Data Quality Reports for Session: 111007 User: gaustad Completed: 03/14/2008


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D970111.1Incorrect surface temperaturesgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D970318.2Questionable RHsgpsondewrpnC1.a1
D970507.2Jump in pressure valuesgpsondewrpnC1.a1
D970624.2Incorrect surface valuessgpsondewrpnC1.a1
D970625.1Bad sounding file CF 970622:0228sgpsondewrpnC1.a1
D970709.1Bad pressure values CF sounding 970704:0525sgpsondewrpnC1.a1
D970923.2Pressure jump at launchsgpsondewrpnC1.a1
D980126.1Incorrect radiosonde serial numberssgpsondewrpnB1.a0, sgpsondewrpnB1.a1, sgpsondewrpnB4.a0, sgpsondewrpnB4.a1,
sgpsondewrpnB5.a0, sgpsondewrpnB5.a1, sgpsondewrpnB6.a0, sgpsondewrpnB6.a1, sgpsondewrpnC1.a0,
sgpsondewrpnC1.a1


DQRID : D970111.1
Start DateStart TimeEnd DateEnd Time
01/10/1997173001/10/19971730
Subject:
Incorrect surface temperature
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
DQR No:                               Platform: sgpsondeC1

Subject: Incorrect surface temperature: sounding C1 01/10/97:1730

Date Submitted:  1/11/97
Submitted By:                         _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      _X_  Other - Site Ops
 
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement: sgpsondewrpnC1/all
    What level data: (raw,a0,a1,b1,c1 etc):

    What location was the data collected at:  CF
 
    Period of time in question
        Begin Date  01/10/97   Time 17:30      (GMT)
        End Date               Time            (GMT)

 Data should be labeled:
 ____  questionable                      ___  All data fields affected
 _X__  incorrect                         _X_  Only some data fields affected
 ___  wrong calibration
 ___  others 
 
 Discussion of Problem:

The site operator noted that the surface temperature for the subject sounding
was entered incorrectly.  The value entered was -3.3 degC; the correct value
should be -6.3 degC.  This is a fairly benign error, only the surface values
will be affected.
 
Other observations/measurements impacted by this problem:

None

Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Flag data.
Measurements:sgpsondewrpnC1.a0:
  • Retrieved pressure profile(pres)
  • Relative humidity inside the instrument enclosure(rh)
  • lat(lat)
  • Mean Wind Speed(wspd)
  • Ascent Rate(asc)
  • Dummy altitude for Zeb(alt)
  • Dry bulb temperature(tdry)
  • lon(lon)
  • Wind Status(wstat)
  • Wind Direction(deg)
  • Surface dew point temperature(dp)
  • Time offset of tweaks from base_time(time_offset)
  • base time(base_time)

sgpsondewrpnC1.a1:
  • lon(lon)
  • V-component(v_wind)
  • Ascent Rate(asc)
  • Time offset of tweaks from base_time(time_offset)
  • Wind Status(wstat)
  • Relative humidity inside the instrument enclosure(rh)
  • Dummy altitude for Zeb(alt)
  • Wind Direction(deg)
  • Retrieved pressure profile(pres)
  • Dry bulb temperature(tdry)
  • U-component(u_wind)
  • base time(base_time)
  • Surface dew point temperature(dp)
  • Mean Wind Speed(wspd)
  • lat(lat)


Back To Table of Contents

DQRID : D970318.2
Start DateStart TimeEnd DateEnd Time
03/07/1997142703/07/19971427
Subject:
Questionable RH
DataStreams:sgpsondewrpnC1.a1
Description:
DQR No:                               Platform: sgpsondeC1

Subject: Questionable RH: sounding C1 03/07/97:1427

Date Submitted:  3/18/97
Submitted By:                         _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other - Site Ops
 
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement: sgpsondewrpnC1.A1/all
    What level data: (raw,a0,a1,b1,c1 etc):

    What location was the data collected at:  CF
 
    Period of time in question
        Begin Date  03/07/97   Time 14:27      (GMT)
        End Date               Time            (GMT)

 Data should be labeled:
 _X__  questionable                      _?_  All data fields affected
 _X__  incorrect                         _X_  Only some data fields affected
 _?_  wrong calibration
 ___  others 
 
 Discussion of Problem:

David Cook pointed out that the RH values for the subject sounding disagree
substantially with values reported at the 60m tower.  Review of the sounding
data shows saturation (100%) values reported at the surface and during
most of the sounding.  The site ops log shows RH values of between 68% (1400) 
and 52% (1500) at the surface.  Surface temperature (8.4) and pressure (983.0)
obtained from the sonde are not substantially different from the surface
observations (7.8/10.8) and (982.7/982.4) at 1400 and 1500 respectively, so
it is unlikely that an incorrect calibration tape was used for the sonde.
I think the conclusion must be that the RH sensor on this sonde was bad.

As an operational issue, this sonde should have been rejected by site ops
because the surface RH value of 100% is more than 7% different than the surface
value obtained from an independent reference instrument.  I will check the 
procedures that I have provided to site ops to be sure that I included this
criterion.  
 
Other observations/measurements impacted by this problem:

None

Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Flag data.
Measurements:sgpsondewrpnC1.a1:
  • Wind Status(wstat)
  • lon(lon)
  • Relative humidity inside the instrument enclosure(rh)
  • V-component(v_wind)
  • Ascent Rate(asc)
  • Dummy altitude for Zeb(alt)
  • Time offset of tweaks from base_time(time_offset)
  • Wind Direction(deg)
  • Retrieved pressure profile(pres)
  • Dry bulb temperature(tdry)
  • U-component(u_wind)
  • base time(base_time)
  • Surface dew point temperature(dp)
  • Mean Wind Speed(wspd)
  • lat(lat)


Back To Table of Contents

DQRID : D970507.2
Start DateStart TimeEnd DateEnd Time
05/05/1997173205/05/19971732
Subject:
Jump in pressure value
DataStreams:sgpsondewrpnC1.a1
Description:
DQR No:                               Platform:  sgpsondeC1

Subject:        Jump in pressure value C1 sounding 970505.1732

Date Submitted: 5/06/97
Submitted By:   Barry Lesht           _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________
 
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement: sgpsondewrpnc1/ (alt, asc, press)
    What level data: (raw,a0,a1,b1,c1 etc): all

    What location was the data collected at: SGP/CF
 
    Period of time in question
        Begin Date  5/05/97    Time   17:32    (GMT)
        End Date               Time            (GMT)

 Data should be labeled:
 ___  questionable                      _X_  All data fields affected
 _X_  incorrect                         ___  Only some data fields affected
 ___  wrong calibration
 ___  others 
 
 Discussion of Problem:

The first pressure value reported by the radiosonde (t = 2 sec) is
974.9.  The surface pressure value was 980.9 hPa.  This difference
is somewhat greater than the expected (normal) change and may mean that
either the pressure sensor was jarred during launch or the system 
mis-identified the actual launch start time.  Further clarification requires 
analysis of the raw data which will take some time.  The altitude values 
for this sounding will be incorrect.  The ascent rate values during the 
first 30 seconds also will be wrong.  Because the system will reject 
samples with out of bound ascent rates (i.e., during the first 30 seconds), 
the temperature and rh values also will be incorrect (result of 
interpolation).  Relative height values after 30 seconds should be okay.

 
Other observations/measurements impacted by this problem:


Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Flag data.
Measurements:sgpsondewrpnC1.a1:
  • Wind Status(wstat)
  • lon(lon)
  • Relative humidity inside the instrument enclosure(rh)
  • V-component(v_wind)
  • Ascent Rate(asc)
  • Dummy altitude for Zeb(alt)
  • Time offset of tweaks from base_time(time_offset)
  • Wind Direction(deg)
  • Retrieved pressure profile(pres)
  • Dry bulb temperature(tdry)
  • U-component(u_wind)
  • base time(base_time)
  • Surface dew point temperature(dp)
  • Mean Wind Speed(wspd)
  • lat(lat)


Back To Table of Contents

DQRID : D970624.2
Start DateStart TimeEnd DateEnd Time
06/21/1997202706/21/19972027
Subject:
Incorrect surface values
DataStreams:sgpsondewrpnC1.a1
Description:
DQR No:                               Platform:  sgpsondeC1

Subject:        Incorrect surface values sounding 970621:2027

Date Submitted: 6/23/97
Submitted By:   Barry Lesht           _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________
 
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement: sgpsondewrpnc1
    What level data: (raw,a0,a1,b1,c1 etc): all

    What location was the data collected at: SGP/CF
 
    Period of time in question
        Begin Date  6/21/97    Time   20:27    (GMT)
        End Date               Time            (GMT)

 Data should be labeled:
 ___  questionable                      ___  All data fields affected
 _X_  incorrect                         _X_  Only some data fields affected
 ___  wrong calibration
 ___  others 
 
 Discussion of Problem:

Site operations reports that incorrect surface values were entered into
the subject sounding.  Instead of 972.3, 33.7, and 46 the surface pressure,
temperature, and humidity values should have been 971.8, 33.3, and 47.

The incorrect surface pressure will result in incorrect altitudes throughout
the profile and incorrect ascent rate values during the first 30 seconds.
The effects of the incorrect temperature and relative humidty values should
be negligable.
 
Other observations/measurements impacted by this problem:


Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Flag data.
Measurements:sgpsondewrpnC1.a1:
  • Wind Status(wstat)
  • lon(lon)
  • Relative humidity inside the instrument enclosure(rh)
  • V-component(v_wind)
  • Ascent Rate(asc)
  • Dummy altitude for Zeb(alt)
  • Time offset of tweaks from base_time(time_offset)
  • Wind Direction(deg)
  • Retrieved pressure profile(pres)
  • Dry bulb temperature(tdry)
  • U-component(u_wind)
  • base time(base_time)
  • Surface dew point temperature(dp)
  • Mean Wind Speed(wspd)
  • lat(lat)


Back To Table of Contents

DQRID : D970625.1
Start DateStart TimeEnd DateEnd Time
06/22/1997022806/22/19970236
Subject:
Bad sounding file CF 970622:0228
DataStreams:sgpsondewrpnC1.a1
Description:
It appears that there was a problem with the radiosonde that generated
this short file. The pressure values are unreasonably high and the
file terminated after only 484 seconds of flight.  I note that the
operators started a new sounding at 0252.  This entire file should be
disregarded or deleted.
Measurements:sgpsondewrpnC1.a1:
  • Wind Status(wstat)
  • lon(lon)
  • Relative humidity inside the instrument enclosure(rh)
  • V-component(v_wind)
  • Ascent Rate(asc)
  • Dummy altitude for Zeb(alt)
  • Time offset of tweaks from base_time(time_offset)
  • Wind Direction(deg)
  • Retrieved pressure profile(pres)
  • Dry bulb temperature(tdry)
  • U-component(u_wind)
  • base time(base_time)
  • Surface dew point temperature(dp)
  • Mean Wind Speed(wspd)
  • lat(lat)


Back To Table of Contents

DQRID : D970709.1
Start DateStart TimeEnd DateEnd Time
07/04/1997052507/04/19970630
Subject:
Bad pressure values CF sounding 970704:0525
DataStreams:sgpsondewrpnC1.a1
Description:
The pressure values and hence altitude values are most likely incorrect
in this sounding.  It also appears that an incorrect surface pressure
value was entered by the operator.  The surface pressure value in
the data (986.8) is somewhat higher than the surface pressures for the
neighboring soundings and higher than recorded in the raw data collected
before launch (~978 hPa).  The first pressure value recorded by the
sonde after launch is 884.8 hPa.  Analysis of the absolutely raw data
reveals that the sonde was reading about 978 hPa well before launch,
then suddenly dropped to 886.8 at which it remained stable for several
minutes, then began slowly decreasing as would be expected after launch.
My best guess is that the sonde was somehow damaged during handling
before launch resulting in erroneous pressure values.  Relative pressure
changes from an 'apparent' surface value of 886.8 hPa may be correct,
but the absolute pressure values are not.
Measurements:sgpsondewrpnC1.a1:
  • Wind Status(wstat)
  • lon(lon)
  • Relative humidity inside the instrument enclosure(rh)
  • V-component(v_wind)
  • Ascent Rate(asc)
  • Dummy altitude for Zeb(alt)
  • Time offset of tweaks from base_time(time_offset)
  • Wind Direction(deg)
  • Retrieved pressure profile(pres)
  • Dry bulb temperature(tdry)
  • U-component(u_wind)
  • base time(base_time)
  • Surface dew point temperature(dp)
  • Mean Wind Speed(wspd)
  • lat(lat)


Back To Table of Contents

DQRID : D970923.2
Start DateStart TimeEnd DateEnd Time
09/21/1997053009/21/19970530
Subject:
Pressure jump at launch
DataStreams:sgpsondewrpnC1.a1
Description:
The difference between the first pressure value recorded by the radiosonde
after launch (984.5) that the surface value entered by the operator (989.3)
is somewhat larger than would normally be expected.  This will result in
incorrect altitude values throughout the sounding.  The ascent rates
during the first 30 seconds also will be incorrect.
Measurements:sgpsondewrpnC1.a1:
  • Wind Status(wstat)
  • lon(lon)
  • Relative humidity inside the instrument enclosure(rh)
  • V-component(v_wind)
  • Ascent Rate(asc)
  • Dummy altitude for Zeb(alt)
  • Time offset of tweaks from base_time(time_offset)
  • Wind Direction(deg)
  • Retrieved pressure profile(pres)
  • Dry bulb temperature(tdry)
  • U-component(u_wind)
  • base time(base_time)
  • Surface dew point temperature(dp)
  • Mean Wind Speed(wspd)
  • lat(lat)


Back To Table of Contents

DQRID : D980126.1
Start DateStart TimeEnd DateEnd Time
01/01/1998000012/31/19992359
Subject:
Incorrect radiosonde serial numbers
DataStreams:sgpsondewrpnB1.a0, sgpsondewrpnB1.a1, sgpsondewrpnB4.a0, sgpsondewrpnB4.a1,
sgpsondewrpnB5.a0, sgpsondewrpnB5.a1, sgpsondewrpnB6.a0, sgpsondewrpnB6.a1, sgpsondewrpnC1.a0,
sgpsondewrpnC1.a1
Description:
Radiosondes manufactured at Vaisala's Woburn, MA factory during the first
of January 1998 have incorrect serial numbers.  Instead of being numbered
8012XXXXX these sondes are numbered 7012XXXXX.  Vaisala has been informed
of this, has confirmed the problem, and has corrected their numbering for
all subsequent sondes.  163 incorrectly numbered sondes were shipped to ARM
on 1/9/98.  Some have been used at the CF since 1/19/98:1430.
Measurements:sgpsondewrpnC1.a0:
  • Mean Wind Speed(wspd)
  • Ascent Rate(asc)
  • lon(lon)
  • Surface dew point temperature(dp)
  • lat(lat)
  • Dummy altitude for Zeb(alt)
  • Time offset of tweaks from base_time(time_offset)
  • Retrieved pressure profile(pres)
  • Relative humidity inside the instrument enclosure(rh)
  • Dry bulb temperature(tdry)
  • Wind Status(wstat)
  • Wind Direction(deg)
  • base time(base_time)

sgpsondewrpnB5.a1:
  • Ascent Rate(asc)
  • Dry bulb temperature(tdry)
  • Retrieved pressure profile(pres)
  • base time(base_time)
  • Wind Direction(deg)
  • Time offset of tweaks from base_time(time_offset)
  • Dummy altitude for Zeb(alt)
  • lat(lat)
  • V-component(v_wind)
  • Mean Wind Speed(wspd)
  • Surface dew point temperature(dp)
  • lon(lon)
  • U-component(u_wind)
  • Wind Status(wstat)
  • Relative humidity inside the instrument enclosure(rh)

sgpsondewrpnB4.a0:
  • Time offset of tweaks from base_time(time_offset)
  • Dry bulb temperature(tdry)
  • Retrieved pressure profile(pres)
  • Mean Wind Speed(wspd)
  • Relative humidity inside the instrument enclosure(rh)
  • Dummy altitude for Zeb(alt)
  • Wind Status(wstat)
  • Ascent Rate(asc)
  • lon(lon)
  • base time(base_time)
  • Surface dew point temperature(dp)
  • Wind Direction(deg)
  • lat(lat)

sgpsondewrpnB1.a0:
  • Wind Direction(deg)
  • lat(lat)
  • Ascent Rate(asc)
  • Mean Wind Speed(wspd)
  • Dry bulb temperature(tdry)
  • Relative humidity inside the instrument enclosure(rh)
  • Dummy altitude for Zeb(alt)
  • Retrieved pressure profile(pres)
  • Wind Status(wstat)
  • base time(base_time)
  • Time offset of tweaks from base_time(time_offset)
  • Surface dew point temperature(dp)
  • lon(lon)

sgpsondewrpnB6.a0:
  • lat(lat)
  • base time(base_time)
  • Wind Direction(deg)
  • Surface dew point temperature(dp)
  • Mean Wind Speed(wspd)
  • lon(lon)
  • Time offset of tweaks from base_time(time_offset)
  • Dummy altitude for Zeb(alt)
  • Ascent Rate(asc)
  • Wind Status(wstat)
  • Relative humidity inside the instrument enclosure(rh)
  • Retrieved pressure profile(pres)
  • Dry bulb temperature(tdry)

sgpsondewrpnB5.a0:
  • Time offset of tweaks from base_time(time_offset)
  • Wind Direction(deg)
  • base time(base_time)
  • Dry bulb temperature(tdry)
  • Dummy altitude for Zeb(alt)
  • Ascent Rate(asc)
  • Surface dew point temperature(dp)
  • Wind Status(wstat)
  • lat(lat)
  • Relative humidity inside the instrument enclosure(rh)
  • lon(lon)
  • Retrieved pressure profile(pres)
  • Mean Wind Speed(wspd)

sgpsondewrpnB4.a1:
  • Wind Status(wstat)
  • Time offset of tweaks from base_time(time_offset)
  • V-component(v_wind)
  • Surface dew point temperature(dp)
  • lat(lat)
  • Wind Direction(deg)
  • Mean Wind Speed(wspd)
  • Relative humidity inside the instrument enclosure(rh)
  • Retrieved pressure profile(pres)
  • Dry bulb temperature(tdry)
  • Ascent Rate(asc)
  • lon(lon)
  • U-component(u_wind)
  • Dummy altitude for Zeb(alt)
  • base time(base_time)

sgpsondewrpnB6.a1:
  • Mean Wind Speed(wspd)
  • Relative humidity inside the instrument enclosure(rh)
  • lon(lon)
  • Dummy altitude for Zeb(alt)
  • Retrieved pressure profile(pres)
  • Wind Status(wstat)
  • base time(base_time)
  • V-component(v_wind)
  • Time offset of tweaks from base_time(time_offset)
  • Dry bulb temperature(tdry)
  • U-component(u_wind)
  • Wind Direction(deg)
  • Surface dew point temperature(dp)
  • Ascent Rate(asc)
  • lat(lat)

sgpsondewrpnC1.a1:
  • Relative humidity inside the instrument enclosure(rh)
  • lat(lat)
  • lon(lon)
  • U-component(u_wind)
  • Dry bulb temperature(tdry)
  • base time(base_time)
  • Surface dew point temperature(dp)
  • Ascent Rate(asc)
  • Dummy altitude for Zeb(alt)
  • Wind Direction(deg)
  • V-component(v_wind)
  • Time offset of tweaks from base_time(time_offset)
  • Wind Status(wstat)
  • Retrieved pressure profile(pres)
  • Mean Wind Speed(wspd)

sgpsondewrpnB1.a1:
  • Wind Direction(deg)
  • Dry bulb temperature(tdry)
  • Wind Status(wstat)
  • Ascent Rate(asc)
  • U-component(u_wind)
  • Surface dew point temperature(dp)
  • Time offset of tweaks from base_time(time_offset)
  • Retrieved pressure profile(pres)
  • lon(lon)
  • lat(lat)
  • V-component(v_wind)
  • Dummy altitude for Zeb(alt)
  • Mean Wind Speed(wspd)
  • Relative humidity inside the instrument enclosure(rh)
  • base time(base_time)


Back To Table of Contents



END OF DATA