Data Quality Reports for Session: 117804 User: dholdridge Completed: 02/25/2009


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D050418.2TWP/SMET/C3 - Lower wind direction sensor failuretwpsmet60sC3.b1
D061011.4TWP/SMET/C3 - Reprocess: Tipping bucket rain gauge addedtwpsmet60sC3.b1
D081022.8TWP/SMET/C3 - Wind Speed data contain offset due to induced voltagetwpsmet60sC3.b1


DQRID : D050418.2
Start DateStart TimeEnd DateEnd Time
04/14/2005023004/19/20050050
Subject:
TWP/SMET/C3 - Lower wind direction sensor failure
DataStreams:twpsmet60sC3.b1
Description:
The lower wind direction sensor failed on 4/14 and disagrees significantly with the upper 
wind direction sensor.  The lower wind sensor reports a constant value around 0-15 
degrees since it failed.  Testing showed that excitation channel two on the logger was the 
problem.  Logger was replaced by spare.
Measurements:twpsmet60sC3.b1:
  • Lower sensor, wind direction vector average(lo_dir_vec_avg)
  • Lower sensor, wind direction standard deviation(lo_dir_sd)


Back To Table of Contents

DQRID : D061011.4
Start DateStart TimeEnd DateEnd Time
03/12/2002000009/26/20061435
Subject:
TWP/SMET/C3 - Reprocess: Tipping bucket rain gauge added
DataStreams:twpsmet60sC3.b1
Description:
A tipping bucket rain gauge was added to the SMET suite of instruments effective 20060926. 
 Two new variables (count and rain amount) were added at the end of the twpsmet60sC1.b1 
datastream.  When reprocessing of this datastream occurs these variables will be added 
with -9999 (missing) as the value for dates prior to gauge installation.
Measurements:twpsmet60sC3.b1:
  • base time(base_time)


Back To Table of Contents

DQRID : D081022.8
Start DateStart TimeEnd DateEnd Time
03/12/2004000010/17/20080627
Subject:
TWP/SMET/C3 - Wind Speed data contain offset due to induced voltage
DataStreams:twpsmet60sC3.b1
Description:
The marine model of the RM Young wind sensor needs twisted pair shielded cable.  The 
manufacturer did not originally supply the pigtail with twisted pair shielded cable.  Use of 
twisted pair shielded cable for the rest of the cable run to the logger was also not 
specified.  This caused an induced voltage in the wind speed line from the wind direction 
excitation.  The induced voltage varied from sensor to sensor and probably changed anytime 
the cable was replaced or parts of the wind sensor were repaired or replaced. The induced 
voltage has been seen to vary from 0.15 m/s to as much as 1.08 m/s.
Measurements:twpsmet60sC3.b1:
  • Upper sensor, wind speed maximum(up_spd_max)
  • Lower sensor, wind speed minimum(lo_spd_min)
  • Lower sensor, wind speed standard deviation(lo_spd_sd)
  • Lower sensor, wind speed maximum(lo_spd_max)
  • Upper sensor, wind speed arithmetic average(up_spd_arith_avg)
  • Lower sensor, wind speed vector average(lo_spd_vec_avg)
  • Upper sensor, wind speed minimum(up_spd_min)
  • Lower sensor, wind speed arithmetic average(lo_spd_arith_avg)
  • Upper sensor, wind speed vector average(up_spd_vec_avg)
  • Upper sensor, wind speed standard deviation(up_spd_sd)


Back To Table of Contents



END OF DATA