Data Quality Reports for Session: 119005 User: dmfoper Completed: 04/18/2009


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D050206.7SGP/EBBR/E8 - Wind Speed Frozen Stopped By Ice Stormsgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
D050207.3SGP/EBBR/E8 - Wind Direction Frozen Stopped By Ice Stormsgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
D050215.12SGP/EBBR/E8 - Wind Speed Frozen Stopped By Ice Stormsgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
D050215.13SGP/EBBR/E8 - Wind Direction Frozen Stopped By Icesgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
D050413.3SGP/EBBR/E8 - Battery Voltage Problemsgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
D051106.5SGP/EBBR/E8 - Net Radiation Incorrect; Sensible and Latent Heat Fluxes Incorrectsgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
D051112.5SGP/EBBR/E8 - metadata correctionssgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
D060111.4SGP/EBBR/E8 - AEM Not Exchangingsgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
D060501.6SGP/EBBR/E8 - Flux and Gradient Measurements Suspectsgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
D060501.8SGP/EBBR/E8 - Wind Speed Sensor Frozen Stoppedsgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
D060501.9SGP/EBBR/E8 - Fluxes Incorrect; Left Humidity Near Zerosgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
D060508.2SGP/EBBR/E8 - Sensible and Latent Heat Flux Suspectsgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
D060818.8SGP/EBBR/E8 - Sensible and Latent Heat Fluxes and Net Radiation Incorrectsgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
D070223.2SGP/EBBR/E8 - Failed Temp/RH sensorsgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1


DQRID : D050206.7
Start DateStart TimeEnd DateEnd Time
01/03/2005081001/04/20052100
Subject:
SGP/EBBR/E8  - Wind Speed Frozen Stopped By Ice Storm
DataStreams:sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp30ebbrE8.b1:
  • wspd_vec_mean
  • wspd_arith_mean

sgp5ebbrE8.b1:
  • wspd_arith_mean
  • wspd_vec_mean

sgp15ebbrE8.b1:
  • wspd_arith_mean


Back To Table of Contents

DQRID : D050207.3
Start DateStart TimeEnd DateEnd Time
01/03/2005085001/04/20052100
Subject:
SGP/EBBR/E8  - Wind Direction Frozen Stopped By Ice Storm
DataStreams:sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
Description:
The wind direction sensor was frozen stopped by ice from a storm.  
The wind direction, sigma_wd, and residual wind speed measurements 
are incorrect.
Measurements:sgp30ebbrE8.b1:
  • wspd_vec_mean
  • wdir_vec_std
  • wdir_vec_mean

sgp5ebbrE8.b1:
  • wdir_vec_std
  • wdir_vec_mean
  • wspd_vec_mean

sgp15ebbrE8.b1:
  • wdir_vec_mean_mv


Back To Table of Contents

DQRID : D050215.12
Start DateStart TimeEnd DateEnd Time
01/12/2005072001/12/20051605
02/07/2005020002/08/20051930
Subject:
SGP/EBBR/E8  - Wind Speed Frozen Stopped By Ice Storm
DataStreams:sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp30ebbrE8.b1:
  • wspd_vec_mean
  • wspd_arith_mean

sgp5ebbrE8.b1:
  • wspd_arith_mean
  • wspd_vec_mean

sgp15ebbrE8.b1:
  • wspd_arith_mean


Back To Table of Contents

DQRID : D050215.13
Start DateStart TimeEnd DateEnd Time
02/07/2005050002/08/20050330
Subject:
SGP/EBBR/E8  - Wind Direction Frozen Stopped By Ice
DataStreams:sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
Description:
The wind direction sensor was frozen stopped by ice from a storm.  
The wind direction, sigma_wd, and residual wind speed measurements 
are incorrect.
Measurements:sgp30ebbrE8.b1:
  • wspd_vec_mean
  • wdir_vec_std
  • wdir_vec_mean

sgp5ebbrE8.b1:
  • wdir_vec_std
  • wdir_vec_mean
  • wspd_vec_mean

sgp15ebbrE8.b1:
  • wdir_vec_mean_mv


Back To Table of Contents

DQRID : D050413.3
Start DateStart TimeEnd DateEnd Time
04/21/2005023004/26/20052215
Subject:
SGP/EBBR/E8 - Battery Voltage Problem
DataStreams:sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
Description:
Battery voltage was too low to give correct data.
Measurements:sgp30ebbrE8.b1:
  • wspd_vec_mean
  • bowen_ratio
  • surface_soil_heat_flux_5
  • latent_heat_flux
  • energy_storage_change_1
  • soil_heat_flow_5
  • surface_soil_heat_flux_2
  • temp_trh_top
  • soil_heat_flow_4
  • surface_soil_heat_flux_1
  • lon(lon)
  • soil_heat_flow_3
  • surface_soil_heat_flux_4
  • wdir_vec_std
  • soil_heat_flow_1
  • energy_storage_change_5
  • rh_top_fraction
  • energy_storage_change_3
  • lat(lat)
  • soil_temp_3
  • energy_storage_change_4
  • net_radiation
  • soil_moisture_4
  • surface_soil_heat_flux_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5
  • soil_heat_flow_2
  • surface_soil_heat_flux_avg
  • home_signal_15
  • wspd_arith_mean
  • base time(base_time)
  • soil_moisture_5
  • vapor_pressure_bottom
  • soil_temp_1
  • home_signal_30
  • energy_storage_change_2
  • corr_soil_heat_flow_2
  • soil_temp_5
  • wdir_vec_mean
  • soil_moisture_3
  • soil_moisture_2
  • soil_temp_4
  • temp_air_top
  • vapor_pressure_top
  • soil_temp_2
  • soil_heat_capacity_2
  • corr_soil_heat_flow_1
  • soil_heat_capacity_1
  • temp_trh_bottom
  • rh_bottom_fraction
  • temp_reference
  • temp_air_bottom
  • soil_heat_capacity_3
  • Dummy altitude for Zeb(alt)
  • corr_soil_heat_flow_3
  • soil_moisture_1
  • Time offset of tweaks from base_time(time_offset)
  • soil_heat_capacity_5
  • sensible_heat_flux
  • soil_heat_capacity_4
  • Barometric Pressure(atmos_pressure)

sgp5ebbrE8.b1:
  • Time offset of tweaks from base_time(time_offset)
  • vapor_pressure_bottom
  • base time(base_time)
  • temp_trh_top
  • rh_top_fraction
  • Barometric Pressure(atmos_pressure)
  • net_radiation
  • time(time)
  • temp_air_bottom
  • lat(lat)
  • temp_reference
  • temp_air_top
  • temp_trh_bottom
  • wspd_vec_mean
  • wdir_vec_std
  • wdir_vec_mean
  • home_signal
  • rh_bottom_fraction
  • vapor_pressure_top
  • lon(lon)
  • wspd_arith_mean
  • Dummy altitude for Zeb(alt)

sgp15ebbrE8.b1:
  • soil_heat_flow_1_mv
  • wdir_vec_mean_mv
  • temp_reference_rr
  • base time(base_time)
  • Dummy altitude for Zeb(alt)
  • soil_moisture_1_rr
  • soil_heat_flow_2_mv
  • soil_moisture_5_rr
  • Time offset of tweaks from base_time(time_offset)
  • battery_voltage
  • temp_air_left
  • soil_heat_flow_3_mv
  • wspd_arith_mean
  • rh_left_mv
  • soil_moisture_4_rr
  • temp_trh_right_rr
  • home_signal
  • soil_temp_3_rr
  • soil_temp_5_rr
  • lat(lat)
  • soil_temp_4_rr
  • atmos_pressure_mv
  • temp_trh_left_rr
  • temp_air_right
  • soil_temp_1_rr
  • soil_heat_flow_4_mv
  • soil_heat_flow_5_mv
  • soil_moisture_2_rr
  • rh_right_mv
  • lon(lon)
  • net_radiation_mv
  • soil_temp_2_rr
  • soil_moisture_3_rr


Back To Table of Contents

DQRID : D051106.5
Start DateStart TimeEnd DateEnd Time
08/04/2005200008/09/20052030
Subject:
SGP/EBBR/E8 - Net Radiation Incorrect; Sensible and Latent Heat Fluxes Incorrect
DataStreams:sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
Description:
The top dome of the net radiometer was cracked and water had gotten inside it, so net 
radiation, and sensible and latent heat fluxes were incorrect.
Measurements:sgp30ebbrE8.b1:
  • sensible_heat_flux
  • net_radiation
  • latent_heat_flux

sgp5ebbrE8.b1:
  • net_radiation

sgp15ebbrE8.b1:
  • net_radiation_mv


Back To Table of Contents

DQRID : D051112.5
Start DateStart TimeEnd DateEnd Time
10/13/2003000007/22/20052359
Subject:
SGP/EBBR/E8 - metadata corrections
DataStreams:sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
Description:
On 20050723, a series of metadata corrections and additions were completed.  These 
metadata changes apply to all EBBR.E8 data collected by ARM back to the installation of the 
instrument in December 1992. Please see the current metadata for correct information.  These 
changes do not affect data values or quality.	

The changes are summarized below:
1) Update of "sensor location" information
2) Addition of installation dates for the systems
3) Correction of soil moisture units (from "by volume" to "gravimetric")
Measurements:sgp30ebbrE8.b1:
  • base time(base_time)

sgp5ebbrE8.b1:
  • base time(base_time)

sgp15ebbrE8.b1:
  • base time(base_time)


Back To Table of Contents

DQRID : D060111.4
Start DateStart TimeEnd DateEnd Time
11/26/2005190001/10/20061630
Subject:
SGP/EBBR/E8 - AEM Not Exchanging
DataStreams:sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
Description:
The AEM hung in one position frequently and sometimes for many days during this period

While the AEM was not switching, the sensible and latent heat fluxes and gradient 
measurements were incorrect.
Measurements:sgp30ebbrE8.b1:
  • sensible_heat_flux
  • temp_trh_top
  • bowen_ratio
  • vapor_pressure_top
  • temp_air_bottom
  • latent_heat_flux
  • vapor_pressure_bottom
  • temp_air_top
  • rh_top_fraction
  • rh_bottom_fraction
  • temp_trh_bottom

sgp5ebbrE8.b1:
  • temp_air_top
  • vapor_pressure_bottom
  • rh_bottom_fraction
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • temp_air_bottom
  • rh_top_fraction

sgp15ebbrE8.b1:
  • temp_air_right
  • temp_air_left


Back To Table of Contents

DQRID : D060501.6
Start DateStart TimeEnd DateEnd Time
12/07/2005000001/24/20062330
Subject:
SGP/EBBR/E8 - Flux and Gradient Measurements Suspect
DataStreams:sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
Description:
The flux and gradient measurements were often incorrect when the AEM did not function 
properly.  The user needs to inspect the data (particularly the home signals) to determine 
when the AEM was and was not working.
Measurements:sgp30ebbrE8.b1:
  • bowen_ratio
  • temp_air_bottom
  • latent_heat_flux
  • temp_air_top
  • sensible_heat_flux
  • temp_trh_top
  • vapor_pressure_top
  • vapor_pressure_bottom
  • rh_top_fraction
  • temp_trh_bottom
  • rh_bottom_fraction

sgp5ebbrE8.b1:
  • rh_bottom_fraction
  • vapor_pressure_top
  • temp_air_bottom
  • temp_air_top
  • vapor_pressure_bottom
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction

sgp15ebbrE8.b1:
  • temp_air_right
  • temp_air_left
  • rh_right_mv
  • rh_left_mv
  • temp_trh_right_rr
  • temp_trh_left_rr


Back To Table of Contents

DQRID : D060501.8
Start DateStart TimeEnd DateEnd Time
03/21/2006023003/21/20061600
Subject:
SGP/EBBR/E8 - Wind Speed Sensor Frozen Stopped
DataStreams:sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
Description:
Freezing rain froze the wind speed sensor to a stopped condition.
Measurements:sgp30ebbrE8.b1:
  • wspd_vec_mean
  • wspd_arith_mean

sgp5ebbrE8.b1:
  • wspd_arith_mean
  • wspd_vec_mean

sgp15ebbrE8.b1:
  • wspd_arith_mean


Back To Table of Contents

DQRID : D060501.9
Start DateStart TimeEnd DateEnd Time
02/22/2006203004/04/20061500
Subject:
SGP/EBBR/E8 - Fluxes Incorrect; Left Humidity Near Zero
DataStreams:sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
Description:
The left humidity was intermittently incorrect, therefore the sensible and latent heat 
fluxes were also.
Measurements:sgp30ebbrE8.b1:
  • sensible_heat_flux
  • vapor_pressure_bottom
  • bowen_ratio
  • vapor_pressure_top
  • rh_top_fraction
  • rh_bottom_fraction
  • latent_heat_flux

sgp5ebbrE8.b1:
  • vapor_pressure_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top

sgp15ebbrE8.b1:
  • rh_left_mv


Back To Table of Contents

DQRID : D060508.2
Start DateStart TimeEnd DateEnd Time
04/22/2006103005/31/20060030
Subject:
SGP/EBBR/E8 - Sensible and Latent Heat Flux Suspect
DataStreams:sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
Description:
The left humidity sensor produced large spikes frequently.  This resulted in incorrect 
measurements of vapor pressure gradient and thus calculations of sensible and latent heat 
flux.
Measurements:sgp30ebbrE8.b1:
  • sensible_heat_flux
  • vapor_pressure_bottom
  • bowen_ratio
  • vapor_pressure_top
  • rh_top_fraction
  • rh_bottom_fraction
  • latent_heat_flux

sgp5ebbrE8.b1:
  • vapor_pressure_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top

sgp15ebbrE8.b1:
  • rh_left_mv


Back To Table of Contents

DQRID : D060818.8
Start DateStart TimeEnd DateEnd Time
06/23/2006013006/27/20061730
Subject:
SGP/EBBR/E8 - Sensible and Latent Heat Fluxes and Net Radiation Incorrect
DataStreams:sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
Description:
The net radiometer top dome was broken and water had gotten into it.

Sensible and latent heat fluxes and net radiation were therefore incorrect.
Measurements:sgp30ebbrE8.b1:
  • sensible_heat_flux
  • net_radiation
  • latent_heat_flux

sgp5ebbrE8.b1:
  • net_radiation

sgp15ebbrE8.b1:
  • net_radiation_mv


Back To Table of Contents

DQRID : D070223.2
Start DateStart TimeEnd DateEnd Time
02/22/2007163003/06/20072100
Subject:
SGP/EBBR/E8 - Failed Temp/RH sensor
DataStreams:sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
Description:
The right Temperature-Humidity sensor failed. The measured temperature gradients were 
incorrect and thus the sensible and latent heat fluxes were incorrect for this extended 
period.

The sensor was replaced March 6.
Measurements:sgp30ebbrE8.b1:
  • sensible_heat_flux
  • temp_trh_top
  • vapor_pressure_bottom
  • bowen_ratio
  • vapor_pressure_top
  • temp_trh_bottom
  • latent_heat_flux

sgp5ebbrE8.b1:
  • vapor_pressure_bottom
  • temp_trh_top
  • vapor_pressure_top
  • temp_trh_bottom

sgp15ebbrE8.b1:
  • temp_trh_right_rr


Back To Table of Contents



END OF DATA