Data Quality Reports for Session: 115561 User: sherman Completed: 11/07/2008


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D040831.4SGP/SIRS/E10 - Reprocess: Incorrect shortwave radiometer calibration coefficientssgpsirsE10.00, sgpsirsE10.b1
D041206.1SGP/SIRS/E10 - tracker failuresgpsirs20sE10.a0, sgpsirsE10.00, sgpsirsE10.b1
D060309.1SGP/SIRS/E1 - Reprocess: incorrect calibration coefficients for US (upwelling shortwave)
instrument
sgpsirsE1.00, sgpsirsE1.b1
D060331.2SGP/SIRS/E1 - Intermittantly missing downwelling diffusesgpsirs20sE1.a0, sgpsirsE1.00, sgpsirsE1.b1
D060630.18SGP/SIRS/E10 - Reprocessed: Longwave Calibration errorsgpsirsE10.b1
D060630.9SGP/SIRS/E1 - Reprocessed: Longwave Calibration errorsgpsirsE1.b1


DQRID : D040831.4
Start DateStart TimeEnd DateEnd Time
02/20/2004163004/21/20041425
Subject:
SGP/SIRS/E10 - Reprocess: Incorrect shortwave radiometer calibration coefficients
DataStreams:sgpsirsE10.00, sgpsirsE10.b1
Description:
During the pyrgeometer instrument (PIR) changeout a datalogger program was loaded with 
incorrect calibration coefficients for the shortwave instruments.  The affected measurements 
(instruments) were: downwelling diffuse (8-48), upwelling shortwave (PSP), direct normal 
(NIP) and downwelling shortwave (PSP)

Recalculate irradiances by determining original mV signal and reapplying the correct 
calibration coefficients.  For SGP/SIRS/E10 and each one minute irradiance value perform the 
following calculations by instrument:
DD(corrected) = (DD/107.24)*114.63
US(corrected) = (US/113.19)*117.46
NIP(corrected)= (NIP/120.17)*119.26
DS(corrected) = (DS/118.46)*122.78
Measurements:sgpsirsE10.b1:
  • Shortwave Direct Normal Irradiance, Pyrgeometer, Maxima(short_direct_normal_max)
  • Downwelling Shortwave Hemispheric Irradiance, Pyranometer, Standard Deviation(down_short_diffuse_hemisp_std)
  • Downwelling Shortwave Diffuse Hemispheric Irradiance, Ventilated Pyranometer(down_short_diffuse_hemisp)
  • Upwelling (10 meter) Shortwave Hemispheric Irradiance, Pyranometer, Standard
    Deviation(up_short_hemisp_std)
  • Upwelling (10 meter) Shortwave Hemispheric Irradiance, Pyranometer, Maxima(up_short_hemisp_max)
  • Downwelling Shortwave Diffuse Hemispheric Irradiance, Ventilated Pyranometer,
    Maxima(down_short_diffuse_hemisp_max)
  • Downwelling Shortwave Hemispheric Irradiance, Ventilated Pyranometer, Maxima(down_short_hemisp_max)
  • Upwelling (10 meter) Shortwave Hemispheric Irradiance, Pyranometer(up_short_hemisp)
  • Shortwave Direct Normal Irradiance, Pyrgeometer, Minima(short_direct_normal_min)
  • Down-welling unshaded pyranometer voltage(down_short_hemisp)
  • Downwelling Shortwave Hemispheric Irradiance, Ventilated Pyranometer, Standard
    Deviation(down_short_hemisp_std)
  • Shortwave Direct Normal Irradiance, Pyrgeometer, Standard Deviation(short_direct_normal_std)
  • Downwelling Shortwave Diffuse Hemispheric Irradiance, Ventilated Pyranometer,
    Minima(down_short_diffuse_hemisp_min)
  • Shortwave Direct Normal Irradiance, Pyrgeometer(short_direct_normal)
  • Downwelling Shortwave Hemispheric Irradiance, Ventilated Pyranometer, Minima(down_short_hemisp_min)
  • Upwelling (10 meter) Shortwave Hemispheric Irradiance, Pyranometer, Minima(up_short_hemisp_min)

sgpsirsE10.00:
  • null(Raw data stream - documentation not supported)


Back To Table of Contents

DQRID : D041206.1
Start DateStart TimeEnd DateEnd Time
11/04/2004180001/26/20051600
Subject:
SGP/SIRS/E10 - tracker failure
DataStreams:sgpsirs20sE10.a0, sgpsirsE10.00, sgpsirsE10.b1
Description:
During the night of 11/05-06 2004 the tracker failed at this location. During CM on 12/01, 
power cycling returned the tracker to service. However, tracker was not properly 
tracking in the AM. Tracker failed again sometime near 01/01/2005.  CM on reloaded the tracker 
program and realigned the tracker on 01/26/2005 1600GMT.  It has been working correctly 
since this time.
Measurements:sgpsirsE10.b1:
  • Shortwave Direct Normal Irradiance, Pyrgeometer, Minima(short_direct_normal_min)
  • Shortwave Direct Normal Irradiance, Pyrgeometer, Maxima(short_direct_normal_max)
  • Downwelling Shortwave Hemispheric Irradiance, Pyranometer, Standard Deviation(down_short_diffuse_hemisp_std)
  • Downwelling Shortwave Diffuse Hemispheric Irradiance, Ventilated Pyranometer(down_short_diffuse_hemisp)
  • Shortwave Direct Normal Irradiance, Pyrgeometer, Standard Deviation(short_direct_normal_std)
  • Downwelling Shortwave Diffuse Hemispheric Irradiance, Ventilated Pyranometer,
    Minima(down_short_diffuse_hemisp_min)
  • Shortwave Direct Normal Irradiance, Pyrgeometer(short_direct_normal)
  • Downwelling Shortwave Diffuse Hemispheric Irradiance, Ventilated Pyranometer,
    Maxima(down_short_diffuse_hemisp_max)

sgpsirsE10.00:
  • null(Raw data stream - documentation not supported)

sgpsirs20sE10.a0:
  • Instantaneous Uncorrected Downwelling Shortwave Diffuse, Shaded Pyranometer
    Thermopile Voltage(inst_diffuse)
  • Instantaneous Direct Normal Shortwave Irradiance, Pyheliometer Thermopile
    Voltage(inst_direct_normal)


Back To Table of Contents

DQRID : D060309.1
Start DateStart TimeEnd DateEnd Time
02/21/2006200803/07/20061950
Subject:
SGP/SIRS/E1 - Reprocess: incorrect calibration coefficients for US (upwelling shortwave) 
instrument
DataStreams:sgpsirsE1.00, sgpsirsE1.b1
Description:
During the changeover from 4 to 1 coefficient for the PIRs at SIRS/E1 (PIF) the datalogger 
program was programmed with the wrong calibration coefficient and serial number for the 
US PSP instrument measuring the Upwelling Hemispheric Shortwave radiation. The 
calibration coefficient was 114.43 W/m2/mV (instrument 30618F3) when it should have been 
104.47W/m2/mV (instrument 29618F3)
Measurements:sgpsirsE1.b1:
  • Upwelling (10 meter) Shortwave Hemispheric Irradiance, Pyranometer, Minima(up_short_hemisp_min)
  • Upwelling (10 meter) Shortwave Hemispheric Irradiance, Pyranometer, Standard
    Deviation(up_short_hemisp_std)
  • Upwelling (10 meter) Shortwave Hemispheric Irradiance, Pyranometer(up_short_hemisp)
  • Upwelling (10 meter) Shortwave Hemispheric Irradiance, Pyranometer, Maxima(up_short_hemisp_max)

sgpsirsE1.00:
  • null(Raw data stream - documentation not supported)


Back To Table of Contents

DQRID : D060331.2
Start DateStart TimeEnd DateEnd Time
10/26/2005163004/04/20062005
Subject:
SGP/SIRS/E1 - Intermittantly missing downwelling diffuse
DataStreams:sgpsirs20sE1.a0, sgpsirsE1.00, sgpsirsE1.b1
Description:
Starting on or about 10/26/2005 the downwelling diffuse hemispheric irradiance (Eppley 
8-48) instrument had intermittant missing values. Technicians found a loose wire on the 
instrument connector and repaired it on 4/4/2006. 

Use global shortwave hemispheric (PSP) component - normal incident component (CosZA*NIP) 
to calulate diffuse component.  Comparison of absolute difference between actual and 
computed diffuse component values and diffuse standard deviations > 1-2 W/m2 can help filter 
the noisy diffuse data.  There is no standard method.
Measurements:sgpsirs20sE1.a0:
  • Instantaneous Uncorrected Downwelling Shortwave Diffuse, Shaded Pyranometer
    Thermopile Voltage(inst_diffuse)

sgpsirsE1.b1:
  • Downwelling Shortwave Hemispheric Irradiance, Pyranometer, Standard Deviation(down_short_diffuse_hemisp_std)
  • Downwelling Shortwave Diffuse Hemispheric Irradiance, Ventilated Pyranometer,
    Minima(down_short_diffuse_hemisp_min)
  • Downwelling Shortwave Diffuse Hemispheric Irradiance, Ventilated Pyranometer,
    Maxima(down_short_diffuse_hemisp_max)
  • Downwelling Shortwave Diffuse Hemispheric Irradiance, Ventilated Pyranometer(down_short_diffuse_hemisp)

sgpsirsE1.00:
  • null(Raw data stream - documentation not supported)


Back To Table of Contents

DQRID : D060630.18
Start DateStart TimeEnd DateEnd Time
02/20/2004173002/07/20062130
Subject:
SGP/SIRS/E10 - Reprocessed: Longwave Calibration error
DataStreams:sgpsirsE10.b1
Description:
Modified pyrgeometer calibration procedures were implemented beginning in February 2004. 
These modified procedures introduced a calibration bias in the longwave data. The previous 
procedures were re-implemented at all sites between December 2005 and February 2006 to 
restore proper calibrations.                                                               
              
The data collected while the incorrect procedures were in place have been reprocessed to 
remove the calibration bias.  The reprocessed 60 second averaged data are based on 3 
instantaneous 20 second data records rather than on 60 1 second instantaneous data records. 
Still, these data are considered far superior to the originally processed data. The 
reprocessed data were archived in August 2006.
Measurements:sgpsirsE10.b1:
  • Upwelling Longwave Hemispheric Net Infrared(up_long_netir)
  • Upwelling (10 meter) Longwave Hemispheric Irradiance, Pyrgeometer(up_long_hemisp)
  • Downwelling Longwave Hemispheric Irradiance, Shaded Pyrgeometer(down_long_hemisp_shaded)
  • Downwelling Longwave Hemispheric Net Infrared(down_long_netir)


Back To Table of Contents

DQRID : D060630.9
Start DateStart TimeEnd DateEnd Time
02/10/2004205502/21/20062007
Subject:
SGP/SIRS/E1 - Reprocessed: Longwave Calibration error
DataStreams:sgpsirsE1.b1
Description:
Modified pyrgeometer calibration procedures were implemented beginning in February 2004. 
These modified procedures introduced a calibration bias in the longwave data. The previous 
procedures were re-implemented at all sites between December 2005 and February 2006 to 
restore proper calibrations.	

The data collected while the incorrect procedures were in place have been reprocessed to 
remove the calibration bias.  The reprocessed 60 second averaged data are based on 3 
instantaneous 20 second data records rather than on 60 1 second instantaneous data records.  
Still, these data are considered far superior to the originally processed data.  The 
reprocessed data were archived in October 2006.
Measurements:sgpsirsE1.b1:
  • Upwelling (10 meter) Longwave Hemispheric Irradiance, Pyrgeometer(up_long_hemisp)
  • Downwelling Longwave Hemispheric Irradiance, Shaded Pyrgeometer(down_long_hemisp_shaded)
  • Upwelling Longwave Hemispheric Net Infrared(up_long_netir)
  • Downwelling Longwave Hemispheric Net Infrared(down_long_netir)


Back To Table of Contents



END OF DATA