Data Quality Reports for Session: 115611 User: sherman Completed: 11/10/2008


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D060802.1SGP/SWATS/E12 - T_rise higher than QC checkssgpswatsE12.b1


DQRID : D060802.1
Start DateStart TimeEnd DateEnd Time
07/12/2006000008/15/20061800
Subject:
SGP/SWATS/E12 - T_rise higher than QC checks
DataStreams:sgpswatsE12.b1
Description:
T-rise way to high (~40 deg C).  Water potential is calculated from a rise (and subsequent 
drop) in temperature in the sensor that is normally ~1-5 degrees C.  When the T_rise is 
too high, the soil moisture data is dubious at best and unusable at worst.  Since this 
"out-of-bounds" t_rise is so high, the soil moisture data are practically unusable.
Measurements:sgpswatsE12.b1:
  • Soil Water Potential, West Profile(soilwatpot_W)
  • Volumetric Water Content, West Profile(watcont_W)
  • Soil Water Potential, East Profile(soilwatpot_E)
  • Volumetric Water Content, East Profile(watcont_E)


Back To Table of Contents



END OF DATA