Data Quality Reports for Session: 118147 User: anderberg Completed: 03/12/2009


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D080904.5NSA/GNDRAD/C1 - Upwelling PIR ventilator fan failurensagndrad20sC1.a0, nsagndrad60sC1.b1


DQRID : D080904.5
Start DateStart TimeEnd DateEnd Time
07/20/2008033009/15/20081930
Subject:
NSA/GNDRAD/C1 - Upwelling PIR ventilator fan failure
DataStreams:nsagndrad20sC1.a0, nsagndrad60sC1.b1
Description:
The PIR exhibited a positive bias of approximately 6 W/m2 compared to the upwelling IRT 
due to ventilator fan failure.  Thus, the up_long_hemisp, data stream is high by about 6 
W/m2.    
   
Bias is not consistent and depends on atmospheric conditions. Either disregard the 
up_long_hemisp data or use the IRT for an estimate of the up_long_hemisp values during this time 
period.
Measurements:nsagndrad20sC1.a0:
  • Instantaneous Upwelling Pyrgeometer Case Thermistor Resistance, Pyrgeometer(inst_up_long_hemisp_case_resist)
  • Instantaneous Upwelling Pyrgeometer Thermopile(inst_up_long_hemisp_tp)
  • Instantaneous Upwelling Pyrgeometer Dome Thermistor Resistance, Pyrgeometer(inst_up_long_hemisp_dome_resist)

nsagndrad60sC1.b1:
  • Instantaneous Upwelling Pyrgeometer Dome Thermistor Temperature(inst_up_long_hemisp_dome_temp)
  • Upwelling (10 meter) Longwave Hemispheric Irradiance, Pyrgeometer, Standard
    Deviation(up_long_hemisp_std)
  • Instantaneous Upwelling Pyrgeometer Thermopile(inst_up_long_hemisp_tp)
  • Upwelling (10 meter) Longwave Hemispheric Irradiance, Pyrgeometer, Maxima(up_long_hemisp_max)
  • Instantaneous Upwelling Pyrgeometer Case Thermistor Temperature(inst_up_long_hemisp_case_temp)
  • Upwelling (10 meter) Longwave Hemispheric Irradiance, Pyrgeometer(up_long_hemisp)
  • Upwelling (10 meter) Longwave Hemispheric Irradiance, Pyrgeometer, Minima(up_long_hemisp_min)