_bot)
  • Retrieved pressure profile(pres)
  • volumetric soil moisture, site 5(sm5)
  • Exchange mechanism position indicator (15 to 30 min)(home_30)
  • vector wind speed(res_ws)
  • top air temperature(tair_top)
  • Temperature of the top humidity chamber(thum_top)
  • Top humidity(hum_top)
  • volumetric soil moisture, site 1(sm1)
  • 5 cm soil heat flow corrected for soil moisture content, site 1(c_shf1)
  • ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)
  • volumetric soil moisture, site 2(sm2)


Back To Table of Contents

DQRID : D031204.8
Start DateStart TimeEnd DateEnd Time
11/04/2003173011/04/20031800
Subject:
SGP/EBBR/E9 - 6 Month Checks
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp15ebbrE9.b1:
  • rh_right_mv
  • temp_air_left
  • temp_trh_left_rr
  • temp_trh_right_rr
  • temp_air_right
  • rh_left_mv

sgp5ebbrE9.b1:
  • vapor_pressure_bottom
  • vapor_pressure_top
  • temp_air_top
  • temp_trh_bottom
  • temp_air_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • temp_trh_top

sgp30ebbrE9.b1:
  • latent_heat_flux
  • bowen_ratio
  • temp_air_bottom
  • vapor_pressure_bottom
  • temp_trh_top
  • temp_trh_bottom
  • rh_top_fraction
  • temp_air_top
  • sensible_heat_flux
  • vapor_pressure_top
  • rh_bottom_fraction


Back To Table of Contents

DQRID : D031222.13
Start DateStart TimeEnd DateEnd Time
12/14/2003010012/14/20031930
Subject:
SGP/EBBR/E9  - Net Radiometer Iced Over During Storm
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
The net radiometer was covered with ice from a storm.  Net radiation values are incorrect, 
and are sometimes even negative during the daytime.  Sensible and latent heat fluxes are 
therefore incorrect.
Measurements:sgp15ebbrE9.b1:
  • net_radiation_mv

sgp5ebbrE9.b1:
  • net_radiation

sgp30ebbrE9.b1:
  • latent_heat_flux
  • net_radiation
  • sensible_heat_flux


Back To Table of Contents

DQRID : D031222.14
Start DateStart TimeEnd DateEnd Time
12/09/2003202012/10/20030645
Subject:
SGP/EBBR/E9 - Wind Speed Sensor Frozen By Ice Storm
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
The wind speed sensor was frozen stopped by ice from a storm.  The wind speed 
and residual wind speed measurements are incorrect.
Measurements:sgp15ebbrE9.b1:
  • wspd_arith_mean

sgp5ebbrE9.b1:
  • wspd_vec_mean
  • wspd_arith_mean

sgp30ebbrE9.b1:
  • wspd_vec_mean
  • wspd_arith_mean


Back To Table of Contents

DQRID : D040304.8
Start DateStart TimeEnd DateEnd Time
01/27/2004174501/27/20041800
01/27/2004193501/28/20040140
01/28/2004033001/28/20040355
01/31/2004180002/12/20041640
Subject:
SGP/EBBR/E9  - Wind Speed Frozen Stopped By Ice
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition. The bearings
in the sensor appear to be worn, contributing to the problem.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp15ebbrE9.b1:
  • wspd_arith_mean

sgp5ebbrE9.b1:
  • wspd_vec_mean
  • wspd_arith_mean

sgp30ebbrE9.b1:
  • wspd_vec_mean
  • wspd_arith_mean


Back To Table of Contents

DQRID : D051112.6
Start DateStart TimeEnd DateEnd Time
10/13/2003000004/19/20052359
Subject:
SGP/EBBR/E9 - metadata corrections
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
On 20050420, a series of metadata corrections and additions were completed.  These 
metadata changes apply to all EBBR.E9 data collected by ARM back to the installation of the 
instrument in December 1992. Please see the current metadata for correct information.  These 
changes do not affect data values or quality.	

The changes are summarized below:
1) Update of "sensor location" information
2) Addition of installation dates for the systems
3) Correction of soil moisture units (from "by volume" to "gravimetric")
Measurements:sgp15ebbrE9.b1:
  • base time(base_time)

sgp5ebbrE9.b1:
  • base time(base_time)

sgp30ebbrE9.b1:
  • base time(base_time)


Back To Table of Contents



END OF DATA