Data Quality Reports for Session: 115293 User: sherman Completed: 10/29/2008


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D951005.4SGP/MWR/C1 - Valid LWP > 1mm excluded from 5 min avgssgp5mwravgC1.c1
D960405.1SGP/MWR/C1 - Loss of thermal stabilizationsgp1mwravgC1.c1, sgp5mwravgC1.c1, sgpmwrlosC1.a1, sgpmwrlosC1.b1
D960422.1SGP/MWR/C1 - Radio Frequency Interference during IOPsgp5mwravgC1.c1, sgpmwrlosC1.a1, sgpmwrlosC1.b1
D961120.1SGP/MWR/B1/B4/B5/B6/C1 - Thermal Stabilization Adjustmentsgp1mwravgC1.c1, sgp5mwravgB1.c1, sgp5mwravgB4.c1, sgp5mwravgB5.c1, sgp5mwravgB6.c1,
sgp5mwravgC1.c1, sgpmwrlosB1.a0, sgpmwrlosB1.a1, sgpmwrlosB4.a0, sgpmwrlosB4.a1,
sgpmwrlosB5.a0, sgpmwrlosB5.a1, sgpmwrlosB6.a0, sgpmwrlosB6.a1, sgpmwrlosC1.a1, sgpmwrlosC1.b1


DQRID : D951005.4
Start DateStart TimeEnd DateEnd Time
10/09/1993000510/12/19952359
Subject:
SGP/MWR/C1 - Valid LWP > 1mm excluded from 5 min avgs
DataStreams:sgp5mwravgC1.c1
Description:
The limit of maximum valid liquid water path was set at 1 mm.  Although
this limit was selected 'conservatively' so as to definitely flag
precipitation-contaminated data in the 20-second (sgpmwrlos) files,
the effect has been to exclude valid liquid water paths greater than 1
mm from the 5-minute averages (sgp5mwravg).

The maximum limits for precipitable water vapor (PWV) and liquid water
path (LWP) have been removed, and the averaging algorithm instead
excludes data on the basis of the brightness temperature flags.  These
flags are set below a minimum of 2.75 K (cosmic background) and above
a maximum of 100 K (precipitation).
Measurements:sgp5mwravgC1.c1:
  • Averaged total liquid water along LOS path(liq)
  • Standard deviation about the mean for the total liquid water amount(liq_sdev)


Back To Table of Contents

DQRID : D960405.1
Start DateStart TimeEnd DateEnd Time
08/19/1995000008/20/19952359
08/26/1995000009/04/19952359
07/01/1996182507/23/19962300
Subject:
SGP/MWR/C1 - Loss of thermal stabilization
DataStreams:sgp1mwravgC1.c1, sgp5mwravgC1.c1, sgpmwrlosC1.a1, sgpmwrlosC1.b1
Description:
Periodically during August and September 1995 all microwave radiometers
at the SGP CART generated error messages in the Site Operations Log
like:

  Time: Sat Aug 19 18:41:20 1995
  MWRLOS.C1, tkxc: Value above Maximum.

This indicates that the temperature of the microwave hardware
(specifically, the cross-coupler or "xc") exceeded its controlled
temperature (47-52 deg C) at which point it was no longer thermally
stabilized and the gain was uncontrolled.  During these periods which
typically last about 8 hours from about local noon until about sunset
the data behave anomalously and should be considered invalid.

Specifically the precipitable water vapor increases and the liquid
water path decreases (and becomes SIGNIFICANTLY NEGATIVE (-0.1 mm) on
clear sky days).  The RMS noise level in the data also increases
sharply.  The 'Tkxc' field appears ONLY in the a0-level data and does
NOT appear in either the a1 (mwrlos) or c1 (mwr5avg) files.  Therefore
THESE ANOMALOUS VALUES HAVE BEEN INCLUDED IN THE 5-MINUTE AVERAGES.

The microwave hardware is thermally stabilized to about +/- 0.1 deg C
by resistive heating.  When the internal temperature rises above the
set point the thermal stabilization of the instrument gain is lost.
>From an examination of the component temperature data it appears that
increasing the set point temperature to about 55 deg C (328 K) would
prevent a re-ocurrance of this problem at the SGP.  The manufacturer,
Radiometrics, concurs that raising the set point will fix this problem
and will not cause other problems.

I will have to carefully examine the MCTEX data to determine whether
this will be a problem for the TWP.  The manufacturer and I had
discussed this possibility prior to building the TWP MWRs (S/N 015,
016, and 017) and those instruments have set points above 50 deg C.
Note that MWR 018 has a set point near 52 deg C (like the TWP models)
but it still experienced a few loss-of-stabilization events.

Note that the instruments with the lowest set points had the most
loss-of-stabilization events.
Measurements:sgp5mwravgC1.c1:
  • 31.4 GHz sky brightness temperature(31tbsky)
  • Averaged total liquid water along LOS path(liq)
  • MWR column precipitable water vapor(vap)
  • 23.8 GHz sky brightness temperature(23tbsky)

sgpmwrlosC1.b1:
  • Sky brightness temperature at 31.4 GHz(tbsky31)
  • Averaged total liquid water along LOS path(liq)
  • MWR column precipitable water vapor(vap)
  • Sky brightness temperature at 23.8 GHz(tbsky23)

sgp1mwravgC1.c1:
  • 23.8 GHz sky brightness temperature(23tbsky)
  • Averaged total liquid water along LOS path(liq)
  • MWR column precipitable water vapor(vap)
  • 31.4 GHz sky brightness temperature(31tbsky)

sgpmwrlosC1.a1:
  • MWR column precipitable water vapor(vap)
  • Sky brightness temperature at 23.8 GHz(tbsky23)
  • Sky brightness temperature at 31.4 GHz(tbsky31)
  • Averaged total liquid water along LOS path(liq)


Back To Table of Contents

DQRID : D960422.1
Start DateStart TimeEnd DateEnd Time
04/09/1996133704/09/19961834
04/10/1996062504/10/19961823
04/11/1996114904/11/19961649
04/12/1996091704/12/19961858
04/13/1996060504/13/19961801
Subject:
SGP/MWR/C1 - Radio Frequency Interference during IOP
DataStreams:sgp5mwravgC1.c1, sgpmwrlosC1.a1, sgpmwrlosC1.b1
Description:
During the specified times a strong, continuous signal was 
measured by the 31.4 GHz of the MWR.  The signal was present
in all 31.4 GHz measurements including the sky measurement,
the internal reference target measurement, and the measurement
of the internal noise injection source from which the
instantaneous instrument gain is computed.

The source of the interference has not yet been identified.

Because the gain is computed using the difference of the
noise injection and target measurements, and because the
sky brightness temperature is computed relative to the
internal target temperature, the data appear anomalous
only for a period of an hour after the interference starts
and ends.  This is due to the low pass filter applied to
the instantaneous gain.  However the data should be
considered invalid or at least questionable during the
entire period for which the interference was present.
Measurements:sgp5mwravgC1.c1:
  • Flag indicating where the initial surface water measurements are from: 0-> SMOS,
    1-> AERI(water_flag)
  • Fraction of data in averaging interval with water on Teflon window(water_flag_fraction)
  • 23.8 GHz sky brightness temperature(23tbsky)
  • Standard deviation about the mean for the IR brightness temperature(ir_temp_sdev)
  • Number of data points averaged out of 15(number_obs_averaged)
  • base time(base_time)
  • Standard deviation about the mean for the 31.4 GHz sky brightness temperature(tbsky31_sdev)
  • Standard deviation about the mean for the total water vapor amount(vap_sdev)
  • Averaged total liquid water along LOS path(liq)
  • IR Brightness Temperature(ir_temp)
  • Probability of level change in ratio of averaged brightness temps(prob_level_change)
  • Standard deviation about the mean for the 23.8 GHz sky brightness temperature(tbsky23_sdev)
  • lon(lon)
  • Probability of slope change in ratio of averaged brightness temps(prob_slope_change)
  • Number of data points averaged for 23tbsky, 31tbsky, vap & liq(num_obs)
  • Probability of outlier in ratio of averaged brightness temps(prob_outlier)
  • Sky brightness temperature at 23.8 GHz(tbsky23)
  • Sky brightness temperature at 31.4 GHz(tbsky31)
  • Number of points included in the ir_temp ensemble(num_obs_irt)
  • 31.4 GHz sky brightness temperature(31tbsky)
  • Standard deviation about the mean for the total liquid water amount(liq_sdev)
  • Dummy altitude for Zeb(alt)
  • MWR column precipitable water vapor(vap)
  • Time offset of tweaks from base_time(time_offset)
  • lat(lat)

sgpmwrlosC1.b1:
  • 31.4 GHz sky signal(sky31)
  • Water on Teflon window (1=WET, 0=DRY)(wet_window)
  • Dummy altitude for Zeb(alt)
  • 31.4 GHz blac2body+noise injection signal(bbn31)
  • Noise injection temp at nominal temperature at 31.4 GHz(tnd_nom31)
  • 23.8 GHz sky signal(sky23)
  • Sky brightness temperature at 31.4 GHz(tbsky31)
  • lon(lon)
  • Noise injection temp at 31.4 GHz adjusted to tkbb(tnd31)
  • Averaged total liquid water along LOS path(liq)
  • Noise injection temp at nominal temperature at 23.8 GHz(tnd_nom23)
  • 31.4 GHz blackbody(bb31)
  • Temperature correction coefficient at 31.4 GHz(tc31)
  • Blackbody kinetic temperature(tkbb)
  • Sky Infra-Red Temperature(sky_ir_temp)
  • MWR column precipitable water vapor(vap)
  • Ambient temperature(tkair)
  • 23.8 GHz Blackbody signal(bb23)
  • Sky brightness temperature at 23.8 GHz(tbsky23)
  • Mixer kinetic (physical) temperature(tkxc)
  • Time offset of tweaks from base_time(time_offset)
  • base time(base_time)
  • (tknd)
  • Noise injection temp at 23.8 GHz adjusted to tkbb(tnd23)
  • 23.8 GHz blackbody+noise injection signal(bbn23)
  • Temperature correction coefficient at 23.8 GHz(tc23)
  • lat(lat)

sgpmwrlosC1.a1:
  • 31.4 GHz blac2body+noise injection signal(bbn31)
  • Noise injection temp at 31.4 GHz adjusted to tkbb(tnd31)
  • Sky brightness temperature at 31.4 GHz(tbsky31)
  • 23.8 GHz sky signal(sky23)
  • Temperature correction coefficient at 23.8 GHz(tc23)
  • MWR column precipitable water vapor(vap)
  • (tknd)
  • Sky brightness temperature at 23.8 GHz(tbsky23)
  • Ambient temperature(tkair)
  • Noise injection temp at nominal temperature at 23.8 GHz(tnd_nom23)
  • 23.8 GHz Blackbody signal(bb23)
  • Mixer kinetic (physical) temperature(tkxc)
  • Water on Teflon window (1=WET, 0=DRY)(wet_window)
  • 31.4 GHz sky signal(sky31)
  • Dummy altitude for Zeb(alt)
  • lon(lon)
  • Temperature correction coefficient at 31.4 GHz(tc31)
  • 31.4 GHz blackbody(bb31)
  • Blackbody kinetic temperature(tkbb)
  • lat(lat)
  • Sky Infra-Red Temperature(sky_ir_temp)
  • Noise injection temp at 23.8 GHz adjusted to tkbb(tnd23)
  • Noise injection temp at nominal temperature at 31.4 GHz(tnd_nom31)
  • Averaged total liquid water along LOS path(liq)
  • 23.8 GHz blackbody+noise injection signal(bbn23)
  • base time(base_time)
  • Time offset of tweaks from base_time(time_offset)


Back To Table of Contents

DQRID : D961120.1
Start DateStart TimeEnd DateEnd Time
08/01/1996000008/31/19962359
Subject:
SGP/MWR/B1/B4/B5/B6/C1 - Thermal Stabilization Adjustment
DataStreams:sgp1mwravgC1.c1, sgp5mwravgB1.c1, sgp5mwravgB4.c1, sgp5mwravgB5.c1, sgp5mwravgB6.c1,
sgp5mwravgC1.c1, sgpmwrlosB1.a0, sgpmwrlosB1.a1, sgpmwrlosB4.a0, sgpmwrlosB4.a1,
sgpmwrlosB5.a0, sgpmwrlosB5.a1, sgpmwrlosB6.a0, sgpmwrlosB6.a1, sgpmwrlosC1.a1, sgpmwrlosC1.b1
Description:
In order to correct a thermal stabilization problem identified earlier
I adjusted the thermal set point of the microwave radiometers at the
SGP upward from 48-50 deg C to 55 deg C in early August 1996 according
to the schedule given below.

B6    5 August 1996
C1    6 August 1996
B1    7 August 1996
B5    8 August 1996

Subsequent to making this adjustment the MWRs were put in TIP mode to
check on whether the change in set point temperature affected their
calibration.  Because clear sky conditions were quite intermittent, it
is difficult to determine whether the substantial variability in the
tip data were attributable to the change in thermal set point.  The
instrument calibration was not altered in August.

Tip data were again collected with these instruments in September prior
to the beginning and at the close of the Water Vapor IOP.  For example,
the calibration of the instrument at the central facility (S/N 10)
derived from the September data was essentially the same as that
derived from calibration data acquired in February 1996.  Although this
would lead one to believe that altering the thermal set point did not
affect the instrument calibration, it may be that some transient effect
was induced.

In comparing soundings launched from the central facility with the
microwave radiometer there, I noticed that those sondes calibrated in
June 1996 consistently reported lower integrated water vapor than the
radiometer in July and September (during the IOP) but were in better
agreement with the radiometer for the two weeks period immediately
after the set point was adjusted.  I suspect that adjusting the thermal
set point may have temporarily increased the radiometer gain
(kelvins/volt) thereby lowering the measured brightness temperature and
the retrieved integrated water vapor.

It is not clear why a temporary change in gain should occur or even
whether it did.  But users of the data should be aware that the data
from the microwave radiometers at the SGP may be anomalous during
August 1996.
Measurements:sgpmwrlosB5.a1:
  • MWR column precipitable water vapor(vap)
  • 31.4 GHz sky brightness temperature(31tbsky)
  • Averaged total liquid water along LOS path(liq)
  • 23.8 GHz sky brightness temperature(23tbsky)

sgp5mwravgC1.c1:
  • 23.8 GHz sky brightness temperature(23tbsky)
  • Averaged total liquid water along LOS path(liq)
  • 31.4 GHz sky brightness temperature(31tbsky)
  • MWR column precipitable water vapor(vap)

sgp5mwravgB6.c1:
  • 23.8 GHz sky brightness temperature(23tbsky)
  • 31.4 GHz sky brightness temperature(31tbsky)
  • Averaged total liquid water along LOS path(liq)
  • MWR column precipitable water vapor(vap)

sgpmwrlosB4.a0:
  • 23.8 GHz sky brightness temperature(23tbsky)
  • Averaged total liquid water along LOS path(liq)
  • MWR column precipitable water vapor(vap)
  • 31.4 GHz sky brightness temperature(31tbsky)

sgpmwrlosB6.a0:
  • Averaged total liquid water along LOS path(liq)
  • 23.8 GHz sky brightness temperature(23tbsky)
  • MWR column precipitable water vapor(vap)
  • 31.4 GHz sky brightness temperature(31tbsky)

sgpmwrlosC1.b1:
  • Sky brightness temperature at 31.4 GHz(tbsky31)
  • Averaged total liquid water along LOS path(liq)
  • MWR column precipitable water vapor(vap)
  • Sky brightness temperature at 23.8 GHz(tbsky23)

sgpmwrlosB1.a0:
  • Averaged total liquid water along LOS path(liq)
  • 23.8 GHz sky brightness temperature(23tbsky)
  • MWR column precipitable water vapor(vap)
  • 31.4 GHz sky brightness temperature(31tbsky)

sgp1mwravgC1.c1:
  • 23.8 GHz sky brightness temperature(23tbsky)
  • MWR column precipitable water vapor(vap)
  • 31.4 GHz sky brightness temperature(31tbsky)
  • Averaged total liquid water along LOS path(liq)

sgpmwrlosC1.a1:
  • Sky brightness temperature at 31.4 GHz(tbsky31)
  • MWR column precipitable water vapor(vap)
  • Sky brightness temperature at 23.8 GHz(tbsky23)
  • Averaged total liquid water along LOS path(liq)

sgpmwrlosB4.a1:
  • Averaged total liquid water along LOS path(liq)
  • 31.4 GHz sky brightness temperature(31tbsky)
  • 23.8 GHz sky brightness temperature(23tbsky)
  • MWR column precipitable water vapor(vap)

sgpmwrlosB1.a1:
  • MWR column precipitable water vapor(vap)
  • 31.4 GHz sky brightness temperature(31tbsky)
  • 23.8 GHz sky brightness temperature(23tbsky)
  • Averaged total liquid water along LOS path(liq)

sgp5mwravgB1.c1:
  • MWR column precipitable water vapor(vap)
  • 31.4 GHz sky brightness temperature(31tbsky)
  • 23.8 GHz sky brightness temperature(23tbsky)
  • Averaged total liquid water along LOS path(liq)

sgp5mwravgB5.c1:
  • Averaged total liquid water along LOS path(liq)
  • 31.4 GHz sky brightness temperature(31tbsky)
  • 23.8 GHz sky brightness temperature(23tbsky)
  • MWR column precipitable water vapor(vap)

sgpmwrlosB5.a0:
  • 23.8 GHz sky brightness temperature(23tbsky)
  • Averaged total liquid water along LOS path(liq)
  • 31.4 GHz sky brightness temperature(31tbsky)
  • MWR column precipitable water vapor(vap)

sgp5mwravgB4.c1:
  • MWR column precipitable water vapor(vap)
  • Averaged total liquid water along LOS path(liq)
  • 23.8 GHz sky brightness temperature(23tbsky)
  • 31.4 GHz sky brightness temperature(31tbsky)

sgpmwrlosB6.a1:
  • Averaged total liquid water along LOS path(liq)
  • MWR column precipitable water vapor(vap)
  • 31.4 GHz sky brightness temperature(31tbsky)
  • 23.8 GHz sky brightness temperature(23tbsky)


Back To Table of Contents