Data Quality Reports for Session: 118958 User: dmfoper Completed: 04/17/2009


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D021113.1SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR
Header
sgp30ebbrE12.b1, sgp30ebbrE13.b1, sgp30ebbrE15.b1, sgp30ebbrE18.b1, sgp30ebbrE19.b1,
sgp30ebbrE2.b1, sgp30ebbrE20.b1, sgp30ebbrE22.b1, sgp30ebbrE26.b1, sgp30ebbrE4.b1,
sgp30ebbrE7.b1, sgp30ebbrE8.b1, sgp30ebbrE9.b1
D030620.1SGP/EBBR/E7 - Soil Heat Flow #5 Incorrectsgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1
D030729.3SGP/EBBR/E7 - AEM Malfunction, Some Data Incorrectsgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
D030917.2SGP/EBBR/E7 - Reprocess: Soil Heat Flow #5 Offscale, Surface Fluxes Incorrectsgp15ebbrE7.b1, sgp30ebbrE7.b1
D030919.1SGP/EBBR/E7 - Data all zerosgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
D030919.2SGP/EBBR/E7 - Energy Storage Incorrect, Fluxes Incorrectsgp30ebbrE7.a1, sgp30ebbrE7.b1
D030919.3SGP/EBBR/E7 - Water in Net Radiometer Domes; Surface Fluxes are Incorrectsgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
D031031.1SGP/EBBR/E7 - Reference Temperature Failuresgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1
D031204.6SGP/EBBR/E7 - 6 Month Checkssgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1
D031211.6SGP/EBBR/E7 - Pressure Sensor Data Incorrectsgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
D031222.9SGP/EBBR/E7 - Wind Speed Sensor Frozen By Ice Stormsgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1
D040206.3SGP/EBBR/E7 - Pressure Sensor Data Incorretsgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1
D040304.3SGP/EBBR/E7 - Wind Speed Frozen Stopped By Icesgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1
D040304.4SGP/EBBR/E7 - Tref Problem Causes All Temps. to be Incorrectsgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1
D040813.8SGP/EBBR/E7 - Pressure Too Highsgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1
D041005.3SGP/EBBR/E7 - Data Missingsgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1
D041222.8SGP/EBBR/E7 - 6 Month Checkssgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1
D050206.6SGP/EBBR/E7 - Wind Speed Frozen Stopped By Ice Stormsgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1
D050215.11SGP/EBBR/E7 - Wind Speed Frozen Stopped By Icesgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1
D050330.2SGP/EBBR/E7 - Wrong Datalogger Programsgp30ebbrE7.b1
D050719.6SGP/EBBR/E7 - Improved EBBR CR10 Programsgp30ebbrE7.b1
D051024.1SGP/EBBR/E7 - Data Missingsgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1
D051106.20SGP/EBBR/E7 - Average Soil Heat Flux Incorrectsgp30ebbrE7.b1
D051106.3SGP/EBBR/E7 - Net Radiation Incorrect; Sensible and Latent Heat Fluxes Incorrectsgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1
D051112.4SGP/EBBR/E7 - metadata correctionssgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1
D060111.3SGP/EBBR/E7 - Barometric Pressure Incorrectsgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1
D060501.4SGP/EBBR/E7 - Fluxes and Gradient Measurements Incorrectsgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1


DQRID : D021113.1
Start DateStart TimeEnd DateEnd Time
04/01/2001000006/18/20032359
Subject:
SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR 
Header
DataStreams:sgp30ebbrE12.b1, sgp30ebbrE13.b1, sgp30ebbrE15.b1, sgp30ebbrE18.b1, sgp30ebbrE19.b1,
sgp30ebbrE2.b1, sgp30ebbrE20.b1, sgp30ebbrE22.b1, sgp30ebbrE26.b1, sgp30ebbrE4.b1,
sgp30ebbrE7.b1, sgp30ebbrE8.b1, sgp30ebbrE9.b1
Description:
The units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in the 
EBBR 30 minute netcdf header have been incorrect from the beginning 
of processing the data into netcdf files.  The correct units are 
MJ/m^3/C.

This does not affect the data quality.
Measurements:sgp30ebbrE8.b1:
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_capacity_3
  • soil_heat_capacity_5
  • soil_heat_capacity_4

sgp30ebbrE4.b1:
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_5
  • soil_heat_capacity_1

sgp30ebbrE9.b1:
  • soil_heat_capacity_3
  • soil_heat_capacity_5
  • soil_heat_capacity_1
  • soil_heat_capacity_4
  • soil_heat_capacity_2

sgp30ebbrE18.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5

sgp30ebbrE26.b1:
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5
  • soil_heat_capacity_2
  • soil_heat_capacity_1

sgp30ebbrE13.b1:
  • soil_heat_capacity_3
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_1

sgp30ebbrE7.b1:
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_1

sgp30ebbrE12.b1:
  • soil_heat_capacity_2
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_1
  • soil_heat_capacity_5

sgp30ebbrE19.b1:
  • soil_heat_capacity_4
  • soil_heat_capacity_5
  • soil_heat_capacity_3
  • soil_heat_capacity_1
  • soil_heat_capacity_2

sgp30ebbrE20.b1:
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_capacity_5
  • soil_heat_capacity_3
  • soil_heat_capacity_4

sgp30ebbrE22.b1:
  • soil_heat_capacity_3
  • soil_heat_capacity_5
  • soil_heat_capacity_2
  • soil_heat_capacity_4
  • soil_heat_capacity_1

sgp30ebbrE2.b1:
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_1
  • soil_heat_capacity_3
  • soil_heat_capacity_2

sgp30ebbrE15.b1:
  • soil_heat_capacity_5
  • soil_heat_capacity_1
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • soil_heat_capacity_4


Back To Table of Contents

DQRID : D030620.1
Start DateStart TimeEnd DateEnd Time
06/11/2003173007/15/20032000
Subject:
SGP/EBBR/E7 - Soil Heat Flow #5 Incorrect
DataStreams:sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1
Description:
Soil Heat Flow Plate #5 data was intermittently incorrect at first 
(values too small negative), then was almost constantly so during the 
last half of the period.

Comparison of the individual soil heat flows will quickly show the times
that soil heat flow #5 was incorrect.
Measurements:sgp15ebbrE7.a1:
  • Soil heat flow 5(mv_hft5)

sgp30ebbrE7.a1:
  • average surface soil heat flow(ave_shf)
  • soil heat flow, site 5(g5)
  • 5 cm soil heat flow corrected for soil moisture content, site 5(c_shf5)
  • latent heat flux(e)
  • 5 cm soil heat flow, site 5(shf5)
  • h(h)

sgp15ebbrE7.b1:
  • soil_heat_flow_5_mv

sgp30ebbrE7.b1:
  • latent_heat_flux
  • corr_soil_heat_flow_5
  • sensible_heat_flux
  • surface_soil_heat_flux_avg
  • soil_heat_flow_5
  • surface_soil_heat_flux_5


Back To Table of Contents

DQRID : D030729.3
Start DateStart TimeEnd DateEnd Time
07/27/2003133010/07/20032000
Subject:
SGP/EBBR/E7  - AEM Malfunction, Some Data Incorrect
DataStreams:sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
Description:
After a while, the teflon slides on the AEMs warp from
heat and use.  This tends to make the AEM drag, jam, and get hung.
This happened at E7 EBBR.

Replacement of the AEM resolved the problem.
Measurements:sgp5ebbrE7.a1:
  • top air temperature(tair_top)
  • bottom vapor pressure(vp_bot)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • Temperature of the top humidity chamber(thum_top)
  • top vapor pressure(vp_top)
  • Top humidity(hum_top)
  • bottom air temperature(tair_bot)
  • Bottom humidity(hum_bot)

sgp15ebbrE7.a1:
  • Left air temperature(tair_l)
  • Right air temperature(tair_r)

sgp30ebbrE7.a1:
  • ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)
  • top air temperature(tair_top)
  • Top humidity(hum_top)
  • top vapor pressure(vp_top)
  • bottom air temperature(tair_bot)
  • bottom vapor pressure(vp_bot)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • latent heat flux(e)
  • h(h)
  • Bottom humidity(hum_bot)
  • Temperature of the top humidity chamber(thum_top)

sgp15ebbrE7.b1:
  • temp_air_right
  • temp_air_left

sgp30ebbrE7.b1:
  • temp_air_bottom
  • rh_bottom_fraction
  • latent_heat_flux
  • temp_trh_bottom
  • vapor_pressure_bottom
  • temp_trh_top
  • sensible_heat_flux
  • vapor_pressure_top
  • bowen_ratio
  • rh_top_fraction
  • temp_air_top


Back To Table of Contents

DQRID : D030917.2
Start DateStart TimeEnd DateEnd Time
10/13/2003000011/18/20032000
Subject:
SGP/EBBR/E7 - Reprocess: Soil Heat Flow #5 Offscale, Surface Fluxes Incorrect
DataStreams:sgp15ebbrE7.b1, sgp30ebbrE7.b1
Description:
Soil Heat Flow #5 went offscale at times.

Latent and Sensible Heat Fluxes were incorrect when this occurred.
Measurements:sgp30ebbrE7.b1:
  • surface_soil_heat_flux_avg
  • corr_soil_heat_flow_5
  • latent_heat_flux
  • soil_heat_flow_5
  • sensible_heat_flux
  • surface_soil_heat_flux_5

sgp15ebbrE7.b1:
  • soil_heat_flow_5_mv


Back To Table of Contents

DQRID : D030919.1
Start DateStart TimeEnd DateEnd Time
08/26/2003180008/26/20031800
Subject:
SGP/EBBR/E7 - Data all zero
DataStreams:sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
Description:
Data values were all zero after restarting the CR10 datalogger.
Measurements:sgp5ebbrE7.a1:
  • Temperature of the top humidity chamber(thum_top)
  • Reference Thermistor Temperature(tref)
  • Top humidity(hum_top)
  • Retrieved pressure profile(pres)
  • vector wind speed(res_ws)
  • standard deviation of wind direction (sigma theta)(sigma_wd)
  • net radiation(q)
  • Bottom humidity(hum_bot)
  • bottom vapor pressure(vp_bot)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • top vapor pressure(vp_top)
  • wind direction (relative to true north)(wind_d)
  • Home signal(home)
  • top air temperature(tair_top)
  • scalar wind speed(wind_s)
  • bottom air temperature(tair_bot)

sgp30ebbrE7.a1:
  • 0-5 cm change in soil heat storage with time, site 3(ces3)
  • wind direction (relative to true north)(wind_d)
  • soil heat flow, site 2(g2)
  • top air temperature(tair_top)
  • average surface soil heat flow(ave_shf)
  • vector wind speed(res_ws)
  • Exchange mechanism position indicator (0 to 15 min)(home_15)
  • volumetric soil moisture, site 5(sm5)
  • 0-5 cm change in soil heat storage with time, site 2(ces2)
  • 0-5 cm integrated soil temperature, site 2(ts2)
  • bottom air temperature(tair_bot)
  • volumetric soil moisture, site 4(sm4)
  • standard deviation of wind direction (sigma theta)(sigma_wd)
  • 0-5 cm integrated soil temperature, site 5(ts5)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • 0-5 cm integrated soil temperature, site 4(ts4)
  • volumetric soil moisture, site 2(sm2)
  • Soil heat capacity 2(cs2)
  • 5 cm soil heat flow corrected for soil moisture content, site 1(c_shf1)
  • volumetric soil moisture, site 1(sm1)
  • latent heat flux(e)
  • 0-5 cm change in soil heat storage with time, site 4(ces4)
  • soil heat flow, site 4(g4)
  • soil heat flow, site 3(g3)
  • Temperature of the top humidity chamber(thum_top)
  • 5 cm soil heat flow corrected for soil moisture content, site 2(c_shf2)
  • Soil heat capacity 5(cs5)
  • 5 cm soil heat flow corrected for soil moisture content, site 5(c_shf5)
  • 0-5 cm change in soil heat storage with time, site 5(ces5)
  • Soil heat capacity 3(cs3)
  • Retrieved pressure profile(pres)
  • Reference Thermistor Temperature(tref)
  • Soil heat capacity 1(cs1)
  • 5 cm soil heat flow, site 5(shf5)
  • 5 cm soil heat flow corrected for soil moisture content, site 4(c_shf4)
  • net radiation(q)
  • Exchange mechanism position indicator (15 to 30 min)(home_30)
  • Soil heat capacity 4(cs4)
  • 5 cm soil heat flow, site 1(shf1)
  • ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)
  • bottom vapor pressure(vp_bot)
  • 5 cm soil heat flow, site 4(shf4)
  • h(h)
  • 5 cm soil heat flow corrected for soil moisture content, site 3(c_shf3)
  • soil heat flow, site 1(g1)
  • Top humidity(hum_top)
  • soil heat flow, site 5(g5)
  • top vapor pressure(vp_top)
  • scalar wind speed(wind_s)
  • 5 cm soil heat flow, site 2(shf2)
  • 0-5 cm integrated soil temperature, site 3(ts3)
  • 5 cm soil heat flow, site 3(shf3)
  • 0-5 cm change in soil heat storage with time, site 2(ces1)
  • Bottom humidity(hum_bot)
  • volumetric soil moisture, site 3(sm3)
  • 0-5 cm integrated soil temperature, site 2(ts1)

sgp15ebbrE7.a1:
  • Soil moisture 5(r_sm5)
  • Atmospheric pressure(mv_pres)
  • Soil temperature 5(rr_ts5)
  • Left relative humidity(mv_hum_l)
  • Soil heat flow 5(mv_hft5)
  • Soil moisture 2(r_sm2)
  • Soil temperature 4(rr_ts4)
  • Soil heat flow 4(mv_hft4)
  • Soil moisture 3(r_sm3)
  • Battery(bat)
  • Wind direction (relative to true north)(mv_wind_d)
  • Left air temperature(tair_l)
  • Soil moisture 2(rr_sm2)
  • Right air temperature(tair_r)
  • Soil moisture 5(rr_sm5)
  • Soil moisture 1(r_sm1)
  • Soil moisture 3(rr_sm3)
  • Soil heat flow 1(mv_hft1)
  • Soil moisture 4(r_sm4)
  • Temperature of left humidity sensor chamber(rr_thum_l)
  • Temperature of right humidity sensor chamber(rr_thum_r)
  • Soil moisture 4(rr_sm4)
  • Right relative humidity(mv_hum_r)
  • Soil moisture 1(rr_sm1)
  • Soil temperature 2(rr_ts2)
  • Soil temperature 3(rr_ts3)
  • Soil heat flow 2(mv_hft2)
  • Soil heat flow 3(mv_hft3)
  • Net radiation(mv_q)
  • Home signal(mv_home)
  • Soil temperature 1(rr_ts1)
  • Reference temperature(rr_tref)
  • scalar wind speed(wind_s)

sgp15ebbrE7.b1:
  • soil_moisture_1_rr
  • soil_heat_flow_1_mv
  • soil_temp_4_rr
  • soil_heat_flow_4_mv
  • soil_moisture_3_rr
  • soil_temp_5_rr
  • atmos_pressure_mv
  • rh_right_mv
  • soil_temp_1_rr
  • net_radiation_mv
  • battery_voltage
  • soil_heat_flow_3_mv
  • soil_heat_flow_2_mv
  • soil_moisture_4_rr
  • temp_reference_rr
  • soil_moisture_5_rr
  • temp_air_right
  • temp_trh_right_rr
  • wdir_vec_mean_mv
  • temp_air_left
  • soil_temp_3_rr
  • wspd_arith_mean
  • temp_trh_left_rr
  • home_signal
  • soil_heat_flow_5_mv
  • soil_temp_2_rr
  • rh_left_mv
  • soil_moisture_2_rr

sgp30ebbrE7.b1:
  • corr_soil_heat_flow_5
  • soil_heat_capacity_5
  • soil_moisture_2
  • soil_heat_capacity_4
  • wspd_arith_mean
  • surface_soil_heat_flux_1
  • home_signal_15
  • energy_storage_change_4
  • vapor_pressure_top
  • surface_soil_heat_flux_2
  • soil_moisture_1
  • soil_moisture_3
  • corr_soil_heat_flow_4
  • surface_soil_heat_flux_avg
  • corr_soil_heat_flow_3
  • soil_moisture_5
  • energy_storage_change_5
  • soil_heat_capacity_1
  • vapor_pressure_bottom
  • temp_trh_top
  • sensible_heat_flux
  • soil_moisture_4
  • temp_reference
  • bowen_ratio
  • soil_heat_flow_1
  • Barometric Pressure(atmos_pressure)
  • temp_air_bottom
  • surface_soil_heat_flux_4
  • soil_temp_1
  • home_signal_30
  • soil_temp_4
  • surface_soil_heat_flux_3
  • soil_heat_flow_3
  • soil_temp_2
  • soil_heat_flow_2
  • wdir_vec_mean
  • soil_heat_capacity_2
  • soil_heat_flow_4
  • soil_heat_capacity_3
  • rh_bottom_fraction
  • soil_heat_flow_5
  • soil_temp_5
  • surface_soil_heat_flux_5
  • energy_storage_change_2
  • wspd_vec_mean
  • latent_heat_flux
  • energy_storage_change_3
  • energy_storage_change_1
  • corr_soil_heat_flow_1
  • wdir_vec_std
  • temp_trh_bottom
  • soil_temp_3
  • corr_soil_heat_flow_2
  • rh_top_fraction
  • net_radiation
  • temp_air_top


Back To Table of Contents

DQRID : D030919.2
Start DateStart TimeEnd DateEnd Time
08/26/2003183008/26/20031830
Subject:
SGP/EBBR/E7 - Energy Storage Incorrect, Fluxes Incorrect
DataStreams:sgp30ebbrE7.a1, sgp30ebbrE7.b1
Description:
The half hour after restart of the CR10 datalogger, the soil temperatures for the 
beginning of the period are missing.  Therefore the soil energy storage and surface flux values 
are also incorrect.
Measurements:sgp30ebbrE7.a1:
  • 0-5 cm change in soil heat storage with time, site 3(ces3)
  • soil heat flow, site 2(g2)
  • average surface soil heat flow(ave_shf)
  • soil heat flow, site 1(g1)
  • 0-5 cm change in soil heat storage with time, site 2(ces2)
  • soil heat flow, site 5(g5)
  • 0-5 cm change in soil heat storage with time, site 5(ces5)
  • latent heat flux(e)
  • 0-5 cm change in soil heat storage with time, site 4(ces4)
  • soil heat flow, site 4(g4)
  • 0-5 cm change in soil heat storage with time, site 2(ces1)
  • h(h)
  • soil heat flow, site 3(g3)

sgp30ebbrE7.b1:
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_avg
  • surface_soil_heat_flux_3
  • energy_storage_change_2
  • surface_soil_heat_flux_5
  • energy_storage_change_5
  • latent_heat_flux
  • energy_storage_change_1
  • energy_storage_change_3
  • surface_soil_heat_flux_1
  • energy_storage_change_4
  • sensible_heat_flux
  • surface_soil_heat_flux_2


Back To Table of Contents

DQRID : D030919.3
Start DateStart TimeEnd DateEnd Time
08/29/2003023009/05/20031730
Subject:
SGP/EBBR/E7 - Water in Net Radiometer Domes; Surface Fluxes are Incorrect
DataStreams:sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
Description:
The net radiometer top dome was punctured by migrating birds.  This alone does not cause 
incorrect net radiation measurements.  However, when it subsequently rains, water collects 
in the bottom dome, causing the net radiation measurements to be too large during the 
day and too small at night.
Measurements:sgp5ebbrE7.a1:
  • net radiation(q)

sgp15ebbrE7.a1:
  • Net radiation(mv_q)

sgp30ebbrE7.a1:
  • latent heat flux(e)
  • h(h)
  • net radiation(q)

sgp15ebbrE7.b1:
  • net_radiation_mv

sgp30ebbrE7.b1:
  • latent_heat_flux
  • sensible_heat_flux
  • net_radiation


Back To Table of Contents

DQRID : D031031.1
Start DateStart TimeEnd DateEnd Time
10/19/2003173010/19/20031930
10/20/2003133010/20/20031630
10/21/2003163010/21/20031830
10/22/2003000010/22/20031830
10/23/2003000010/23/20031630
Subject:
SGP/EBBR/E7  - Reference Temperature Failure
DataStreams:sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1
Description:
The reference T sensor was not working, affecting 
other temperature sensors.  Sensible and latent heat fluxes
were incorrect when this occurred.
Measurements:sgp15ebbrE7.b1:
  • temp_air_left
  • temp_air_right

sgp5ebbrE7.b1:
  • temp_air_top
  • temp_air_bottom

sgp30ebbrE7.b1:
  • latent_heat_flux
  • sensible_heat_flux
  • temp_air_bottom
  • bowen_ratio
  • temp_air_top


Back To Table of Contents

DQRID : D031204.6
Start DateStart TimeEnd DateEnd Time
11/04/2003220011/04/20032230
Subject:
SGP/EBBR/E7 - 6 Month Checks
DataStreams:sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp15ebbrE7.b1:
  • rh_right_mv
  • temp_air_right
  • temp_trh_left_rr
  • temp_air_left
  • temp_trh_right_rr
  • rh_left_mv

sgp30ebbrE7.b1:
  • temp_air_bottom
  • rh_bottom_fraction
  • latent_heat_flux
  • temp_trh_bottom
  • temp_trh_top
  • vapor_pressure_bottom
  • sensible_heat_flux
  • vapor_pressure_top
  • bowen_ratio
  • rh_top_fraction
  • temp_air_top

sgp5ebbrE7.b1:
  • temp_air_top
  • temp_air_bottom
  • rh_top_fraction
  • temp_trh_top
  • vapor_pressure_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D031211.6
Start DateStart TimeEnd DateEnd Time
03/07/2003150010/12/20032355
Subject:
SGP/EBBR/E7 - Pressure Sensor Data Incorrect
DataStreams:sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
Description:
The E7 pressure sensor suffered
from spikes in pressure, which were related to 
increases in voltage during the day as the 
solar panels charged the battery.  These spikes
were not of a magnitude that would affect the 
30 minute surface fluxes.

Replacement of the pressure sensor solved the problem.
Measurements:sgp5ebbrE7.a1:
  • Retrieved pressure profile(pres)

sgp15ebbrE7.b1:
  • atmos_pressure_mv

sgp30ebbrE7.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D031222.9
Start DateStart TimeEnd DateEnd Time
12/09/2003222012/10/20031200
Subject:
SGP/EBBR/E7 - Wind Speed Sensor Frozen By Ice Storm
DataStreams:sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1
Description:
The wind speed sensor was frozen stopped by ice.  The wind speed 
and residual wind speed measurements are incorrect.
Measurements:sgp30ebbrE7.b1:
  • wspd_arith_mean
  • wspd_vec_mean

sgp15ebbrE7.b1:
  • wspd_arith_mean

sgp5ebbrE7.b1:
  • wspd_arith_mean
  • wspd_vec_mean


Back To Table of Contents

DQRID : D040206.3
Start DateStart TimeEnd DateEnd Time
10/13/2003000001/28/20042030
Subject:
SGP/EBBR/E7 - Pressure Sensor Data Incorret
DataStreams:sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1
Description:
The E7 pressure sensor suffered
from spikes in pressure, which were related to 
increases in voltage during the day as the 
solar panels charged the battery.  These spikes
were not of a magnitude that would affect the 
30 minute surface fluxes.

Replacement of the pressure sensor solved the problem.
Measurements:sgp15ebbrE7.b1:
  • atmos_pressure_mv

sgp5ebbrE7.b1:
  • Barometric Pressure(atmos_pressure)

sgp30ebbrE7.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D040304.3
Start DateStart TimeEnd DateEnd Time
01/26/2004075501/28/20041550
02/02/2004084002/03/20041650
02/05/2004233002/06/20041210
Subject:
SGP/EBBR/E7  - Wind Speed Frozen Stopped By Ice
DataStreams:sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1
Description:
The wind speed sensor was frozen stopped by ice from a storm.  The wind speed 
and residual wind speed measurements are incorrect.
Measurements:sgp30ebbrE7.b1:
  • wspd_arith_mean
  • wspd_vec_mean

sgp15ebbrE7.b1:
  • wspd_arith_mean

sgp5ebbrE7.b1:
  • wspd_arith_mean
  • wspd_vec_mean


Back To Table of Contents

DQRID : D040304.4
Start DateStart TimeEnd DateEnd Time
02/19/2004212002/20/20040305
Subject:
SGP/EBBR/E7 - Tref Problem Causes All Temps. to be Incorrect
DataStreams:sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1
Description:
The Tref sensor went crazy for this brief period, making all temperature
measurements incorrect.
Measurements:sgp15ebbrE7.b1:
  • temp_air_left
  • temp_air_right

sgp5ebbrE7.b1:
  • temp_air_top
  • temp_reference
  • temp_air_bottom
  • temp_trh_top
  • temp_trh_bottom

sgp30ebbrE7.b1:
  • soil_temp_2
  • temp_trh_bottom
  • soil_temp_3
  • temp_trh_top
  • temp_air_bottom
  • soil_temp_1
  • soil_temp_4
  • soil_temp_5
  • temp_reference
  • temp_air_top


Back To Table of Contents

DQRID : D040813.8
Start DateStart TimeEnd DateEnd Time
08/10/2004192508/24/20041820
Subject:
SGP/EBBR/E7 - Pressure Too High
DataStreams:sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1
Description:
When data collection resumed after a missing period, the barometer pressure
had become very high, 102 kPa, which was not correct.  This condition resulted
from an incorrect calibration being used. Sensible heat flux was overestimated 
by about 4% and latent heat flux underestimated by about 4% because of the 
high pressure readings.
Measurements:sgp15ebbrE7.b1:
  • atmos_pressure_mv

sgp5ebbrE7.b1:
  • Barometric Pressure(atmos_pressure)

sgp30ebbrE7.b1:
  • latent_heat_flux
  • Barometric Pressure(atmos_pressure)
  • sensible_heat_flux
  • bowen_ratio


Back To Table of Contents

DQRID : D041005.3
Start DateStart TimeEnd DateEnd Time
08/04/2004170508/10/20041925
Subject:
SGP/EBBR/E7 - Data Missing
DataStreams:sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1
Description:
A power outage resulted in missing data for the indicated period.
Measurements:sgp15ebbrE7.b1:
  • soil_moisture_1_rr
  • soil_heat_flow_1_mv
  • lon(lon)
  • lat(lat)
  • soil_temp_4_rr
  • soil_heat_flow_4_mv
  • soil_moisture_3_rr
  • soil_temp_5_rr
  • rh_right_mv
  • atmos_pressure_mv
  • soil_temp_1_rr
  • base time(base_time)
  • net_radiation_mv
  • battery_voltage
  • soil_heat_flow_3_mv
  • soil_heat_flow_2_mv
  • soil_moisture_4_rr
  • temp_reference_rr
  • soil_moisture_5_rr
  • Time offset of tweaks from base_time(time_offset)
  • temp_air_right
  • Dummy altitude for Zeb(alt)
  • temp_air_left
  • wdir_vec_mean_mv
  • temp_trh_right_rr
  • soil_temp_3_rr
  • wspd_arith_mean
  • temp_trh_left_rr
  • home_signal
  • soil_heat_flow_5_mv
  • soil_temp_2_rr
  • rh_left_mv
  • soil_moisture_2_rr

sgp30ebbrE7.b1:
  • corr_soil_heat_flow_5
  • soil_heat_capacity_5
  • soil_moisture_2
  • lon(lon)
  • wspd_arith_mean
  • soil_heat_capacity_4
  • surface_soil_heat_flux_1
  • home_signal_15
  • energy_storage_change_4
  • vapor_pressure_top
  • surface_soil_heat_flux_2
  • soil_moisture_1
  • soil_moisture_3
  • corr_soil_heat_flow_4
  • surface_soil_heat_flux_avg
  • corr_soil_heat_flow_3
  • soil_moisture_5
  • energy_storage_change_5
  • soil_heat_capacity_1
  • vapor_pressure_bottom
  • temp_trh_top
  • sensible_heat_flux
  • soil_moisture_4
  • temp_reference
  • bowen_ratio
  • lat(lat)
  • soil_heat_flow_1
  • Barometric Pressure(atmos_pressure)
  • temp_air_bottom
  • surface_soil_heat_flux_4
  • soil_temp_1
  • home_signal_30
  • soil_temp_4
  • surface_soil_heat_flux_3
  • base time(base_time)
  • soil_heat_flow_3
  • soil_temp_2
  • soil_heat_flow_2
  • wdir_vec_mean
  • Time offset of tweaks from base_time(time_offset)
  • soil_heat_capacity_2
  • soil_heat_flow_4
  • rh_bottom_fraction
  • soil_heat_capacity_3
  • soil_temp_5
  • soil_heat_flow_5
  • surface_soil_heat_flux_5
  • energy_storage_change_2
  • wspd_vec_mean
  • latent_heat_flux
  • energy_storage_change_3
  • energy_storage_change_1
  • corr_soil_heat_flow_1
  • wdir_vec_std
  • soil_temp_3
  • temp_trh_bottom
  • Dummy altitude for Zeb(alt)
  • corr_soil_heat_flow_2
  • rh_top_fraction
  • net_radiation
  • temp_air_top

sgp5ebbrE7.b1:
  • wspd_vec_mean
  • base time(base_time)
  • temp_reference
  • vapor_pressure_top
  • lat(lat)
  • net_radiation
  • lon(lon)
  • Time offset of tweaks from base_time(time_offset)
  • home_signal
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • temp_air_bottom
  • rh_top_fraction
  • wdir_vec_std
  • temp_air_top
  • wdir_vec_mean
  • temp_trh_top
  • Dummy altitude for Zeb(alt)
  • time(time)
  • temp_trh_bottom
  • Barometric Pressure(atmos_pressure)
  • wspd_arith_mean


Back To Table of Contents

DQRID : D041222.8
Start DateStart TimeEnd DateEnd Time
10/05/2004200010/05/20042030
Subject:
SGP/EBBR/E7 - 6 Month Checks
DataStreams:sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp15ebbrE7.b1:
  • rh_right_mv
  • temp_air_right
  • temp_trh_left_rr
  • temp_air_left
  • temp_trh_right_rr
  • rh_left_mv

sgp30ebbrE7.b1:
  • temp_air_bottom
  • rh_bottom_fraction
  • latent_heat_flux
  • temp_trh_bottom
  • temp_trh_top
  • vapor_pressure_bottom
  • sensible_heat_flux
  • vapor_pressure_top
  • bowen_ratio
  • rh_top_fraction
  • temp_air_top

sgp5ebbrE7.b1:
  • temp_air_top
  • temp_air_bottom
  • rh_top_fraction
  • temp_trh_top
  • vapor_pressure_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D050206.6
Start DateStart TimeEnd DateEnd Time
01/04/2005145001/05/20050100
Subject:
SGP/EBBR/E7  - Wind Speed Frozen Stopped By Ice Storm
DataStreams:sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp30ebbrE7.b1:
  • wspd_arith_mean
  • wspd_vec_mean

sgp15ebbrE7.b1:
  • wspd_arith_mean

sgp5ebbrE7.b1:
  • wspd_arith_mean
  • wspd_vec_mean


Back To Table of Contents

DQRID : D050215.11
Start DateStart TimeEnd DateEnd Time
01/11/2005133001/12/20050050
Subject:
SGP/EBBR/E7  - Wind Speed Frozen Stopped By Ice
DataStreams:sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp30ebbrE7.b1:
  • wspd_arith_mean
  • wspd_vec_mean

sgp15ebbrE7.b1:
  • wspd_arith_mean

sgp5ebbrE7.b1:
  • wspd_arith_mean
  • wspd_vec_mean


Back To Table of Contents

DQRID : D050330.2
Start DateStart TimeEnd DateEnd Time
03/08/2005194503/22/20051900
Subject:
SGP/EBBR/E7 - Wrong Datalogger Program
DataStreams:sgp30ebbrE7.b1
Description:
The wrong version 9 datalogger program (unit 12 instead of 13) was installed
during the period listed, causing soil heat flows to be 2 to 3 W m-2 too
high, pressure to be 0.35 kPa too high, and soil moistures to be 10% too low.

Effects on the sensible and latent heat flow are much smaller than the system error.
Measurements:sgp30ebbrE7.b1:
  • Barometric Pressure(atmos_pressure)
  • corr_soil_heat_flow_5
  • soil_heat_capacity_5
  • soil_moisture_2
  • soil_moisture_3
  • corr_soil_heat_flow_4
  • surface_soil_heat_flux_4
  • soil_heat_capacity_2
  • surface_soil_heat_flux_avg
  • soil_heat_capacity_3
  • corr_soil_heat_flow_3
  • surface_soil_heat_flux_3
  • soil_moisture_5
  • surface_soil_heat_flux_5
  • energy_storage_change_2
  • soil_heat_capacity_4
  • energy_storage_change_5
  • energy_storage_change_1
  • energy_storage_change_3
  • surface_soil_heat_flux_1
  • corr_soil_heat_flow_1
  • soil_heat_capacity_1
  • energy_storage_change_4
  • soil_moisture_4
  • corr_soil_heat_flow_2
  • surface_soil_heat_flux_2
  • soil_moisture_1


Back To Table of Contents

DQRID : D050719.6
Start DateStart TimeEnd DateEnd Time
04/01/2001000003/22/20051900
Subject:
SGP/EBBR/E7 - Improved EBBR CR10 Program
DataStreams:sgp30ebbrE7.b1
Description:
Effective 20050322.1900, the EBBR.E7 CR10 program was revised to improve 
the quality of the primary measurements as follows:
   
1) An RMS procedure is used to determine max and min limits of acceptable
soil heat flow.  This is applied to the individual soil sets.  Measurements
outside the limits are rejected and the measurements within the limits are
used to calculate the average soil heat flow.
   
2) Max and min limits are used to determine incorrect values of net
radiation, sensible heat flux (h), latent heat flux (e), and automatic
exchange mechanism (AEM) signal.  If AEM signal is outside the limits, h 
and e are set to 999s.  If net radiation is outside the limits, h and e are 
set to 999s. If h or e are outside the limits, h and e are set to 999s.
   
Virtually no incorrect soil measurement will affect the primary 
measurements of h and e.
   
By setting h and e to 999s, it can be easily seen that the primary 
variables are incorrect; no other interpretation is possible.
   
Prior to 20050322, the improved CR10 program was NOT in effect.  DQRs have
been submitted for known instances of incorrect soil measurements which
affected the quality of the primary measurements of h and e.
   
Note: the DQR begin date is the begin date of the sgp30ebbrE7.b1 data
stream.  The earlier version of the CR10 program was also used on previous
EBBR datastream names (e.g. sgp30ebbrE7.a1).
Measurements:sgp30ebbrE7.b1:
  • surface_soil_heat_flux_avg
  • latent_heat_flux
  • sensible_heat_flux


Back To Table of Contents

DQRID : D051024.1
Start DateStart TimeEnd DateEnd Time
09/20/2005203010/07/20051530
Subject:
SGP/EBBR/E7 - Data Missing
DataStreams:sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1
Description:
Data was missing because of a communication problem.  However, previously
missing data from 10/07-18 was recovered from the EBRR storage module and ingested, 
thereby reducing the data lost period significantly.
Measurements:sgp15ebbrE7.b1:
  • soil_moisture_1_rr
  • soil_heat_flow_1_mv
  • lon(lon)
  • lat(lat)
  • soil_temp_4_rr
  • soil_heat_flow_4_mv
  • soil_moisture_3_rr
  • soil_temp_5_rr
  • rh_right_mv
  • atmos_pressure_mv
  • soil_temp_1_rr
  • base time(base_time)
  • net_radiation_mv
  • battery_voltage
  • soil_heat_flow_3_mv
  • soil_heat_flow_2_mv
  • soil_moisture_4_rr
  • temp_reference_rr
  • soil_moisture_5_rr
  • Time offset of tweaks from base_time(time_offset)
  • temp_air_right
  • Dummy altitude for Zeb(alt)
  • temp_air_left
  • wdir_vec_mean_mv
  • temp_trh_right_rr
  • soil_temp_3_rr
  • wspd_arith_mean
  • temp_trh_left_rr
  • home_signal
  • soil_heat_flow_5_mv
  • soil_temp_2_rr
  • rh_left_mv
  • soil_moisture_2_rr

sgp30ebbrE7.b1:
  • corr_soil_heat_flow_5
  • soil_heat_capacity_5
  • soil_moisture_2
  • lon(lon)
  • wspd_arith_mean
  • soil_heat_capacity_4
  • surface_soil_heat_flux_1
  • home_signal_15
  • energy_storage_change_4
  • vapor_pressure_top
  • surface_soil_heat_flux_2
  • soil_moisture_1
  • soil_moisture_3
  • corr_soil_heat_flow_4
  • surface_soil_heat_flux_avg
  • corr_soil_heat_flow_3
  • soil_moisture_5
  • energy_storage_change_5
  • soil_heat_capacity_1
  • vapor_pressure_bottom
  • temp_trh_top
  • sensible_heat_flux
  • soil_moisture_4
  • temp_reference
  • bowen_ratio
  • lat(lat)
  • soil_heat_flow_1
  • Barometric Pressure(atmos_pressure)
  • temp_air_bottom
  • surface_soil_heat_flux_4
  • soil_temp_1
  • home_signal_30
  • soil_temp_4
  • surface_soil_heat_flux_3
  • base time(base_time)
  • soil_heat_flow_3
  • soil_temp_2
  • soil_heat_flow_2
  • wdir_vec_mean
  • Time offset of tweaks from base_time(time_offset)
  • soil_heat_capacity_2
  • soil_heat_flow_4
  • rh_bottom_fraction
  • soil_heat_capacity_3
  • soil_temp_5
  • soil_heat_flow_5
  • surface_soil_heat_flux_5
  • energy_storage_change_2
  • wspd_vec_mean
  • latent_heat_flux
  • energy_storage_change_3
  • energy_storage_change_1
  • corr_soil_heat_flow_1
  • wdir_vec_std
  • soil_temp_3
  • temp_trh_bottom
  • Dummy altitude for Zeb(alt)
  • corr_soil_heat_flow_2
  • rh_top_fraction
  • net_radiation
  • temp_air_top

sgp5ebbrE7.b1:
  • wspd_vec_mean
  • base time(base_time)
  • temp_reference
  • vapor_pressure_top
  • lat(lat)
  • net_radiation
  • lon(lon)
  • Time offset of tweaks from base_time(time_offset)
  • home_signal
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • temp_air_bottom
  • rh_top_fraction
  • wdir_vec_std
  • temp_air_top
  • wdir_vec_mean
  • temp_trh_top
  • Dummy altitude for Zeb(alt)
  • time(time)
  • temp_trh_bottom
  • Barometric Pressure(atmos_pressure)
  • wspd_arith_mean


Back To Table of Contents

DQRID : D051106.20
Start DateStart TimeEnd DateEnd Time
03/08/2005200003/22/20051900
Subject:
SGP/EBBR/E7 - Average Soil Heat Flux Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
A typo in the version 9 EBBR program caused average soil heat flow to be zero, resulting 
in both sensible and latent heat fluxes being approximately 20 watts per meter squared too 
large during the middle of the day.
Measurements:sgp30ebbrE7.b1:
  • surface_soil_heat_flux_avg
  • latent_heat_flux
  • sensible_heat_flux


Back To Table of Contents

DQRID : D051106.3
Start DateStart TimeEnd DateEnd Time
09/14/2005000009/20/20052000
Subject:
SGP/EBBR/E7 - Net Radiation Incorrect; Sensible and Latent Heat Fluxes Incorrect
DataStreams:sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1
Description:
The top dome of the net radiometer was cracked; net radiation, and sensible and latent 
heat flux measurements were incorrect.
Measurements:sgp5ebbrE7.b1:
  • net_radiation

sgp15ebbrE7.b1:
  • net_radiation_mv

sgp30ebbrE7.b1:
  • latent_heat_flux
  • sensible_heat_flux
  • net_radiation


Back To Table of Contents

DQRID : D051112.4
Start DateStart TimeEnd DateEnd Time
10/13/2003000007/22/20052359
Subject:
SGP/EBBR/E7 - metadata corrections
DataStreams:sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1
Description:
On 20050723, a series of metadata corrections and additions were completed.  These 
metadata changes apply to all EBBR.E7 data collected by ARM back to the installation of the 
instrument in May 1993. Please see the current metadata for correct information.  These 
changes do not affect data values or quality.	

The changes are summarized below:
1) Update of "sensor location" information
2) Addition of installation dates for the systems
3) Correction of soil moisture units (from "by volume" to "gravimetric")
Measurements:sgp5ebbrE7.b1:
  • base time(base_time)

sgp30ebbrE7.b1:
  • base time(base_time)

sgp15ebbrE7.b1:
  • base time(base_time)


Back To Table of Contents

DQRID : D060111.3
Start DateStart TimeEnd DateEnd Time
12/04/2005170002/20/20062230
Subject:
SGP/EBBR/E7 - Barometric Pressure Incorrect
DataStreams:sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1
Description:
The pressure measurement sometimes dropped to zero during daytime because of 
unstable battery voltage.
Measurements:sgp15ebbrE7.b1:
  • atmos_pressure_mv

sgp5ebbrE7.b1:
  • Barometric Pressure(atmos_pressure)

sgp30ebbrE7.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D060501.4
Start DateStart TimeEnd DateEnd Time
03/21/2006100003/21/20062030
Subject:
SGP/EBBR/E7 - Fluxes and Gradient Measurements Incorrect
DataStreams:sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1
Description:
The left AEM aspirator was not working during this period, resulting in incorrect gradient 
and flux measurements.
Measurements:sgp5ebbrE7.b1:
  • temp_air_top
  • temp_air_bottom
  • rh_top_fraction
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_trh_top
  • vapor_pressure_bottom
  • temp_trh_bottom

sgp30ebbrE7.b1:
  • latent_heat_flux
  • temp_trh_bottom
  • vapor_pressure_bottom
  • temp_trh_top
  • sensible_heat_flux
  • temp_air_bottom
  • vapor_pressure_top
  • rh_bottom_fraction
  • bowen_ratio
  • rh_top_fraction
  • temp_air_top

sgp15ebbrE7.b1:
  • temp_trh_left_rr
  • temp_air_left
  • rh_left_mv


Back To Table of Contents