Data Quality Reports for Session: 119004 User: dmfoper Completed: 04/18/2009


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D031222.12SGP/EBBR/E8 - Net Radiometer Iced Over During Stormsgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
D040304.6SGP/EBBR/E8 - Wind Speed Frozen Stopped By Icesgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
D040304.7SGP/EBBR/E8 - Wind Direction Frozen Stopped By Icesgp30ebbrE8.b1, sgp5ebbrE8.b1
D040318.17SGP/EBBR/E8 - Wind Speed Sensor Frozen Stopped By Icingsgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
D040331.2SGP/EBBR/E8 - AEM Replacementsgp15ebbrE8.b1, sgp30baebbrE8.c1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
D040915.5SGP/EBBR/E8 - Net Radiation Incorrect, Fluxes Incorrectsgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
D041222.9SGP/EBBR/E8 - 6 Month Checkssgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
D051112.5SGP/EBBR/E8 - metadata correctionssgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1


DQRID : D031222.12
Start DateStart TimeEnd DateEnd Time
12/13/2003140012/14/20032200
Subject:
SGP/EBBR/E8  - Net Radiometer Iced Over During Storm
DataStreams:sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
Description:
The net radiometer was covered with ice from a storm.  Net radiation values are incorrect, 
and are sometimes even negative during the daytime.  Sensible and latent heat fluxes are 
therefore incorrect.
Measurements:sgp30ebbrE8.b1:
  • sensible_heat_flux
  • net_radiation
  • latent_heat_flux

sgp5ebbrE8.b1:
  • net_radiation

sgp15ebbrE8.b1:
  • net_radiation_mv


Back To Table of Contents

DQRID : D040304.6
Start DateStart TimeEnd DateEnd Time
01/31/2004191002/04/20041750
02/05/2004102002/06/20040820
Subject:
SGP/EBBR/E8  - Wind Speed Frozen Stopped By Ice
DataStreams:sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp30ebbrE8.b1:
  • wspd_vec_mean
  • wspd_arith_mean

sgp5ebbrE8.b1:
  • wspd_arith_mean
  • wspd_vec_mean

sgp15ebbrE8.b1:
  • wspd_arith_mean


Back To Table of Contents

DQRID : D040304.7
Start DateStart TimeEnd DateEnd Time
01/25/2004230001/26/20042135
01/27/2004042501/27/20040630
01/27/2004113001/27/20041740
Subject:
SGP/EBBR/E8  - Wind Direction Frozen Stopped By Ice
DataStreams:sgp30ebbrE8.b1, sgp5ebbrE8.b1
Description:
The wind direction sensor was frozen stopped by ice from a storm.  
The wind direction, sigma_wd, and residual wind speed measurements 
are incorrect.
Measurements:sgp30ebbrE8.b1:
  • wspd_vec_mean
  • wdir_vec_std
  • wdir_vec_mean

sgp5ebbrE8.b1:
  • wdir_vec_std
  • wdir_vec_mean
  • wspd_vec_mean


Back To Table of Contents

DQRID : D040318.17
Start DateStart TimeEnd DateEnd Time
02/26/2004071002/26/20041410
Subject:
SGP/EBBR/E8  - Wind Speed Sensor Frozen Stopped By Icing
DataStreams:sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp30ebbrE8.b1:
  • wspd_vec_mean
  • wspd_arith_mean

sgp5ebbrE8.b1:
  • wspd_arith_mean
  • wspd_vec_mean

sgp15ebbrE8.b1:
  • wspd_arith_mean


Back To Table of Contents

DQRID : D040331.2
Start DateStart TimeEnd DateEnd Time
04/05/2004000004/06/20041755
Subject:
SGP/EBBR/E8 - AEM Replacement
DataStreams:sgp15ebbrE8.b1, sgp30baebbrE8.c1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
Description:
The AEM at E8 kept hanging in between home positions.

This DQR covers only the period during which the AEM was being
replaced.  

DQRs generally are not issued for AEMs that are not working
as qc flags indicate this clearly.
Measurements:sgp30ebbrE8.b1:
  • bowen_ratio
  • temp_air_bottom
  • latent_heat_flux
  • temp_air_top
  • sensible_heat_flux
  • temp_trh_top
  • vapor_pressure_top
  • vapor_pressure_bottom
  • rh_top_fraction
  • rh_bottom_fraction
  • temp_trh_bottom

sgp5ebbrE8.b1:
  • rh_bottom_fraction
  • vapor_pressure_top
  • temp_air_bottom
  • temp_air_top
  • vapor_pressure_bottom
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction

sgp30baebbrE8.c1:
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • Aerodynamic Latent heat flux(ale)
  • Best estimate Sensible heat flux(hcomb)
  • latent heat flux(e)
  • ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)
  • Bottom humidity(hum_bot)
  • top air temperature(tair_top)
  • Aerodynamic Sensible heat flux(ah)
  • Temperature of the top humidity chamber(thum_top)
  • Best estimate Latent heat flux(ecomb)
  • Top humidity(hum_top)
  • bottom air temperature(tair_bot)
  • h(h)
  • bottom vapor pressure(vp_bot)
  • top vapor pressure(vp_top)

sgp15ebbrE8.b1:
  • temp_air_right
  • temp_air_left


Back To Table of Contents

DQRID : D040915.5
Start DateStart TimeEnd DateEnd Time
08/30/2004120009/07/20041730
Subject:
SGP/EBBR/E8 - Net Radiation Incorrect, Fluxes Incorrect
DataStreams:sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
Description:
The net radiometer dome was broken and water entered the botom dome,
causing net radiation measurements, and thus sensible and latent heat 
flux measurements, to be incorrect.
Measurements:sgp30ebbrE8.b1:
  • sensible_heat_flux
  • net_radiation
  • latent_heat_flux

sgp5ebbrE8.b1:
  • net_radiation

sgp15ebbrE8.b1:
  • net_radiation_mv


Back To Table of Contents

DQRID : D041222.9
Start DateStart TimeEnd DateEnd Time
10/19/2004173010/19/20041800
Subject:
SGP/EBBR/E8 - 6 Month Checks
DataStreams:sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp30ebbrE8.b1:
  • bowen_ratio
  • temp_air_bottom
  • latent_heat_flux
  • temp_air_top
  • sensible_heat_flux
  • temp_trh_top
  • vapor_pressure_top
  • vapor_pressure_bottom
  • rh_top_fraction
  • temp_trh_bottom
  • rh_bottom_fraction

sgp5ebbrE8.b1:
  • rh_bottom_fraction
  • vapor_pressure_top
  • temp_air_bottom
  • temp_air_top
  • vapor_pressure_bottom
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction

sgp15ebbrE8.b1:
  • temp_air_right
  • temp_air_left
  • rh_right_mv
  • rh_left_mv
  • temp_trh_right_rr
  • temp_trh_left_rr


Back To Table of Contents

DQRID : D051112.5
Start DateStart TimeEnd DateEnd Time
10/13/2003000007/22/20052359
Subject:
SGP/EBBR/E8 - metadata corrections
DataStreams:sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
Description:
On 20050723, a series of metadata corrections and additions were completed.  These 
metadata changes apply to all EBBR.E8 data collected by ARM back to the installation of the 
instrument in December 1992. Please see the current metadata for correct information.  These 
changes do not affect data values or quality.	

The changes are summarized below:
1) Update of "sensor location" information
2) Addition of installation dates for the systems
3) Correction of soil moisture units (from "by volume" to "gravimetric")
Measurements:sgp30ebbrE8.b1:
  • base time(base_time)

sgp5ebbrE8.b1:
  • base time(base_time)

sgp15ebbrE8.b1:
  • base time(base_time)


Back To Table of Contents



END OF DATA