Data Quality Reports for Session: 119342 User: dmfoper Completed: 05/03/2009


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D030919.12SGP/EBBR/E27 - Water in Net Radiometer; Surface Fluxes are Incorrectsgp15ebbrE27.a1, sgp15ebbrE27.b1, sgp30ebbrE27.a1, sgp30ebbrE27.b1, sgp5ebbrE27.a1
D030919.13SGP/EBBR/E27 - 15 and 30 Minute Data All Zerossgp15ebbrE27.a1, sgp15ebbrE27.b1, sgp30ebbrE27.a1, sgp30ebbrE27.b1
D030922.7SGP/EBBR/E27 - Right Air Temperature Spiked Offscalesgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D031021.3SGP/EBBR/E27 - Missing data during system updatesgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D031117.3SGP/EBBR/E27 - Right Air Temperature Spiked Offscalesgp15ebbrE27.a1, sgp15ebbrE27.b1, sgp30ebbrE27.a1, sgp30ebbrE27.b1, sgp5ebbrE27.a1
D031204.22SGP/EBBR/E27 - 6 Month Checkssgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D031210.1SGP/EBBR/E27 - Reprocess: Soil Heat Flow #5 Offscale, Surface Fluxes Incorrectsgp15ebbrE27.a1, sgp15ebbrE27.b1, sgp30ebbrE27.a1, sgp30ebbrE27.b1
D031222.26SGP/EBBR/E27 - Soil Temperature #3 Spike in Datasgp15ebbrE27.b1, sgp30ebbrE27.b1
D040304.25SGP/EBBR/E27 - Wind Speed Frozen Stopped By Icesgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D040318.13SGP/EBBR/E27 - Soil Moisture #5 Insensitivesgp30ebbrE27.b1
D040507.3SGP/EBBR/E27 - Right Air Temperature Incorrectsgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D040706.3SGP/EBBR/E27 - Loose Tair Left Connectionssgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D041222.19SGP/EBBR/E27 - 6 Month Checkssgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D050206.17SGP/EBBR/E27 - Wind Speed Frozen Stopped By Ice Stormsgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D050207.13SGP/EBBR/E27 - Wind Direction Frozen Stopped By Ice Stormsgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D050211.2SGP/EBBR/E27 - Soil Moisture #5 Incorrectsgp30ebbrE27.b1
D050413.6SGP/EBBR/E27 - SM2 Coefficients Incorectsgp15ebbrE27.b1, sgp30ebbrE27.b1
D050719.16SGP/EBBR/E27 - Improved EBBR CR10 Programsgp30ebbrE27.b1
D051106.15SGP/EBBR/E27 - Net Radiation Incorrect; Sensible and Latent Heat Fluxes Incorrectsgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D051106.16SGP/EBBR/E27 - Net Radiation Incorrect; Sensible and Latent Heat Fluxes Incorredtsgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D051106.31SGP/EBBR/E27 - Average Soil Heat Flux Incorrectsgp30ebbrE27.b1
D051112.10SGP/EBBR/E27 - metadata correctionssgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D060425.1SGP/EBBR/E27 - Sensible and Latent Heat Fluxes Incorrectsgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D060501.27SGP/EBBR/E27 - Flux and Gradient Measurements Incorrectsgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D060508.3SGP/EBBR/E27 - Instrument problem, Loose connectionssgp15ebbrE27.b1, sgp30ebbrE27.b1
D060818.11SGP/EBBR/E27 - Most Measurements Suspectsgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1


DQRID : D030919.12
Start DateStart TimeEnd DateEnd Time
08/30/2003063009/03/20031700
Subject:
SGP/EBBR/E27  - Water in Net Radiometer; Surface Fluxes are Incorrect
DataStreams:sgp15ebbrE27.a1, sgp15ebbrE27.b1, sgp30ebbrE27.a1, sgp30ebbrE27.b1, sgp5ebbrE27.a1
Description:
The net radiometer top dome was punctured by migrating birds.  This alone does not cause 
incorrect net radiation measurements.  However, when it subsequently rains, water collects 
in the bottom dome, causing the net radiation measurements to be too large during the 
day and too small at night.
Measurements:sgp30ebbrE27.a1:
  • h(h)
  • latent heat flux(e)
  • net radiation(q)

sgp15ebbrE27.a1:
  • Net radiation(mv_q)

sgp5ebbrE27.a1:
  • net radiation(q)

sgp30ebbrE27.b1:
  • latent_heat_flux
  • sensible_heat_flux
  • net_radiation

sgp15ebbrE27.b1:
  • net_radiation_mv


Back To Table of Contents

DQRID : D030919.13
Start DateStart TimeEnd DateEnd Time
08/20/2003160008/20/20031600
Subject:
SGP/EBBR/E27  - 15 and 30 Minute Data All Zeros
DataStreams:sgp15ebbrE27.a1, sgp15ebbrE27.b1, sgp30ebbrE27.a1, sgp30ebbrE27.b1
Description:
15 and 30 minute measurements were all zero after restarting the CR10 datalogger.
Measurements:sgp30ebbrE27.a1:
  • volumetric soil moisture, site 5(sm5)
  • bottom vapor pressure(vp_bot)
  • volumetric soil moisture, site 4(sm4)
  • Soil heat capacity 4(cs4)
  • 0-5 cm integrated soil temperature, site 2(ts1)
  • top vapor pressure(vp_top)
  • volumetric soil moisture, site 2(sm2)
  • wind direction (relative to true north)(wind_d)
  • 5 cm soil heat flow, site 1(shf1)
  • 5 cm soil heat flow corrected for soil moisture content, site 4(c_shf4)
  • top air temperature(tair_top)
  • 5 cm soil heat flow corrected for soil moisture content, site 3(c_shf3)
  • scalar wind speed(wind_s)
  • 5 cm soil heat flow, site 2(shf2)
  • Soil heat capacity 3(cs3)
  • bottom air temperature(tair_bot)
  • 0-5 cm integrated soil temperature, site 4(ts4)
  • Top humidity(hum_top)
  • 0-5 cm change in soil heat storage with time, site 2(ces2)
  • 0-5 cm change in soil heat storage with time, site 3(ces3)
  • 5 cm soil heat flow, site 3(shf3)
  • net radiation(q)
  • Temperature of the top humidity chamber(thum_top)
  • 5 cm soil heat flow corrected for soil moisture content, site 5(c_shf5)
  • soil heat flow, site 4(g4)
  • Soil heat capacity 5(cs5)
  • 0-5 cm integrated soil temperature, site 2(ts2)
  • soil heat flow, site 5(g5)
  • 0-5 cm integrated soil temperature, site 5(ts5)
  • Reference Thermistor Temperature(tref)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • Bottom humidity(hum_bot)
  • soil heat flow, site 3(g3)
  • 0-5 cm integrated soil temperature, site 3(ts3)
  • Soil heat capacity 1(cs1)
  • soil heat flow, site 2(g2)
  • standard deviation of wind direction (sigma theta)(sigma_wd)
  • average surface soil heat flow(ave_shf)
  • ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)
  • Soil heat capacity 2(cs2)
  • 5 cm soil heat flow corrected for soil moisture content, site 2(c_shf2)
  • 0-5 cm change in soil heat storage with time, site 5(ces5)
  • 5 cm soil heat flow, site 5(shf5)
  • Exchange mechanism position indicator (15 to 30 min)(home_30)
  • 5 cm soil heat flow corrected for soil moisture content, site 1(c_shf1)
  • h(h)
  • latent heat flux(e)
  • soil heat flow, site 1(g1)
  • 5 cm soil heat flow, site 4(shf4)
  • 0-5 cm change in soil heat storage with time, site 4(ces4)
  • Exchange mechanism position indicator (0 to 15 min)(home_15)
  • Retrieved pressure profile(pres)
  • 0-5 cm change in soil heat storage with time, site 2(ces1)
  • vector wind speed(res_ws)
  • volumetric soil moisture, site 1(sm1)
  • volumetric soil moisture, site 3(sm3)

sgp15ebbrE27.a1:
  • Soil moisture 5(r_sm5)
  • scalar wind speed(wind_s)
  • Soil moisture 3(r_sm3)
  • Soil temperature 5(rr_ts5)
  • Soil moisture 4(r_sm4)
  • Battery(bat)
  • Right relative humidity(mv_hum_r)
  • Temperature of right humidity sensor chamber(rr_thum_r)
  • Soil temperature 3(rr_ts3)
  • Soil temperature 2(rr_ts2)
  • Left relative humidity(mv_hum_l)
  • Soil heat flow 4(mv_hft4)
  • Soil temperature 4(rr_ts4)
  • Soil heat flow 5(mv_hft5)
  • Soil temperature 1(rr_ts1)
  • Net radiation(mv_q)
  • Soil moisture 1(r_sm1)
  • Soil heat flow 2(mv_hft2)
  • Left air temperature(tair_l)
  • Soil heat flow 1(mv_hft1)
  • Reference temperature(rr_tref)
  • Right air temperature(tair_r)
  • Soil moisture 2(r_sm2)
  • Home signal(mv_home)
  • Wind direction (relative to true north)(mv_wind_d)
  • Atmospheric pressure(mv_pres)
  • Soil heat flow 3(mv_hft3)
  • Temperature of left humidity sensor chamber(rr_thum_l)

sgp30ebbrE27.b1:
  • soil_heat_flow_4
  • Barometric Pressure(atmos_pressure)
  • soil_moisture_3
  • soil_heat_flow_5
  • vapor_pressure_bottom
  • sensible_heat_flux
  • surface_soil_heat_flux_5
  • temp_air_bottom
  • energy_storage_change_2
  • energy_storage_change_3
  • soil_heat_capacity_3
  • soil_temp_2
  • soil_heat_capacity_1
  • soil_temp_1
  • wdir_vec_mean
  • surface_soil_heat_flux_4
  • soil_heat_capacity_2
  • net_radiation
  • soil_temp_3
  • soil_moisture_1
  • corr_soil_heat_flow_4
  • wdir_vec_std
  • soil_moisture_2
  • home_signal_15
  • soil_temp_5
  • surface_soil_heat_flux_3
  • energy_storage_change_1
  • home_signal_30
  • corr_soil_heat_flow_3
  • soil_temp_4
  • temp_trh_bottom
  • soil_heat_flow_3
  • wspd_vec_mean
  • corr_soil_heat_flow_5
  • soil_heat_flow_2
  • surface_soil_heat_flux_1
  • corr_soil_heat_flow_1
  • soil_heat_capacity_4
  • temp_reference
  • energy_storage_change_4
  • vapor_pressure_top
  • soil_heat_flow_1
  • latent_heat_flux
  • soil_heat_capacity_5
  • corr_soil_heat_flow_2
  • temp_air_top
  • soil_moisture_5
  • energy_storage_change_5
  • surface_soil_heat_flux_2
  • temp_trh_top
  • rh_top_fraction
  • surface_soil_heat_flux_avg
  • bowen_ratio
  • rh_bottom_fraction
  • wspd_arith_mean
  • soil_moisture_4

sgp15ebbrE27.b1:
  • battery_voltage
  • temp_air_right
  • soil_heat_flow_1_mv
  • soil_moisture_1_rr
  • soil_temp_3_rr
  • soil_temp_4_rr
  • soil_moisture_5_rr
  • soil_temp_1_rr
  • soil_heat_flow_2_mv
  • temp_reference_rr
  • soil_temp_5_rr
  • home_signal
  • soil_moisture_4_rr
  • soil_heat_flow_5_mv
  • rh_left_mv
  • soil_heat_flow_4_mv
  • net_radiation_mv
  • temp_air_left
  • rh_right_mv
  • wdir_vec_mean_mv
  • atmos_pressure_mv
  • wspd_arith_mean
  • soil_moisture_3_rr
  • soil_moisture_2_rr
  • temp_trh_left_rr
  • soil_temp_2_rr
  • temp_trh_right_rr
  • soil_heat_flow_3_mv


Back To Table of Contents

DQRID : D030922.7
Start DateStart TimeEnd DateEnd Time
10/15/2003103011/17/20030630
Subject:
SGP/EBBR/E27 - Right Air Temperature Spiked Offscale
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
The right air temperature was going offscale at times.
This problem seemed to end without Site Ops. intervention.
Measurements:sgp5ebbrE27.b1:
  • temp_air_bottom
  • temp_air_top

sgp30ebbrE27.b1:
  • latent_heat_flux
  • sensible_heat_flux
  • bowen_ratio
  • temp_air_top
  • temp_air_bottom

sgp15ebbrE27.b1:
  • temp_air_right


Back To Table of Contents

DQRID : D031021.3
Start DateStart TimeEnd DateEnd Time
10/29/2003170010/29/20031930
Subject:
SGP/EBBR/E27 - Missing data during system update
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
Some soil parameters were slightly incorrect since EBBR.E27 was 
                 installed in May 2003.  While the coefficients were being updated,
                 data collection was suspended resulting in missing data for the 
                 specified period.
                    No significant effects (1% or less) on the surface heat flux data 
                 would have occurred from using the slightly incorrect coefficients. 
                 Therefore, flagging of the surface flux data from the time of 
                 installation of E27 is unwarranted.
Measurements:sgp5ebbrE27.b1:
  • Dummy altitude for Zeb(alt)
  • wspd_arith_mean
  • vapor_pressure_bottom
  • wdir_vec_mean
  • home_signal
  • temp_air_bottom
  • rh_top_fraction
  • net_radiation
  • lat(lat)
  • Time offset of tweaks from base_time(time_offset)
  • Barometric Pressure(atmos_pressure)
  • vapor_pressure_top
  • temp_reference
  • wdir_vec_std
  • rh_bottom_fraction
  • time(time)
  • base time(base_time)
  • wspd_vec_mean
  • temp_trh_top
  • lon(lon)
  • temp_air_top
  • temp_trh_bottom

sgp30ebbrE27.b1:
  • soil_heat_flow_4
  • Barometric Pressure(atmos_pressure)
  • soil_moisture_3
  • soil_heat_flow_5
  • vapor_pressure_bottom
  • sensible_heat_flux
  • surface_soil_heat_flux_5
  • temp_air_bottom
  • energy_storage_change_2
  • energy_storage_change_3
  • soil_heat_capacity_3
  • soil_temp_2
  • soil_temp_1
  • soil_heat_capacity_1
  • wdir_vec_mean
  • surface_soil_heat_flux_4
  • net_radiation
  • soil_heat_capacity_2
  • soil_temp_3
  • soil_moisture_1
  • corr_soil_heat_flow_4
  • wdir_vec_std
  • soil_moisture_2
  • home_signal_15
  • lat(lat)
  • soil_temp_5
  • surface_soil_heat_flux_3
  • energy_storage_change_1
  • Dummy altitude for Zeb(alt)
  • home_signal_30
  • corr_soil_heat_flow_3
  • soil_temp_4
  • temp_trh_bottom
  • wspd_vec_mean
  • soil_heat_flow_3
  • corr_soil_heat_flow_5
  • base time(base_time)
  • soil_heat_flow_2
  • surface_soil_heat_flux_1
  • corr_soil_heat_flow_1
  • soil_heat_capacity_4
  • temp_reference
  • lon(lon)
  • Time offset of tweaks from base_time(time_offset)
  • energy_storage_change_4
  • vapor_pressure_top
  • soil_heat_flow_1
  • latent_heat_flux
  • soil_heat_capacity_5
  • corr_soil_heat_flow_2
  • temp_air_top
  • soil_moisture_5
  • energy_storage_change_5
  • surface_soil_heat_flux_2
  • temp_trh_top
  • rh_top_fraction
  • surface_soil_heat_flux_avg
  • bowen_ratio
  • rh_bottom_fraction
  • wspd_arith_mean
  • soil_moisture_4

sgp15ebbrE27.b1:
  • battery_voltage
  • temp_air_right
  • soil_heat_flow_1_mv
  • lat(lat)
  • soil_moisture_1_rr
  • lon(lon)
  • soil_temp_3_rr
  • soil_temp_4_rr
  • base time(base_time)
  • soil_moisture_5_rr
  • soil_temp_1_rr
  • soil_heat_flow_2_mv
  • Time offset of tweaks from base_time(time_offset)
  • temp_reference_rr
  • soil_temp_5_rr
  • home_signal
  • soil_moisture_4_rr
  • soil_heat_flow_5_mv
  • rh_left_mv
  • soil_heat_flow_4_mv
  • Dummy altitude for Zeb(alt)
  • net_radiation_mv
  • temp_air_left
  • rh_right_mv
  • wdir_vec_mean_mv
  • atmos_pressure_mv
  • wspd_arith_mean
  • soil_moisture_3_rr
  • soil_temp_2_rr
  • temp_trh_left_rr
  • soil_moisture_2_rr
  • temp_trh_right_rr
  • soil_heat_flow_3_mv


Back To Table of Contents

DQRID : D031117.3
Start DateStart TimeEnd DateEnd Time
09/06/2003120010/11/20030730
Subject:
SGP/EBBR/E27 - Right Air Temperature Spiked Offscale
DataStreams:sgp15ebbrE27.a1, sgp15ebbrE27.b1, sgp30ebbrE27.a1, sgp30ebbrE27.b1, sgp5ebbrE27.a1
Description:
The right air temperature was going offscale at times.
Measurements:sgp30ebbrE27.a1:
  • bottom air temperature(tair_bot)
  • latent heat flux(e)
  • h(h)
  • ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)
  • top air temperature(tair_top)

sgp15ebbrE27.a1:
  • Right air temperature(tair_r)

sgp5ebbrE27.a1:
  • top air temperature(tair_top)
  • bottom air temperature(tair_bot)

sgp30ebbrE27.b1:
  • latent_heat_flux
  • sensible_heat_flux
  • bowen_ratio
  • temp_air_top
  • temp_air_bottom

sgp15ebbrE27.b1:
  • temp_air_right


Back To Table of Contents

DQRID : D031204.22
Start DateStart TimeEnd DateEnd Time
10/29/2003183010/29/20031945
Subject:
SGP/EBBR/E27 - 6 Month Checks
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp5ebbrE27.b1:
  • rh_bottom_fraction
  • temp_air_bottom
  • rh_top_fraction
  • temp_trh_top
  • temp_air_top
  • vapor_pressure_bottom
  • temp_trh_bottom
  • vapor_pressure_top

sgp30ebbrE27.b1:
  • latent_heat_flux
  • temp_trh_bottom
  • temp_air_top
  • vapor_pressure_bottom
  • sensible_heat_flux
  • temp_trh_top
  • rh_top_fraction
  • bowen_ratio
  • rh_bottom_fraction
  • vapor_pressure_top
  • temp_air_bottom

sgp15ebbrE27.b1:
  • temp_air_left
  • temp_air_right
  • rh_right_mv
  • rh_left_mv
  • temp_trh_left_rr
  • temp_trh_right_rr


Back To Table of Contents

DQRID : D031210.1
Start DateStart TimeEnd DateEnd Time
09/12/2003170010/12/20032359
Subject:
SGP/EBBR/E27 - Reprocess: Soil Heat Flow #5 Offscale, Surface Fluxes Incorrect
DataStreams:sgp15ebbrE27.a1, sgp15ebbrE27.b1, sgp30ebbrE27.a1, sgp30ebbrE27.b1
Description:
Soil Heat Flow #5 went offscale at times.

Latent and Sensible Heat Fluxes were incorrect when this occurred.
Measurements:sgp30ebbrE27.a1:
  • 5 cm soil heat flow, site 5(shf5)
  • average surface soil heat flow(ave_shf)
  • 5 cm soil heat flow corrected for soil moisture content, site 5(c_shf5)
  • latent heat flux(e)
  • h(h)
  • soil heat flow, site 5(g5)

sgp15ebbrE27.a1:
  • Soil heat flow 5(mv_hft5)

sgp30ebbrE27.b1:
  • latent_heat_flux
  • sensible_heat_flux
  • surface_soil_heat_flux_avg
  • surface_soil_heat_flux_5
  • corr_soil_heat_flow_5
  • soil_heat_flow_5

sgp15ebbrE27.b1:
  • soil_heat_flow_5_mv


Back To Table of Contents

DQRID : D031222.26
Start DateStart TimeEnd DateEnd Time
12/06/2003090012/06/20030900
Subject:
SGP/EBBR/E27 - Soil Temperature #3 Spike in Data
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1
Description:
The soil temperature #3 spiked to zero and was therefore incorrect.
Measurements:sgp30ebbrE27.b1:
  • latent_heat_flux
  • sensible_heat_flux
  • surface_soil_heat_flux_avg
  • energy_storage_change_3
  • soil_temp_3
  • surface_soil_heat_flux_3

sgp15ebbrE27.b1:
  • soil_temp_3_rr


Back To Table of Contents

DQRID : D040304.25
Start DateStart TimeEnd DateEnd Time
02/02/2004070502/02/20041800
02/05/2004020502/05/20040600
Subject:
SGP/EBBR/E27  - Wind Speed Frozen Stopped By Ice
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp30ebbrE27.b1:
  • wspd_arith_mean
  • wspd_vec_mean

sgp5ebbrE27.b1:
  • wspd_arith_mean
  • wspd_vec_mean

sgp15ebbrE27.b1:
  • wspd_arith_mean


Back To Table of Contents

DQRID : D040318.13
Start DateStart TimeEnd DateEnd Time
01/25/2004060005/12/20041930
Subject:
SGP/EBBR/E27 - Soil Moisture #5 Insensitive
DataStreams:sgp30ebbrE27.b1
Description:
Soil moisture sensor #5 was insensitive and put out a value of around 30%.

Sensible and latent heat fluxes were not significantly affected by this
small error.
Measurements:sgp30ebbrE27.b1:
  • corr_soil_heat_flow_5
  • soil_heat_capacity_5
  • soil_moisture_5
  • energy_storage_change_5
  • surface_soil_heat_flux_5


Back To Table of Contents

DQRID : D040507.3
Start DateStart TimeEnd DateEnd Time
03/01/2004000003/31/20042355
Subject:
SGP/EBBR/E27  - Right Air Temperature Incorrect
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
The right air temperature, and therefore top and bottom air temperatures
were offscale or incorrect on occasion.  Bowen ratio, sensible heat flux, and latent heat 
flux were also incorrect during those times.

Inspection of the data is required to detect the incorrect periods.
Measurements:sgp5ebbrE27.b1:
  • temp_air_bottom
  • temp_air_top

sgp30ebbrE27.b1:
  • latent_heat_flux
  • sensible_heat_flux
  • bowen_ratio
  • temp_air_top
  • temp_air_bottom

sgp15ebbrE27.b1:
  • temp_air_right


Back To Table of Contents

DQRID : D040706.3
Start DateStart TimeEnd DateEnd Time
06/10/2004060007/21/20041725
Subject:
SGP/EBBR/E27 - Loose Tair Left Connections
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
Tair left dropped out at times. When this occurred, the sensible and latent heat fluxes 
are incorrect.

Tightening of the electronic connections to the datalogging equipment
appears to have solved the problem.
Measurements:sgp5ebbrE27.b1:
  • temp_air_bottom
  • temp_air_top

sgp30ebbrE27.b1:
  • latent_heat_flux
  • sensible_heat_flux
  • bowen_ratio
  • temp_air_top
  • temp_air_bottom

sgp15ebbrE27.b1:
  • temp_air_left


Back To Table of Contents

DQRID : D041222.19
Start DateStart TimeEnd DateEnd Time
09/29/2004200009/29/20042030
Subject:
SGP/EBBR/E27 - 6 Month Checks
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp5ebbrE27.b1:
  • rh_bottom_fraction
  • temp_air_bottom
  • rh_top_fraction
  • temp_trh_top
  • temp_air_top
  • vapor_pressure_bottom
  • temp_trh_bottom
  • vapor_pressure_top

sgp30ebbrE27.b1:
  • latent_heat_flux
  • temp_trh_bottom
  • temp_air_top
  • vapor_pressure_bottom
  • sensible_heat_flux
  • temp_trh_top
  • rh_top_fraction
  • bowen_ratio
  • rh_bottom_fraction
  • vapor_pressure_top
  • temp_air_bottom

sgp15ebbrE27.b1:
  • temp_air_left
  • temp_air_right
  • rh_right_mv
  • rh_left_mv
  • temp_trh_left_rr
  • temp_trh_right_rr


Back To Table of Contents

DQRID : D050206.17
Start DateStart TimeEnd DateEnd Time
01/05/2005155501/07/20051605
Subject:
SGP/EBBR/E27  - Wind Speed Frozen Stopped By Ice Storm
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp30ebbrE27.b1:
  • wspd_arith_mean
  • wspd_vec_mean

sgp5ebbrE27.b1:
  • wspd_arith_mean

sgp15ebbrE27.b1:
  • wspd_arith_mean


Back To Table of Contents

DQRID : D050207.13
Start DateStart TimeEnd DateEnd Time
01/06/2005100501/07/20051430
Subject:
SGP/EBBR/E27  - Wind Direction Frozen Stopped By Ice Storm
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
The wind direction sensor was frozen stopped by ice from a storm.  
The wind direction, sigma_wd, and residual wind speed measurements 
are incorrect.
Measurements:sgp5ebbrE27.b1:
  • wspd_vec_mean
  • wdir_vec_std
  • wdir_vec_mean

sgp30ebbrE27.b1:
  • wdir_vec_std
  • wdir_vec_mean
  • wspd_vec_mean

sgp15ebbrE27.b1:
  • wdir_vec_mean_mv


Back To Table of Contents

DQRID : D050211.2
Start DateStart TimeEnd DateEnd Time
09/15/2004160003/07/20052100
Subject:
SGP/EBBR/E27 - Soil Moisture #5 Incorrect
DataStreams:sgp30ebbrE27.b1
Description:
The wrong CR10 program loaded from the storage module on 9/15/04.  During the previous 
change of program, an attempt was made to store the new program in the storage module; site 
ops techs did not notice that this attempt failed, leaving the old program in the storage 
module.  When power was cyled on 9/15/04, the old program with flat sm5 coefficients 
loaded into the CR10.  The "flat" coefficients resulted in the sm5 soil moisture hovering 
around 30%.

15 minute raw sm5 resistances were correct.

Average soil heat flow, sensible heat flux, and latent heat flux were not
significantly affected and so are not included in the list of incorrect measurements.
Measurements:sgp30ebbrE27.b1:
  • soil_moisture_5


Back To Table of Contents

DQRID : D050413.6
Start DateStart TimeEnd DateEnd Time
03/04/2004164503/02/20051600
Subject:
SGP/EBBR/E27 - SM2 Coefficients Incorect
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1
Description:
Soil Moisture #2 coefficients in the CR10 datalogger program were incorrect during the 
time
that an old program version was installed.
Measurements:sgp30ebbrE27.b1:
  • soil_moisture_2
  • corr_soil_heat_flow_2
  • soil_heat_capacity_2
  • energy_storage_change_2
  • surface_soil_heat_flux_2

sgp15ebbrE27.b1:
  • soil_moisture_2_rr


Back To Table of Contents

DQRID : D050719.16
Start DateStart TimeEnd DateEnd Time
05/07/2003000003/30/20051730
Subject:
SGP/EBBR/E27 - Improved EBBR CR10 Program
DataStreams:sgp30ebbrE27.b1
Description:
Effective 20050330.1730, the EBBR.E27 CR10 program was revised to improve 
the quality of the primary measurements as follows:
   
1) An RMS procedure is used to determine max and min limits of acceptable
soil heat flow.  This is applied to the individual soil sets.  Measurements
outside the limits are rejected and the measurements within the limits are
used to calculate the average soil heat flow.
   
2) Max and min limits are used to determine incorrect values of net
radiation, sensible heat flux (h), latent heat flux (e), and automatic
exchange mechanism (AEM) signal.  If AEM signal is outside the limits, h 
and e are set to 999s.  If net radiation is outside the limits, h and e are 
set to 999s. If h or e are outside the limits, h and e are set to 999s.
   
Virtually no incorrect soil measurement will affect the primary 
measurements of h and e.
   
By setting h and e to 999s, it can be easily seen that the primary 
variables are incorrect; no other interpretation is possible.
   
Prior to 20050330, the improved CR10 program was NOT in effect.  DQRs have
been submitted for known instances of incorrect soil measurements which
affected the quality of the primary measurements of h and e.
   
Note: the DQR begin date is the begin date of the sgp30ebbrE27.b1 data
stream.  The earlier version of the CR10 program was also used on previous
EBBR datastream names (e.g. sgp30ebbrE27.a1).
Measurements:sgp30ebbrE27.b1:
  • latent_heat_flux
  • sensible_heat_flux
  • surface_soil_heat_flux_avg


Back To Table of Contents

DQRID : D051106.15
Start DateStart TimeEnd DateEnd Time
08/05/2005220008/17/20051600
Subject:
SGP/EBBR/E27 - Net Radiation Incorrect; Sensible and Latent Heat Fluxes Incorrect
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
The net radiometer top dome was broken and water got inside, making the net radiation, and 
sensible and latent heat flux measurements incorrect.
Measurements:sgp5ebbrE27.b1:
  • net_radiation

sgp30ebbrE27.b1:
  • latent_heat_flux
  • sensible_heat_flux
  • net_radiation

sgp15ebbrE27.b1:
  • net_radiation_mv


Back To Table of Contents

DQRID : D051106.16
Start DateStart TimeEnd DateEnd Time
08/17/2005163008/27/20051930
Subject:
SGP/EBBR/E27 - Net Radiation Incorrect; Sensible and Latent Heat Fluxes Incorredt
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
Residual Moisture left in the top dome of the net radiometer after the 8/17/05 servicing 
caused the net radiation measurements to be biased low, and resulting in sensible and 
latent heat flux being low also.
Measurements:sgp5ebbrE27.b1:
  • net_radiation

sgp30ebbrE27.b1:
  • latent_heat_flux
  • sensible_heat_flux
  • net_radiation

sgp15ebbrE27.b1:
  • net_radiation_mv


Back To Table of Contents

DQRID : D051106.31
Start DateStart TimeEnd DateEnd Time
03/02/2005160003/30/20051730
Subject:
SGP/EBBR/E27 - Average Soil Heat Flux Incorrect
DataStreams:sgp30ebbrE27.b1
Description:
A typo in the version 9 EBBR program caused average soil heat flow to be zero, resulting 
in both sensible and latent heat fluxes being approximately 20 watts per meter squared too 
large during the middle of the day.
Measurements:sgp30ebbrE27.b1:
  • latent_heat_flux
  • sensible_heat_flux
  • surface_soil_heat_flux_avg


Back To Table of Contents

DQRID : D051112.10
Start DateStart TimeEnd DateEnd Time
10/13/2003000008/16/20052359
Subject:
SGP/EBBR/E27 - metadata corrections
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
On 20050816, a series of metadata corrections and additions were completed.  These 
metadata changes apply to all EBBR.E27 data collected by ARM back to the installation of the 
instrument in May 2003. Please see the current metadata for correct information.  These 
changes do not affect data values or quality.	

The changes are summarized below:
1) Update of "sensor location" information
2) Addition of installation dates for the systems
3) Correction of soil moisture units (from "by volume" to "gravimetric")
Measurements:sgp30ebbrE27.b1:
  • base time(base_time)

sgp5ebbrE27.b1:
  • base time(base_time)

sgp15ebbrE27.b1:
  • base time(base_time)


Back To Table of Contents

DQRID : D060425.1
Start DateStart TimeEnd DateEnd Time
03/03/2006000005/10/20061130
05/25/2006210006/20/20061730
Subject:
SGP/EBBR/E27 - Sensible and Latent Heat Fluxes Incorrect
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
The left T/RH probe temperature sensor was spiking some of the time during these periods. 
Therefore, sensible and latent heat fluxes were incorrect during parts of the periods as 
well.
Measurements:sgp5ebbrE27.b1:
  • vapor_pressure_bottom
  • temp_trh_bottom
  • temp_trh_top
  • vapor_pressure_top

sgp30ebbrE27.b1:
  • latent_heat_flux
  • sensible_heat_flux
  • temp_trh_top
  • vapor_pressure_top
  • temp_trh_bottom
  • bowen_ratio
  • vapor_pressure_bottom

sgp15ebbrE27.b1:
  • temp_trh_left_rr


Back To Table of Contents

DQRID : D060501.27
Start DateStart TimeEnd DateEnd Time
02/18/2006033003/01/20061615
Subject:
SGP/EBBR/E27 - Flux and Gradient Measurements Incorrect
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
The sensible and latent heat flux and gradient measurements were incorrect
while the AEM was hung in one position.
Measurements:sgp5ebbrE27.b1:
  • rh_bottom_fraction
  • temp_air_bottom
  • rh_top_fraction
  • temp_trh_top
  • temp_air_top
  • vapor_pressure_bottom
  • temp_trh_bottom
  • vapor_pressure_top

sgp30ebbrE27.b1:
  • latent_heat_flux
  • temp_trh_bottom
  • temp_air_top
  • vapor_pressure_bottom
  • sensible_heat_flux
  • temp_trh_top
  • rh_top_fraction
  • bowen_ratio
  • rh_bottom_fraction
  • vapor_pressure_top
  • temp_air_bottom

sgp15ebbrE27.b1:
  • temp_air_left
  • temp_air_right
  • rh_right_mv
  • rh_left_mv
  • temp_trh_left_rr
  • temp_trh_right_rr


Back To Table of Contents

DQRID : D060508.3
Start DateStart TimeEnd DateEnd Time
03/09/2006190004/16/20061600
Subject:
SGP/EBBR/E27 - Instrument problem, Loose connections
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1
Description:
The soil heat flow #1 sensor went offscale low on occasion.  This sometimes caused 
sensible and latent heat fluxes to be 9999ed out by the EBBR programming, but not always.
Measurements:sgp30ebbrE27.b1:
  • latent_heat_flux
  • corr_soil_heat_flow_1
  • sensible_heat_flux
  • surface_soil_heat_flux_1
  • soil_heat_flow_1

sgp15ebbrE27.b1:
  • soil_heat_flow_1_mv


Back To Table of Contents

DQRID : D060818.11
Start DateStart TimeEnd DateEnd Time
04/26/2006183008/17/20061730
Subject:
SGP/EBBR/E27 - Most Measurements Suspect
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
The wrong EBBR program was used at this site.  Therefore, most of the measurements are 
suspect.

Note: Mentor reports reprocessing will not correct this problem.
Measurements:sgp5ebbrE27.b1:
  • Dummy altitude for Zeb(alt)
  • wspd_arith_mean
  • vapor_pressure_bottom
  • wdir_vec_mean
  • home_signal
  • temp_air_bottom
  • rh_top_fraction
  • net_radiation
  • lat(lat)
  • Time offset of tweaks from base_time(time_offset)
  • Barometric Pressure(atmos_pressure)
  • vapor_pressure_top
  • temp_reference
  • wdir_vec_std
  • rh_bottom_fraction
  • time(time)
  • base time(base_time)
  • wspd_vec_mean
  • temp_trh_top
  • lon(lon)
  • temp_air_top
  • temp_trh_bottom

sgp30ebbrE27.b1:
  • soil_heat_flow_4
  • Barometric Pressure(atmos_pressure)
  • soil_moisture_3
  • soil_heat_flow_5
  • vapor_pressure_bottom
  • sensible_heat_flux
  • surface_soil_heat_flux_5
  • temp_air_bottom
  • energy_storage_change_2
  • energy_storage_change_3
  • soil_heat_capacity_3
  • soil_temp_2
  • soil_temp_1
  • soil_heat_capacity_1
  • wdir_vec_mean
  • surface_soil_heat_flux_4
  • net_radiation
  • soil_heat_capacity_2
  • soil_temp_3
  • soil_moisture_1
  • corr_soil_heat_flow_4
  • wdir_vec_std
  • soil_moisture_2
  • home_signal_15
  • lat(lat)
  • soil_temp_5
  • surface_soil_heat_flux_3
  • energy_storage_change_1
  • Dummy altitude for Zeb(alt)
  • home_signal_30
  • corr_soil_heat_flow_3
  • soil_temp_4
  • temp_trh_bottom
  • wspd_vec_mean
  • soil_heat_flow_3
  • corr_soil_heat_flow_5
  • base time(base_time)
  • soil_heat_flow_2
  • surface_soil_heat_flux_1
  • corr_soil_heat_flow_1
  • soil_heat_capacity_4
  • temp_reference
  • lon(lon)
  • Time offset of tweaks from base_time(time_offset)
  • energy_storage_change_4
  • vapor_pressure_top
  • soil_heat_flow_1
  • latent_heat_flux
  • soil_heat_capacity_5
  • corr_soil_heat_flow_2
  • temp_air_top
  • soil_moisture_5
  • energy_storage_change_5
  • surface_soil_heat_flux_2
  • temp_trh_top
  • rh_top_fraction
  • surface_soil_heat_flux_avg
  • bowen_ratio
  • rh_bottom_fraction
  • wspd_arith_mean
  • soil_moisture_4

sgp15ebbrE27.b1:
  • battery_voltage
  • temp_air_right
  • soil_heat_flow_1_mv
  • lat(lat)
  • soil_moisture_1_rr
  • lon(lon)
  • soil_temp_3_rr
  • soil_temp_4_rr
  • base time(base_time)
  • soil_moisture_5_rr
  • soil_temp_1_rr
  • soil_heat_flow_2_mv
  • Time offset of tweaks from base_time(time_offset)
  • temp_reference_rr
  • soil_temp_5_rr
  • home_signal
  • soil_moisture_4_rr
  • soil_heat_flow_5_mv
  • rh_left_mv
  • soil_heat_flow_4_mv
  • Dummy altitude for Zeb(alt)
  • net_radiation_mv
  • temp_air_left
  • rh_right_mv
  • wdir_vec_mean_mv
  • atmos_pressure_mv
  • wspd_arith_mean
  • soil_moisture_3_rr
  • soil_temp_2_rr
  • temp_trh_left_rr
  • soil_moisture_2_rr
  • temp_trh_right_rr
  • soil_heat_flow_3_mv


Back To Table of Contents