Data Quality Reports for Session: 115764 User: sherman Completed: 11/17/2008


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D071115.1SGP/EBBR/E20 - Reprocess: Wind Direction 65 Degrees Lowsgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1
D080930.2SGP/IRT/C1 - Contamination of 25M lenssgpirt25mC1.b1


DQRID : D071115.1
Start DateStart TimeEnd DateEnd Time
10/15/2007000010/24/20071900
Subject:
SGP/EBBR/E20 - Reprocess: Wind Direction 65 Degrees Low
DataStreams:sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1
Description:
The wind direction sensor reported wind directions that were 65 degrees too low because of 
a mis-alignment.

This bias should have no effect on the res_ws or sigma_wd measurements.

The wind direction data could be re-processed by adding 65 degrees.
Measurements:sgp30ebbrE20.b1:
  • wind direction (relative to true north)(wind_d)

sgp15ebbrE20.b1:
  • Wind direction (relative to true north)(mv_wind_d)

sgp5ebbrE20.b1:
  • wind direction (relative to true north)(wind_d)


Back To Table of Contents

DQRID : D080930.2
Start DateStart TimeEnd DateEnd Time
05/25/2008000010/01/20081905
Subject:
SGP/IRT/C1 - Contamination of 25M lens
DataStreams:sgpirt25mC1.b1
Description:
The IRT exhibited a positive bias compared to PIR. The problem was corrected by cleaning 
the lens.
Measurements:sgpirt25mC1.b1:
  • Instantaneous Surface Infra-red Temperature(inst_sfc_ir_temp)
  • Surface Infra-Red Temperature, Standard Deviation(sfc_ir_temp_std)
  • Effective Surface (Skin) Temperature(sfc_ir_temp)
  • Surface Infra-Red Temperature Minima(sfc_ir_temp_min)
  • Surface Infra-Red Temperature Maxima(sfc_ir_temp_max)


Back To Table of Contents