DQR ID | Subject | Data Streams Affected |
---|---|---|
D050206.7 | SGP/EBBR/E8 - Wind Speed Frozen Stopped By Ice Storm | sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1 |
D050207.3 | SGP/EBBR/E8 - Wind Direction Frozen Stopped By Ice Storm | sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1 |
D050215.12 | SGP/EBBR/E8 - Wind Speed Frozen Stopped By Ice Storm | sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1 |
D050215.13 | SGP/EBBR/E8 - Wind Direction Frozen Stopped By Ice | sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1 |
D050413.3 | SGP/EBBR/E8 - Battery Voltage Problem | sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1 |
D051106.5 | SGP/EBBR/E8 - Net Radiation Incorrect; Sensible and Latent Heat Fluxes Incorrect | sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1 |
D051112.5 | SGP/EBBR/E8 - metadata corrections | sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1 |
D060111.4 | SGP/EBBR/E8 - AEM Not Exchanging | sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1 |
D060501.6 | SGP/EBBR/E8 - Flux and Gradient Measurements Suspect | sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1 |
D060501.8 | SGP/EBBR/E8 - Wind Speed Sensor Frozen Stopped | sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1 |
D060501.9 | SGP/EBBR/E8 - Fluxes Incorrect; Left Humidity Near Zero | sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1 |
D060508.2 | SGP/EBBR/E8 - Sensible and Latent Heat Flux Suspect | sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1 |
D060818.8 | SGP/EBBR/E8 - Sensible and Latent Heat Fluxes and Net Radiation Incorrect | sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1 |
D070223.2 | SGP/EBBR/E8 - Failed Temp/RH sensor | sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/03/2005 | 0810 | 01/04/2005 | 2100 |
Subject: | SGP/EBBR/E8 - Wind Speed Frozen Stopped By Ice Storm |
DataStreams: | sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1 |
Description: | An ice storm froze the wind speed sensor to a stopped condition. The wind speed and residual wind speed measurements are incorrect. This sensor failure does not affect the sensible and latent heat fluxes. |
Measurements: | sgp30ebbrE8.b1:
sgp5ebbrE8.b1:
sgp15ebbrE8.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/03/2005 | 0850 | 01/04/2005 | 2100 |
Subject: | SGP/EBBR/E8 - Wind Direction Frozen Stopped By Ice Storm |
DataStreams: | sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1 |
Description: | The wind direction sensor was frozen stopped by ice from a storm. The wind direction, sigma_wd, and residual wind speed measurements are incorrect. |
Measurements: | sgp30ebbrE8.b1:
sgp5ebbrE8.b1:
sgp15ebbrE8.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/12/2005 | 0720 | 01/12/2005 | 1605 |
02/07/2005 | 0200 | 02/08/2005 | 1930 |
Subject: | SGP/EBBR/E8 - Wind Speed Frozen Stopped By Ice Storm |
DataStreams: | sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1 |
Description: | An ice storm froze the wind speed sensor to a stopped condition. The wind speed and residual wind speed measurements are incorrect. This sensor failure does not affect the sensible and latent heat fluxes. |
Measurements: | sgp30ebbrE8.b1:
sgp5ebbrE8.b1:
sgp15ebbrE8.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/07/2005 | 0500 | 02/08/2005 | 0330 |
Subject: | SGP/EBBR/E8 - Wind Direction Frozen Stopped By Ice |
DataStreams: | sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1 |
Description: | The wind direction sensor was frozen stopped by ice from a storm. The wind direction, sigma_wd, and residual wind speed measurements are incorrect. |
Measurements: | sgp30ebbrE8.b1:
sgp5ebbrE8.b1:
sgp15ebbrE8.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/21/2005 | 0230 | 04/26/2005 | 2215 |
Subject: | SGP/EBBR/E8 - Battery Voltage Problem |
DataStreams: | sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1 |
Description: | Battery voltage was too low to give correct data. |
Measurements: | sgp30ebbrE8.b1:
sgp5ebbrE8.b1:
sgp15ebbrE8.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/04/2005 | 2000 | 08/09/2005 | 2030 |
Subject: | SGP/EBBR/E8 - Net Radiation Incorrect; Sensible and Latent Heat Fluxes Incorrect |
DataStreams: | sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1 |
Description: | The top dome of the net radiometer was cracked and water had gotten inside it, so net radiation, and sensible and latent heat fluxes were incorrect. |
Measurements: | sgp30ebbrE8.b1:
sgp5ebbrE8.b1:
sgp15ebbrE8.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/13/2003 | 0000 | 07/22/2005 | 2359 |
Subject: | SGP/EBBR/E8 - metadata corrections |
DataStreams: | sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1 |
Description: | On 20050723, a series of metadata corrections and additions were completed. These metadata changes apply to all EBBR.E8 data collected by ARM back to the installation of the instrument in December 1992. Please see the current metadata for correct information. These changes do not affect data values or quality. The changes are summarized below: 1) Update of "sensor location" information 2) Addition of installation dates for the systems 3) Correction of soil moisture units (from "by volume" to "gravimetric") |
Measurements: | sgp30ebbrE8.b1:
sgp5ebbrE8.b1:
sgp15ebbrE8.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/26/2005 | 1900 | 01/10/2006 | 1630 |
Subject: | SGP/EBBR/E8 - AEM Not Exchanging |
DataStreams: | sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1 |
Description: | The AEM hung in one position frequently and sometimes for many days during this period While the AEM was not switching, the sensible and latent heat fluxes and gradient measurements were incorrect. |
Measurements: | sgp30ebbrE8.b1:
sgp5ebbrE8.b1:
sgp15ebbrE8.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/07/2005 | 0000 | 01/24/2006 | 2330 |
Subject: | SGP/EBBR/E8 - Flux and Gradient Measurements Suspect |
DataStreams: | sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1 |
Description: | The flux and gradient measurements were often incorrect when the AEM did not function properly. The user needs to inspect the data (particularly the home signals) to determine when the AEM was and was not working. |
Measurements: | sgp30ebbrE8.b1:
sgp5ebbrE8.b1:
sgp15ebbrE8.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/21/2006 | 0230 | 03/21/2006 | 1600 |
Subject: | SGP/EBBR/E8 - Wind Speed Sensor Frozen Stopped |
DataStreams: | sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1 |
Description: | Freezing rain froze the wind speed sensor to a stopped condition. |
Measurements: | sgp30ebbrE8.b1:
sgp5ebbrE8.b1:
sgp15ebbrE8.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/22/2006 | 2030 | 04/04/2006 | 1500 |
Subject: | SGP/EBBR/E8 - Fluxes Incorrect; Left Humidity Near Zero |
DataStreams: | sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1 |
Description: | The left humidity was intermittently incorrect, therefore the sensible and latent heat fluxes were also. |
Measurements: | sgp30ebbrE8.b1:
sgp5ebbrE8.b1:
sgp15ebbrE8.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/22/2006 | 1030 | 05/31/2006 | 0030 |
Subject: | SGP/EBBR/E8 - Sensible and Latent Heat Flux Suspect |
DataStreams: | sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1 |
Description: | The left humidity sensor produced large spikes frequently. This resulted in incorrect measurements of vapor pressure gradient and thus calculations of sensible and latent heat flux. |
Measurements: | sgp30ebbrE8.b1:
sgp5ebbrE8.b1:
sgp15ebbrE8.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/23/2006 | 0130 | 06/27/2006 | 1730 |
Subject: | SGP/EBBR/E8 - Sensible and Latent Heat Fluxes and Net Radiation Incorrect |
DataStreams: | sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1 |
Description: | The net radiometer top dome was broken and water had gotten into it. Sensible and latent heat fluxes and net radiation were therefore incorrect. |
Measurements: | sgp30ebbrE8.b1:
sgp5ebbrE8.b1:
sgp15ebbrE8.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/22/2007 | 1630 | 03/06/2007 | 2100 |
Subject: | SGP/EBBR/E8 - Failed Temp/RH sensor |
DataStreams: | sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1 |
Description: | The right Temperature-Humidity sensor failed. The measured temperature gradients were incorrect and thus the sensible and latent heat fluxes were incorrect for this extended period. The sensor was replaced March 6. |
Measurements: | sgp30ebbrE8.b1:
sgp5ebbrE8.b1:
sgp15ebbrE8.b1:
|