Data Quality Reports for Session: 112984 User: sherman Completed: 07/08/2008


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D040428.1TWP/SMET/C1 - Poor Performing Sensortwpsmet60sC1.b1
D050210.1TWP/SMET/C3 - Data non-representativetwpsmet60sC3.b1
D050301.1TWP/SMET/C2 - Instrument failuretwpsmet60sC2.b1
D050322.2TWP/SMET/C2 - Upper wind sensor failuretwpsmet60sC2.b1
D060817.3TWP/SMET/C1 - Reprocess: Barometric Data Changed from hPa to kPatwpsmet60sC1.b1
D060818.2TWP/SMET/C2 - Reprocess: Barometric Data Changed from hPa to kPatwpsmet60sC2.b1
D060818.3TWP/SMET/C3 - Reprocess: Barometric Data Changed from hPa to kPatwpsmet60sC3.b1
D061011.2TWP/SMET/C1 - Reprocess: Tipping bucket rain gauge addedtwpsmet60sC1.b1
D061011.3TWP/SMET/C2 - Reprocess: Tipping bucket rain gauge addedtwpsmet60sC2.b1
D061011.4TWP/SMET/C3 - Reprocess: Tipping bucket rain gauge addedtwpsmet60sC3.b1


DQRID : D040428.1
Start DateStart TimeEnd DateEnd Time
04/23/2004000001/19/20051530
Subject:
TWP/SMET/C1 - Poor Performing Sensor
DataStreams:twpsmet60sC1.b1
Description:
On 4/23/2004 condensation was found inside the target area of the ORG lens. A spare was 
sent and installed but did not solve the problem of high background voltage values causing 
rainrate values to be recorded during no rainfall.  Values range anywhere from 0.06 to 
0.12 mm/hr.  

A new Optical Rain Gage was installed on 01/19/2005 @ 13:30 GMT alleviating the high 
background voltage values that lead to consistent rainfall rates of around 0.11 to 0.15 mm/hr 
on a consistent basis.  

The formula used to calculate rainfall rates from the new Optical Rain Gage is:  RR 
(mm/hr) = 25(V^1.87) - 0.15.

Older model formula = 20(V^2) - 0.05

The two formulas result in comparable data.
Measurements:twpsmet60sC1.b1:
  • Precipitation mean(precip_mean)
  • Precipitation maximum(precip_max)
  • Precipitation standard deviation(precip_sd)
  • precipitation minimum(precip_min)


Back To Table of Contents

DQRID : D050210.1
Start DateStart TimeEnd DateEnd Time
02/09/2005231002/09/20052320
Subject:
TWP/SMET/C3 - Data non-representative
DataStreams:twpsmet60sC3.b1
Description:
Tower mast was lowered for inspection.  Data during this time is non-representative.
Measurements:twpsmet60sC3.b1:
  • Precipitation maximum(precip_max)
  • Wind #2 speed arithmetic average(wind2_spd_arith_avg)
  • Wind #1 speed minimum(wind1_spd_min)
  • Wind #2 speed maximum(wind2_spd_max)
  • precipitation minimum(precip_min)
  • Wind #1 direction standard deviation(wind1_dir_sd)
  • Mean Air Temperature or Hardware Error(temp_mean)
  • Wind #1 speed maximum(wind1_spd_max)
  • Wind #2 speed minimum(wind2_spd_min)
  • Temperature maximum(temp_max)
  • Vapor pressure mean(vappress_mean)
  • Barometric Pressure(atmos_pressure)
  • Vapor pressure standard deviation(vappress_sd)
  • Mean Relative Humidity(relh_mean)
  • Relative humidity maximum(relh_max)
  • Wind #1 direction vector average(wind1_dir_vec_avg)
  • Wind #1 speed standard deviation(wind1_spd_sd)
  • Wind #1 speed vector average(wind1_spd_vec_avg)
  • Wind #2 direction vector average(wind2_dir_vec_avg)
  • Std Dev of Relative Humidity or Hardware Error Code(relh_sd)
  • Relative humidity minimum(relh_min)
  • Precipitation mean(precip_mean)
  • Wind #2 speed vector average(wind2_spd_vec_avg)
  • Temperature minimum(temp_min)
  • Wind #2 speed maximum gust(wind2_spd_max_gust)
  • Precipitation standard deviation(precip_sd)
  • Wind #1 speed maximum gust(wind1_spd_max_gust)
  • Wind #1 speed arithmetic average(wind1_spd_arith_avg)
  • Wind #2 direction standard deviation(wind2_dir_sd)
  • Wind #2 speed standard deviation(wind2_spd_sd)
  • Std Dev of Air Temperature(temp_sd)


Back To Table of Contents

DQRID : D050301.1
Start DateStart TimeEnd DateEnd Time
02/12/2005195503/03/20050430
Subject:
TWP/SMET/C2 - Instrument failure
DataStreams:twpsmet60sC2.b1
Description:
Upper wind sensor failed. Wind direction was reported at a near constant value of 69 
degrees and was significantly different than the lower wind sensor's direction values. Sensor 
replaced.
Measurements:twpsmet60sC2.b1:
  • Wind #1 direction standard deviation(wind1_dir_sd)
  • Wind #1 direction vector average(wind1_dir_vec_avg)


Back To Table of Contents

DQRID : D050322.2
Start DateStart TimeEnd DateEnd Time
03/09/2005230004/17/20050332
Subject:
TWP/SMET/C2 - Upper wind sensor failure
DataStreams:twpsmet60sC2.b1
Description:
After replacement on 03/03/2005 the upper wind sensor began reporting erroneous values 
again on 03/09/2005 becoming very apparent after 03/17/2005.  Wind speed data appears 
reasonable but the wind direction data do not agree well with the lower wind sensor.
Measurements:twpsmet60sC2.b1:
  • Wind #1 direction standard deviation(wind1_dir_sd)
  • Wind #1 direction vector average(wind1_dir_vec_avg)


Back To Table of Contents

DQRID : D060817.3
Start DateStart TimeEnd DateEnd Time
10/09/1996000007/13/20062225
Subject:
TWP/SMET/C1 - Reprocess: Barometric Data Changed from hPa to kPa
DataStreams:twpsmet60sC1.b1
Description:
Barometric pressure data was converted from hPa to kPa in order to standardize the 
measurement units among ARM sites and to conform to accepted standard units determined by the 
scientific community.
Measurements:twpsmet60sC1.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D060818.2
Start DateStart TimeEnd DateEnd Time
10/21/1998000007/13/20062232
Subject:
TWP/SMET/C2 - Reprocess: Barometric Data Changed from hPa to kPa
DataStreams:twpsmet60sC2.b1
Description:
Barometric pressure data was converted from hPa to kPa in order to standardize the 
measurement units among ARM sites and to conform to accepted standard units determined by the 
scientific community.
Measurements:twpsmet60sC2.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D060818.3
Start DateStart TimeEnd DateEnd Time
12/02/2003000007/13/20062219
Subject:
TWP/SMET/C3 - Reprocess: Barometric Data Changed from hPa to kPa
DataStreams:twpsmet60sC3.b1
Description:
Barometric pressure data was converted from hPa to kPa in order to standardize the 
measurement units among ARM sites and to conform to accepted standard units determined by the 
scientific community.
Measurements:twpsmet60sC3.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D061011.2
Start DateStart TimeEnd DateEnd Time
10/09/1996000010/17/20060000
Subject:
TWP/SMET/C1 - Reprocess: Tipping bucket rain gauge added
DataStreams:twpsmet60sC1.b1
Description:
A tipping bucket rain gauge was added to the TWP.C1 SMET suite of instruments on 20061017. 
 Effective 20060926, two new variables (count and rain amount) were added to the end of 
the twpsmet60sC1.b1 datastream.  Between 9/26 and 10/17, the data for these two variables 
are filled with zeros.  Users should not use the data during this period as the zeros 
are not representative of the rain fall at the site.  When reprocessing of this datastream 
occurs these variables will be added for the 19961009-20060926 and data from 
19961009-20061017 will be filled with -9999 (missing).
Measurements:twpsmet60sC1.b1:
  • base time(base_time)


Back To Table of Contents

DQRID : D061011.3
Start DateStart TimeEnd DateEnd Time
10/21/1998000011/29/20062014
Subject:
TWP/SMET/C2 - Reprocess: Tipping bucket rain gauge added
DataStreams:twpsmet60sC2.b1
Description:
A tipping bucket rain gauge was added to the TWP.C2 SMET suite of instruments on 20061129. 
Effective 20060926, two new variables (count and rain amount) were added to the end of 
the twpsmet60sC2.b1 datastream.  Between 9/26 and 11/29, the data for these two variables 
are filled with zeros.  Users should not use the data during this period as the zeros are 
not representative of the rain fall at the site.  When reprocessing of this datastream 
occurs these variables will be added for the 19981021-20060926 and data from 
19981021-20061129 will be filled with -9999 (missing).
Measurements:twpsmet60sC2.b1:
  • base time(base_time)


Back To Table of Contents

DQRID : D061011.4
Start DateStart TimeEnd DateEnd Time
03/12/2002000009/26/20061435
Subject:
TWP/SMET/C3 - Reprocess: Tipping bucket rain gauge added
DataStreams:twpsmet60sC3.b1
Description:
A tipping bucket rain gauge was added to the SMET suite of instruments effective 20060926. 
 Two new variables (count and rain amount) were added at the end of the twpsmet60sC1.b1 
datastream.  When reprocessing of this datastream occurs these variables will be added 
with -9999 (missing) as the value for dates prior to gauge installation.
Measurements:twpsmet60sC3.b1:
  • base time(base_time)


Back To Table of Contents



END OF DATA