Data Quality Reports for Session: 119338 User: dmfoper Completed: 05/03/2009


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D011127.33SGP EBBR E25 - E25 EBBR Data Incorrect During 6 Month Checkssgp15ebbrE25.a1, sgp15ebbrE25.b1, sgp30ebbrE25.a1, sgp30ebbrE25.b1, sgp5ebbrE25.a1
D011206.8SGP EBBR E25 - E25 EBBR Soil Heat Flow #3 Incorrectsgp15ebbrE25.a1, sgp15ebbrE25.b1, sgp30ebbrE25.a1, sgp30ebbrE25.b1
D011206.9SGP EBBR E25 - E25 EBBR Soil Heat Flow #1 Incorrectsgp15ebbrE25.a1, sgp15ebbrE25.b1, sgp30ebbrE25.a1, sgp30ebbrE25.b1
D030709.1SGP/EBBR/E25 - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR
Header
sgp30ebbrE25.b1
D051115.10SGP/EBBR/E25 - metadata errorssgp15ebbrE25.b1, sgp30ebbrE25.b1


DQRID : D011127.33
Start DateStart TimeEnd DateEnd Time
04/04/2001153004/04/20011631
10/17/2001170510/17/20011811
Subject:
SGP EBBR E25 - E25 EBBR Data Incorrect During 6 Month Checks
DataStreams:sgp15ebbrE25.a1, sgp15ebbrE25.b1, sgp30ebbrE25.a1, sgp30ebbrE25.b1, sgp5ebbrE25.a1
Description:
The data was incorrect during the 6 month checks.
Measurements:sgp15ebbrE25.a1:
  • Soil heat flow 1(mv_hft1)
  • Temperature of right humidity sensor chamber(rr_thum_r)
  • Soil heat flow 5(mv_hft5)
  • Left air temperature(tair_l)
  • Soil moisture 4(r_sm4)
  • Soil moisture 3(r_sm3)
  • Net radiation(mv_q)
  • Temperature of left humidity sensor chamber(rr_thum_l)
  • Left relative humidity(mv_hum_l)
  • Soil temperature 1(rr_ts1)
  • Soil heat flow 4(mv_hft4)
  • Soil moisture 1(r_sm1)
  • Reference temperature(rr_tref)
  • Soil moisture 5(r_sm5)
  • Soil temperature 4(rr_ts4)
  • Atmospheric pressure(mv_pres)
  • Right air temperature(tair_r)
  • Right relative humidity(mv_hum_r)
  • Wind direction (relative to true north)(mv_wind_d)
  • Soil temperature 5(rr_ts5)
  • Soil moisture 2(r_sm2)
  • Soil heat flow 3(mv_hft3)
  • Soil temperature 3(rr_ts3)
  • Soil temperature 2(rr_ts2)
  • Soil heat flow 2(mv_hft2)
  • scalar wind speed(wind_s)

sgp30ebbrE25.b1:
  • soil_moisture_2
  • corr_soil_heat_flow_1
  • net_radiation
  • corr_soil_heat_flow_4
  • soil_heat_flow_4
  • soil_temp_5
  • corr_soil_heat_flow_3
  • sensible_heat_flux
  • soil_moisture_1
  • latent_heat_flux
  • wspd_vec_mean
  • wdir_vec_mean
  • soil_moisture_3
  • corr_soil_heat_flow_2
  • soil_moisture_4
  • wdir_vec_std
  • surface_soil_heat_flux_5
  • energy_storage_change_5
  • temp_air_top
  • soil_temp_3
  • vapor_pressure_bottom
  • soil_heat_capacity_5
  • soil_heat_flow_5
  • corr_soil_heat_flow_5
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_4
  • energy_storage_change_3
  • surface_soil_heat_flux_1
  • soil_heat_flow_1
  • surface_soil_heat_flux_3
  • bowen_ratio
  • soil_temp_2
  • vapor_pressure_top
  • surface_soil_heat_flux_4
  • temp_trh_bottom
  • surface_soil_heat_flux_2
  • temp_trh_top
  • temp_air_bottom
  • soil_heat_capacity_1
  • soil_temp_1
  • rh_top_fraction
  • soil_temp_4
  • surface_soil_heat_flux_avg
  • wspd_arith_mean
  • soil_heat_capacity_4
  • soil_heat_flow_2
  • rh_bottom_fraction
  • temp_reference
  • soil_heat_capacity_3
  • Barometric Pressure(atmos_pressure)
  • soil_heat_flow_3
  • soil_heat_capacity_2
  • soil_moisture_5

sgp15ebbrE25.b1:
  • wdir_vec_mean_mv
  • net_radiation_mv
  • temp_air_right
  • soil_temp_4_rr
  • soil_moisture_2_rr
  • soil_moisture_4_rr
  • rh_left_mv
  • soil_moisture_1_rr
  • rh_right_mv
  • soil_heat_flow_5_mv
  • soil_temp_2_rr
  • temp_trh_right_rr
  • soil_temp_1_rr
  • soil_heat_flow_3_mv
  • wspd_arith_mean
  • temp_air_left
  • soil_moisture_3_rr
  • atmos_pressure_mv
  • soil_heat_flow_1_mv
  • temp_reference_rr
  • soil_moisture_5_rr
  • soil_temp_5_rr
  • soil_temp_3_rr
  • temp_trh_left_rr
  • soil_heat_flow_2_mv
  • soil_heat_flow_4_mv

sgp30ebbrE25.a1:
  • bottom vapor pressure(vp_bot)
  • average surface soil heat flow(ave_shf)
  • ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)
  • 5 cm soil heat flow, site 5(shf5)
  • 0-5 cm integrated soil temperature, site 2(ts2)
  • volumetric soil moisture, site 4(sm4)
  • 0-5 cm integrated soil temperature, site 3(ts3)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • volumetric soil moisture, site 1(sm1)
  • 0-5 cm integrated soil temperature, site 5(ts5)
  • scalar wind speed(wind_s)
  • 5 cm soil heat flow, site 4(shf4)
  • 5 cm soil heat flow corrected for soil moisture content, site 4(c_shf4)
  • top vapor pressure(vp_top)
  • volumetric soil moisture, site 3(sm3)
  • Bottom humidity(hum_bot)
  • soil heat flow, site 4(g4)
  • soil heat flow, site 1(g1)
  • 5 cm soil heat flow, site 1(shf1)
  • 0-5 cm change in soil heat storage with time, site 2(ces1)
  • 5 cm soil heat flow, site 2(shf2)
  • 5 cm soil heat flow, site 3(shf3)
  • 0-5 cm change in soil heat storage with time, site 2(ces2)
  • Soil heat capacity 3(cs3)
  • soil heat flow, site 5(g5)
  • 0-5 cm change in soil heat storage with time, site 4(ces4)
  • volumetric soil moisture, site 2(sm2)
  • bottom air temperature(tair_bot)
  • 5 cm soil heat flow corrected for soil moisture content, site 2(c_shf2)
  • Soil heat capacity 4(cs4)
  • standard deviation of wind direction (sigma theta)(sigma_wd)
  • 0-5 cm change in soil heat storage with time, site 3(ces3)
  • vector wind speed(res_ws)
  • 5 cm soil heat flow corrected for soil moisture content, site 3(c_shf3)
  • wind direction (relative to true north)(wind_d)
  • Temperature of the top humidity chamber(thum_top)
  • h(h)
  • 0-5 cm change in soil heat storage with time, site 5(ces5)
  • 5 cm soil heat flow corrected for soil moisture content, site 1(c_shf1)
  • top air temperature(tair_top)
  • Retrieved pressure profile(pres)
  • 5 cm soil heat flow corrected for soil moisture content, site 5(c_shf5)
  • Reference Thermistor Temperature(tref)
  • Soil heat capacity 2(cs2)
  • Top humidity(hum_top)
  • soil heat flow, site 2(g2)
  • net radiation(q)
  • soil heat flow, site 3(g3)
  • Soil heat capacity 1(cs1)
  • latent heat flux(e)
  • volumetric soil moisture, site 5(sm5)
  • Soil heat capacity 5(cs5)
  • 0-5 cm integrated soil temperature, site 2(ts1)
  • 0-5 cm integrated soil temperature, site 4(ts4)

sgp5ebbrE25.a1:
  • bottom vapor pressure(vp_bot)
  • vector wind speed(res_ws)
  • Retrieved pressure profile(pres)
  • Bottom humidity(hum_bot)
  • wind direction (relative to true north)(wind_d)
  • Top humidity(hum_top)
  • standard deviation of wind direction (sigma theta)(sigma_wd)
  • bottom air temperature(tair_bot)
  • net radiation(q)
  • top air temperature(tair_top)
  • top vapor pressure(vp_top)
  • scalar wind speed(wind_s)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • Reference Thermistor Temperature(tref)
  • Temperature of the top humidity chamber(thum_top)


Back To Table of Contents

DQRID : D011206.8
Start DateStart TimeEnd DateEnd Time
04/18/2001164504/18/20011701
Subject:
SGP EBBR E25 - E25 EBBR Soil Heat Flow #3 Incorrect
DataStreams:sgp15ebbrE25.a1, sgp15ebbrE25.b1, sgp30ebbrE25.a1, sgp30ebbrE25.b1
Description:
Soil heat flow #3 was large negative during the indicated period.
Measurements:sgp15ebbrE25.a1:
  • Soil heat flow 3(mv_hft3)

sgp30ebbrE25.b1:
  • surface_soil_heat_flux_avg
  • surface_soil_heat_flux_3
  • soil_heat_flow_3
  • corr_soil_heat_flow_3
  • sensible_heat_flux
  • latent_heat_flux

sgp15ebbrE25.b1:
  • soil_heat_flow_3_mv

sgp30ebbrE25.a1:
  • latent heat flux(e)
  • average surface soil heat flow(ave_shf)
  • h(h)
  • soil heat flow, site 3(g3)
  • 5 cm soil heat flow, site 3(shf3)
  • 5 cm soil heat flow corrected for soil moisture content, site 3(c_shf3)


Back To Table of Contents

DQRID : D011206.9
Start DateStart TimeEnd DateEnd Time
05/13/2001003005/16/20011931
Subject:
SGP EBBR E25 - E25 EBBR Soil Heat Flow #1 Incorrect
DataStreams:sgp15ebbrE25.a1, sgp15ebbrE25.b1, sgp30ebbrE25.a1, sgp30ebbrE25.b1
Description:
Soil heat flow #1 was large negative or large positive during the
indicated period.
Measurements:sgp15ebbrE25.a1:
  • Soil heat flow 1(mv_hft1)

sgp30ebbrE25.b1:
  • soil_heat_flow_1
  • surface_soil_heat_flux_avg
  • corr_soil_heat_flow_1
  • sensible_heat_flux
  • latent_heat_flux
  • surface_soil_heat_flux_1

sgp15ebbrE25.b1:
  • soil_heat_flow_1_mv

sgp30ebbrE25.a1:
  • latent heat flux(e)
  • average surface soil heat flow(ave_shf)
  • h(h)
  • 5 cm soil heat flow corrected for soil moisture content, site 1(c_shf1)
  • soil heat flow, site 1(g1)
  • 5 cm soil heat flow, site 1(shf1)


Back To Table of Contents

DQRID : D030709.1
Start DateStart TimeEnd DateEnd Time
04/01/2001000004/08/20022359
Subject:
SGP/EBBR/E25 - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR 
Header
DataStreams:sgp30ebbrE25.b1
Description:
The units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in the 
EBBR 30 minute netcdf header have been incorrect from the beginning 
of processing the data into netcdf files.  The correct units are 
MJ/m^3/C.

This does not affect the data quality.
Measurements:sgp30ebbrE25.b1:
  • soil_heat_capacity_3
  • soil_heat_capacity_1
  • soil_heat_capacity_5
  • soil_heat_capacity_2
  • soil_heat_capacity_4


Back To Table of Contents

DQRID : D051115.10
Start DateStart TimeEnd DateEnd Time
04/01/2001000004/08/20022359
Subject:
SGP/EBBR/E25 - metadata errors
DataStreams:sgp15ebbrE25.b1, sgp30ebbrE25.b1
Description:
During the entire span of EBBR.E25 data, the cdf data files contained a few minor global 
metadata errors. These errors do not affect the data values or quality.

The errors include:
* incomplete sensor location information
* incomplete installation date information
* soil moisture documented as "by volume" should have read "gravimetric"
Measurements:sgp30ebbrE25.b1:
  • base time(base_time)

sgp15ebbrE25.b1:
  • base time(base_time)


Back To Table of Contents



END OF DATA