Data Quality Reports for Session: 115708 User: sherman Completed: 11/13/2008


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D040428.1TWP/SMET/C1 - Poor Performing Sensortwpsmet60sC1.b1
D040722.7TWP/SMET/C2 - connection and timing issues with new loggertwpsmet60sC2.b1
D040824.2TWP/SMET/C2 - Incorrect rainrate equation used.twpsmet60sC2.b1
D050301.1TWP/SMET/C2 - Upper wind direction sensor failuretwpsmet60sC2.b1
D050322.2TWP/SMET/C2 - Upper wind direction sensor failuretwpsmet60sC2.b1
D050714.1TWP/SMET/C2 - RH sensor failuretwpsmet60sC2.b1
D060522.1TWP/SMET/C1 - Upper wind sensor failuretwpsmet60sC1.b1
D061011.2TWP/SMET/C1 - Reprocess: Tipping bucket rain gauge addedtwpsmet60sC1.b1
D061011.3TWP/SMET/C2 - Reprocess: Tipping bucket rain gauge addedtwpsmet60sC2.b1


DQRID : D040428.1
Start DateStart TimeEnd DateEnd Time
04/23/2004000001/19/20051530
Subject:
TWP/SMET/C1 - Poor Performing Sensor
DataStreams:twpsmet60sC1.b1
Description:
On 4/23/2004 condensation was found inside the target area of the ORG lens. A spare was 
sent and installed but did not solve the problem of high background voltage values causing 
rainrate values to be recorded during no rainfall.  Values range anywhere from 0.06 to 
0.12 mm/hr.  

A new Optical Rain Gage was installed on 01/19/2005 @ 13:30 GMT alleviating the high 
background voltage values that lead to consistent rainfall rates of around 0.11 to 0.15 mm/hr 
on a consistent basis.  

The formula used to calculate rainfall rates from the new Optical Rain Gage is:  RR 
(mm/hr) = 25(V^1.87) - 0.15.

Older model formula = 20(V^2) - 0.05

The two formulas result in comparable data.
Measurements:twpsmet60sC1.b1:
  • Precipitation mean(precip_mean)
  • Precipitation maximum(precip_max)
  • Precipitation standard deviation(precip_sd)
  • precipitation minimum(precip_min)


Back To Table of Contents

DQRID : D040722.7
Start DateStart TimeEnd DateEnd Time
07/07/2004013807/07/20042018
Subject:
TWP/SMET/C2 - connection and timing issues with new logger
DataStreams:twpsmet60sC2.b1
Description:
Atmospheric pressure data are intermittent during this time period due to connection 
problems and program timing issues with new logger installation.  Data resumed normal 
operations after this time period.
Measurements:twpsmet60sC2.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D040824.2
Start DateStart TimeEnd DateEnd Time
07/07/2004013708/17/20042157
Subject:
TWP/SMET/C2 - Incorrect rainrate equation used.
DataStreams:twpsmet60sC2.b1
Description:
There are two different Optical Raingages in use at the TWP sites.  The incorrect equation 
was used at this site.  The incorrect equation is (25*(V^1.87)) - 0.15.
The correct equation is (20*(V^2)) - 0.05.  The correct equation was installed.
Measurements:twpsmet60sC2.b1:
  • Precipitation maximum(precip_max)
  • Precipitation mean(precip_mean)
  • precipitation minimum(precip_min)
  • Precipitation standard deviation(precip_sd)


Back To Table of Contents

DQRID : D050301.1
Start DateStart TimeEnd DateEnd Time
02/12/2005195503/03/20050430
Subject:
TWP/SMET/C2 - Upper wind direction sensor failure
DataStreams:twpsmet60sC2.b1
Description:
The upper wind direction sensor failed. Wind direction was reported at a near constant 
value of 69 degrees and was significantly different than the lower wind sensor's direction 
values. Sensor replaced.
Measurements:twpsmet60sC2.b1:
  • Upper sensor, wind direction vector average(up_dir_vec_avg)
  • Upper sensor, wind direction standard deviation(up_dir_sd)


Back To Table of Contents

DQRID : D050322.2
Start DateStart TimeEnd DateEnd Time
03/09/2005230004/17/20050332
Subject:
TWP/SMET/C2 - Upper wind direction sensor failure
DataStreams:twpsmet60sC2.b1
Description:
After replacement on 03/03/2005 the upper wind direction sensor began reporting erroneous 
values again on 03/09/2005 becoming very apparent after 03/17/2005.  Wind speed data 
appears reasonable but the wind direction data do not agree well with the lower wind sensor.
Measurements:twpsmet60sC2.b1:
  • Upper sensor, wind direction vector average(up_dir_vec_avg)
  • Upper sensor, wind direction standard deviation(up_dir_sd)


Back To Table of Contents

DQRID : D050714.1
Start DateStart TimeEnd DateEnd Time
07/10/2005190007/14/20052226
Subject:
TWP/SMET/C2 - RH sensor failure
DataStreams:twpsmet60sC2.b1
Description:
Relative humidity values were frequently over MAX value of 104% starting on 7/10/2005 
through end of period.  Sensor was replaced.
Measurements:twpsmet60sC2.b1:
  • Mean Relative Humidity(relh_mean)
  • Std Dev of Relative Humidity or Hardware Error Code(relh_sd)


Back To Table of Contents

DQRID : D060522.1
Start DateStart TimeEnd DateEnd Time
05/09/2006000010/14/20060237
Subject:
TWP/SMET/C1 - Upper wind sensor failure
DataStreams:twpsmet60sC1.b1
Description:
The upper wind speed sensor was binding at low wind speeds.  Comparison to the lower wind 
sensor showed that the upper sensor flat-lines for long periods of time.  The upper 
anemometer was replaced.
Measurements:twpsmet60sC1.b1:
  • Upper sensor, wind direction standard deviation(up_dir_sd)
  • Upper sensor, wind direction vector average(up_dir_vec_avg)
  • Upper sensor, wind speed maximum(up_spd_max)
  • Upper sensor, wind speed arithmetic average(up_spd_arith_avg)
  • Upper sensor, wind speed vector average(up_spd_vec_avg)
  • Upper sensor, wind speed minimum(up_spd_min)
  • Upper sensor, wind speed standard deviation(up_spd_sd)


Back To Table of Contents

DQRID : D061011.2
Start DateStart TimeEnd DateEnd Time
10/09/1996000010/17/20060000
Subject:
TWP/SMET/C1 - Reprocess: Tipping bucket rain gauge added
DataStreams:twpsmet60sC1.b1
Description:
A tipping bucket rain gauge was added to the TWP.C1 SMET suite of instruments on 20061017. 
 Effective 20060926, two new variables (count and rain amount) were added to the end of 
the twpsmet60sC1.b1 datastream.  Between 9/26 and 10/17, the data for these two variables 
are filled with zeros.  Users should not use the data during this period as the zeros 
are not representative of the rain fall at the site.  When reprocessing of this datastream 
occurs these variables will be added for the 19961009-20060926 and data from 
19961009-20061017 will be filled with -9999 (missing).
Measurements:twpsmet60sC1.b1:
  • base time(base_time)


Back To Table of Contents

DQRID : D061011.3
Start DateStart TimeEnd DateEnd Time
10/21/1998000011/29/20062014
Subject:
TWP/SMET/C2 - Reprocess: Tipping bucket rain gauge added
DataStreams:twpsmet60sC2.b1
Description:
A tipping bucket rain gauge was added to the TWP.C2 SMET suite of instruments on 20061129. 
Effective 20060926, two new variables (count and rain amount) were added to the end of 
the twpsmet60sC2.b1 datastream.  Between 9/26 and 11/29, the data for these two variables 
are filled with zeros.  Users should not use the data during this period as the zeros are 
not representative of the rain fall at the site.  When reprocessing of this datastream 
occurs these variables will be added for the 19981021-20060926 and data from 
19981021-20061129 will be filled with -9999 (missing).
Measurements:twpsmet60sC2.b1:
  • base time(base_time)


Back To Table of Contents



END OF DATA