Data Quality Reports for Session: 119177 User: dmfoper Completed: 04/28/2009


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D051215.3SGP/EBBR/E15 - Net Radiation, Sensible and Latent Heat Fluxes Incorrect.sgp15ebbrE15.b1, sgp30ebbrE15.b1, sgp5ebbrE15.b1
D060111.10SGP/EBBR/E15 - Incorrect Sensible and Latent Heat Fluxessgp15ebbrE15.b1, sgp30ebbrE15.b1, sgp5ebbrE15.b1
D060501.15SGP/EBBR/E15 - Wind Speed Sensor Frozen Stoppedsgp15ebbrE15.b1, sgp30ebbrE15.b1, sgp5ebbrE15.b1
D080616.4SGP/EBBR/E15 - Water in domesgp15ebbrE15.b1, sgp30ebbrE15.b1, sgp5ebbrE15.b1


DQRID : D051215.3
Start DateStart TimeEnd DateEnd Time
10/30/2005000011/08/20051815
Subject:
SGP/EBBR/E15 - Net Radiation, Sensible and Latent Heat Fluxes Incorrect.
DataStreams:sgp15ebbrE15.b1, sgp30ebbrE15.b1, sgp5ebbrE15.b1
Description:
The top dome of the net radiometer was broken, resulting in net radiations that were too 
small, and thus sensible and latent heat fluxes that were too small.
Measurements:sgp15ebbrE15.b1:
  • net_radiation_mv

sgp30ebbrE15.b1:
  • latent_heat_flux
  • sensible_heat_flux
  • net_radiation

sgp5ebbrE15.b1:
  • net_radiation


Back To Table of Contents

DQRID : D060111.10
Start DateStart TimeEnd DateEnd Time
01/10/2006133001/17/20061730
Subject:
SGP/EBBR/E15 - Incorrect Sensible and Latent Heat Fluxes
DataStreams:sgp15ebbrE15.b1, sgp30ebbrE15.b1, sgp5ebbrE15.b1
Description:
Incorrect gradient measurements and sensible and latent heat fluxes resulted from the AEM 
not exchanging.
Measurements:sgp15ebbrE15.b1:
  • temp_air_left
  • temp_air_right

sgp30ebbrE15.b1:
  • vapor_pressure_top
  • temp_air_top
  • vapor_pressure_bottom
  • bowen_ratio
  • rh_top_fraction
  • latent_heat_flux
  • temp_trh_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • temp_air_bottom
  • sensible_heat_flux

sgp5ebbrE15.b1:
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_top
  • temp_air_bottom
  • temp_trh_bottom
  • vapor_pressure_bottom
  • rh_bottom_fraction
  • rh_top_fraction


Back To Table of Contents

DQRID : D060501.15
Start DateStart TimeEnd DateEnd Time
02/22/2006130002/22/20061530
Subject:
SGP/EBBR/E15 - Wind Speed Sensor Frozen Stopped
DataStreams:sgp15ebbrE15.b1, sgp30ebbrE15.b1, sgp5ebbrE15.b1
Description:
Freezing rain froze the wind speed sensor to a stopped condition during the period.
Measurements:sgp15ebbrE15.b1:
  • wspd_arith_mean

sgp30ebbrE15.b1:
  • wspd_vec_mean
  • wspd_arith_mean

sgp5ebbrE15.b1:
  • wspd_arith_mean
  • wspd_vec_mean


Back To Table of Contents

DQRID : D080616.4
Start DateStart TimeEnd DateEnd Time
06/11/2008150006/20/20081500
Subject:
SGP/EBBR/E15 - Water in dome
DataStreams:sgp15ebbrE15.b1, sgp30ebbrE15.b1, sgp5ebbrE15.b1
Description:
There was water in the bottom dome of the net radiometer.

Net radiation, and sensible and latent heat fluxes were 
incorrect during the period.
Measurements:sgp15ebbrE15.b1:
  • net_radiation_mv

sgp30ebbrE15.b1:
  • latent_heat_flux
  • sensible_heat_flux
  • net_radiation

sgp5ebbrE15.b1:
  • net_radiation


Back To Table of Contents