Data Quality Reports for Session: 118251 User: dmfoper Completed: 03/17/2009


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D070912.1SGP/IRT/E13 - Missing datasgpirt200msE13.a1, sgpirtE13.b1
D071217.6SGP/IRT/E15 - Instrument noise problemsgpirt200msE15.a1, sgpirtE15.00, sgpirtE15.b1
D080131.1SGP/IRT/E13 - Reprocess: Sky temperature biassgpirt200msE13.a1, sgpirtE13.b1
D081217.1SGP/IRT/E13 - Reprocess: wrong unitssgpirt200msE13.a1, sgpirtE13.b1


DQRID : D070912.1
Start DateStart TimeEnd DateEnd Time
07/25/2007220007/27/20071457
08/29/2007132809/06/20072000
09/08/2007070009/10/20071937
09/11/2007000109/19/20071410
09/20/2007015110/10/20072118
10/11/2007015610/31/20071852
12/22/2007184812/26/20072006
01/07/2008000001/10/20081430
01/28/2008185701/30/20081631
02/09/2008200202/13/20081414
02/13/2008204002/22/20081815
03/02/2008043003/07/20081736
03/09/2008220005/02/20082209
05/03/2008175605/27/20081148
05/27/2008173208/04/20080708
08/04/2008140010/16/20082018
Subject:
SGP/IRT/E13 - Missing data
DataStreams:sgpirt200msE13.a1, sgpirtE13.b1
Description:
Data are missing and unrecoverable.
Measurements:sgpirt200msE13.a1:
  • Internal Reference Infra Red Temperature(ref_ir_temp)
  • base time(base_time)
  • time(time)
  • Dummy altitude for Zeb(alt)
  • Time offset of tweaks from base_time(time_offset)
  • Sky Infra-Red Temperature(sky_ir_temp)
  • lon(lon)
  • lat(lat)

sgpirtE13.b1:
  • Internal Reference Infra Red Temperature(ref_ir_temp)
  • lat(lat)
  • Sky Infra-Red Temperature(sky_ir_temp)
  • Sky Infra Red Temperature Minima(sky_ir_temp_min)
  • Standard Deviation of Sky Infra Red Temperature(sky_ir_temp_std)
  • base time(base_time)
  • Number of Samples Averaged(samples_in_average)
  • Dummy altitude for Zeb(alt)
  • Sky Infra Red Temperature Maxima(sky_ir_temp_max)
  • lon(lon)
  • Time offset of tweaks from base_time(time_offset)
  • Standard Deviation of Internal Reference Infra Red Temperature(ref_ir_temp_std)
  • time(time)


Back To Table of Contents

DQRID : D071217.6
Start DateStart TimeEnd DateEnd Time
07/12/2005153003/28/20081722
Subject:
SGP/IRT/E15 - Instrument noise problem
DataStreams:sgpirt200msE15.a1, sgpirtE15.00, sgpirtE15.b1
Description:
The data was much noisier than other nearby sites (a factor of 4-5 times more). The 
connections and communication and other settings were checked. The IRT was replaced on 
1/29/2008 at 17:37 but the response time was incorrectly set to 0.01 s. This problem was 
corrected when the setting was changed to 0.10 s.
Measurements:sgpirtE15.b1:
  • Sky Infra Red Temperature Minima(sky_ir_temp_min)
  • Sky Infra-Red Temperature(sky_ir_temp)

sgpirt200msE15.a1:
  • Sky Infra-Red Temperature(sky_ir_temp)

sgpirtE15.00:
  • Raw data stream - documentation not supported(raw)


Back To Table of Contents

DQRID : D080131.1
Start DateStart TimeEnd DateEnd Time
01/11/2006000007/25/20072315
Subject:
SGP/IRT/E13 - Reprocess: Sky temperature bias
DataStreams:sgpirt200msE13.a1, sgpirtE13.b1
Description:
Measurements of sky temperature, especially those <250K,, were positively biased compared 
with AERI because there was no compensation for the effect of the emissivity and 
temperature of the gold mirror. The problem was corrected by changing the IRT emissivity from 
1.000 to 0.987, adding an RTD and transmitter electronics to measure the temperature of the 
mirror, and changing the ambient temperature measurement for internal reference to 
external mirror temperature.

Use sky temperature measurements less than 230K with caution. Biases as large as 30K have 
been observed when the actual temperature, as measured by AERI, is less than 210 K.
Measurements:sgpirt200msE13.a1:
  • Sky Infra-Red Temperature(sky_ir_temp)

sgpirtE13.b1:
  • Sky Infra Red Temperature Maxima(sky_ir_temp_max)
  • Sky Infra-Red Temperature(sky_ir_temp)
  • Sky Infra Red Temperature Minima(sky_ir_temp_min)


Back To Table of Contents

DQRID : D081217.1
Start DateStart TimeEnd DateEnd Time
09/12/2008211010/27/20082030
Subject:
SGP/IRT/E13 - Reprocess: wrong units
DataStreams:sgpirt200msE13.a1, sgpirtE13.b1
Description:
While diagnosing serial communication problems, the IRT configuration was reset to factory 
defaults so the temperature unit parameter was set to C instead of K.
Measurements:sgpirt200msE13.a1:
  • Internal Reference Infra Red Temperature(ref_ir_temp)
  • Sky Infra-Red Temperature(sky_ir_temp)

sgpirtE13.b1:
  • Internal Reference Infra Red Temperature(ref_ir_temp)
  • Sky Infra Red Temperature Maxima(sky_ir_temp_max)
  • Sky Infra-Red Temperature(sky_ir_temp)
  • Sky Infra Red Temperature Minima(sky_ir_temp_min)


Back To Table of Contents



END OF DATA