Data Quality Reports for Session: 110827 User: anderberg Completed: 03/03/2008


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D040420.4SGP/SIRS/E27 - incorrect trackingsgpsirs20sE27.a0, sgpsirsE27.00, sgpsirsE27.b1
D050117.1SGP/SIRS/E9 - Unknown -failed PSP ventilator fansgpsirs20sE9.a0, sgpsirsE9.00, sgpsirsE9.b1
D050218.1SGP/SIRS/E7 - Reprocessed: Corrected Downwelling Longwave calibrationssgpsirsE7.b1
D060630.10SGP/SIRS/E2 - Reprocessed: Longwave Calibration errorsgpsirsE2.b1
D060630.11SGP/SIRS/E3 - Reprocessed: Longwave Calibration errorsgpsirsE3.b1
D060630.12SGP/SIRS/E4 - Reprocessed: Longwave Calibration errorsgpsirsE4.b1
D060630.13SGP/SIRS/E5 - Reprocessed: Longwave Calibration errorsgpsirsE5.b1
D060630.14SGP/SIRS/E6 - Reprocessed: Longwave Calibration errorsgpsirsE6.b1
D060630.15SGP/SIRS/E7 - Reprocessed: Longwave Calibration errorsgpsirsE7.b1
D060630.16SGP/SIRS/E8 - Reprocessed: Longwave Calibration errorsgpsirsE8.b1
D060630.17SGP/SIRS/E9 - Reprocessed: Longwave Calibration errorsgpsirsE9.b1
D060630.26SGP/SIRS/E20 - Reprocessed: Longwave Calibration errorsgpsirsE20.b1
D060630.27SGP/SIRS/E21 - Reprocessed: Longwave Calibration errorsgpsirsE21.b1
D060630.28SGP/SIRS/E22 - Reprocessed: Longwave Calibration errorsgpsirsE22.b1
D060630.29SGP/SIRS/E24 - Reprocessed: Longwave Calibration errorsgpsirsE24.b1
D060630.30SGP/SIRS/E27 - Reprocessed: Longwave Calibration errorsgpsirsE27.b1


DQRID : D040420.4
Start DateStart TimeEnd DateEnd Time
04/14/2004170009/15/20041650
10/27/2004150011/05/20041900
Subject:
SGP/SIRS/E27 - incorrect tracking
DataStreams:sgpsirs20sE27.a0, sgpsirsE27.00, sgpsirsE27.b1
Description:
The solar tracker at E27 was not functioning properly.  The problem affected tracker 
mounted instruments: downwelling diffuse 8-48 and direct normal pyrheliometer NIP.  

After tracker adjustment on 4/14/2004 1700GMT the tracker stopped tracking properly during 
afternoon hours.  Attempts to correct tracker operation throughout the failure period 
resulted in variations on incorrect tracker operation.  No replacement tracker was available.

After adjustment on 9/15/2004 the tracker problem was resolved.  It is unclear what, other 
than typical az and zen tracker software changes by field techs, corrected the problem.  
This problem period corresponds to the first time range specified (4/14 to 9/15). 

On 10/27/2004 a replacement tracker was installed at E27.  Technical difficulties kept 
tracker out of service until 11/05/2004. The replacement tracker at E27 was put into serice 
by the field techs on 11/05/2004 1830GMT.  The tracker has been tracking correctly since 
this time.  This problem period corresponds to the second time range (10/27 to 11/05).
Measurements:sgpsirsE27.00:
  • Raw data stream - documentation not supported(Raw data stream - documentation not supported)

sgpsirsE27.b1:
  • Shortwave Direct Normal Irradiance, Pyrgeometer, Maxima(short_direct_normal_max)
  • Shortwave Direct Normal Irradiance, Pyrgeometer, Minima(short_direct_normal_min)
  • Downwelling Shortwave Diffuse Hemispheric Irradiance, Ventilated Pyranometer,
    Minima(down_short_diffuse_hemisp_min)
  • Downwelling Shortwave Diffuse Hemispheric Irradiance, Ventilated Pyranometer,
    Maxima(down_short_diffuse_hemisp_max)
  • Downwelling Shortwave Diffuse Hemispheric Irradiance, Ventilated Pyranometer(down_short_diffuse_hemisp)
  • Shortwave Direct Normal Irradiance, Pyrgeometer, Standard Deviation(short_direct_normal_std)
  • Shortwave Direct Normal Irradiance, Pyrgeometer(short_direct_normal)
  • Downwelling Shortwave Hemispheric Irradiance, Pyranometer, Standard Deviation(down_short_diffuse_hemisp_std)

sgpsirs20sE27.a0:
  • Instantaneous Uncorrected Downwelling Shortwave Diffuse, Shaded Pyranometer
    Thermopile Voltage(inst_diffuse)
  • Instantaneous Direct Normal Shortwave Irradiance, Pyheliometer Thermopile
    Voltage(inst_direct_normal)


Back To Table of Contents

DQRID : D050117.1
Start DateStart TimeEnd DateEnd Time
12/23/2004231501/25/20051800
Subject:
SGP/SIRS/E9 - Unknown -failed PSP ventilator fan
DataStreams:sgpsirs20sE9.a0, sgpsirsE9.00, sgpsirsE9.b1
Description:
Downwelling shortwave hemispheric (DSH) readings appear to have a slight to moderate 
negative offset from derived DSH values.  At night, this negative offset causes qc flags 
(since values are below the minimum threshold of -10 W/m^2).  Differences between derived and 
actual DSH values are sometimes on the order of 50 W/m^2 due to this offset. 
The offset was discovered to be due to a failed ventilator fan which is used to clear the 
dome of the PSP, the instrument which measures the DSH.  The ventilator likely seized or 
was intermittent and heated the PSP base giving an erroneous DSH reading.  Field techs 
replaced the fan on 01/25/2005 1745GMT.  The DSH has been reading normally since that time.
Measurements:sgpsirs20sE9.a0:
  • Instantaneous Downwelling Hemispheric Shortwave, Unshaded Pyranometer Thermopile
    Voltage(inst_global)

sgpsirsE9.b1:
  • Downwelling Shortwave Hemispheric Irradiance, Ventilated Pyranometer, Standard
    Deviation(down_short_hemisp_std)
  • Downwelling Shortwave Hemispheric Irradiance, Ventilated Pyranometer, Minima(down_short_hemisp_min)
  • Down-welling unshaded pyranometer voltage(down_short_hemisp)
  • Downwelling Shortwave Hemispheric Irradiance, Ventilated Pyranometer, Maxima(down_short_hemisp_max)

sgpsirsE9.00:
  • Raw data stream - documentation not supported(Raw data stream - documentation not supported)


Back To Table of Contents

DQRID : D050218.1
Start DateStart TimeEnd DateEnd Time
11/02/2004204502/22/20052050
Subject:
SGP/SIRS/E7 - Reprocessed: Corrected Downwelling Longwave calibrations
DataStreams:sgpsirsE7.b1
Description:
Incorrect DIR calibration coeffs and serial numbers were applied to the data from 
11/02/2004 when the shortwave instruments were changed out.  Field techs corrected the program 
during longwave instrument replacement on 2/22/2005.

The data were reprocessed in September 2006 to apply the correct calibrations.  The 
reprocessed data were archived in October 2006.
Measurements:sgpsirsE7.b1:
  • Downwelling Longwave Hemispheric Irradiance, Shaded Pyrgeometer, Standard
    Deviation(down_long_hemisp_shaded_std)
  • Downwelling Longwave Hemispheric Irradiance, Shaded Pyrgeometer, Minima(down_long_hemisp_shaded_min)
  • Downwelling Longwave Hemispheric Net Infrared(down_long_netir)
  • Instantaneous Downwelling Pyrgeometer Dome Thermistor Temperature, Shaded
    Pyrgeometer(inst_down_long_shaded_dome_temp)
  • Downwelling Longwave Hemispheric Irradiance, Shaded Pyrgeometer(down_long_hemisp_shaded)
  • Downwelling Longwave Hemispheric Irradiance, Shaded Pyrgeometer, Maxima(down_long_hemisp_shaded_max)
  • Instantaneous Downwelling Pyrgeometer Case Thermistor Temperature, Shaded
    Pyrgeometer(inst_down_long_shaded_case_temp)


Back To Table of Contents

DQRID : D060630.10
Start DateStart TimeEnd DateEnd Time
02/12/2004163002/23/20051615
Subject:
SGP/SIRS/E2 - Reprocessed: Longwave Calibration error
DataStreams:sgpsirsE2.b1
Description:
Modified pyrgeometer calibration procedures were implemented beginning in February 2004. 
These modified procedures introduced a calibration bias in the longwave data.  The 
previous procedures were re-implemented at all sites between December 2005 and February 2006 to 
restore proper calibrations.

The data collected while the incorrect procedures were in place have been reprocessed to 
remove the calibration bias.  The reprocessed 60 second averaged data are based on 3 
instantaneous 20 second data records rather than on 60 1 second instanteous data records.  
Still, these data are considered far superior to the originally processed data.  The 
reprocessed data were archived in September 2006.
Measurements:sgpsirsE2.b1:
  • Upwelling (10 meter) Longwave Hemispheric Irradiance, Pyrgeometer(up_long_hemisp)
  • Upwelling Longwave Hemispheric Net Infrared(up_long_netir)
  • Downwelling Longwave Hemispheric Net Infrared(down_long_netir)
  • Downwelling Longwave Hemispheric Irradiance, Shaded Pyrgeometer(down_long_hemisp_shaded)


Back To Table of Contents

DQRID : D060630.11
Start DateStart TimeEnd DateEnd Time
03/10/2004171502/08/20061730
Subject:
SGP/SIRS/E3 - Reprocessed: Longwave Calibration error
DataStreams:sgpsirsE3.b1
Description:
Modified pyrgeometer calibration procedures were implemented beginning in March 2004. 
These modified procedures introduced a calibration bias in the longwave data.  The previous 
procedures were re-implemented at all sites between December 2005 and February 2006 to 
restore proper calibrations.									      
The data collected while the incorrect procedures were in place have been reprocessed to 
remove the calibration bias.  The reprocessed 60 second  averaged data are based on 3 
instantaneous 20 second data records rather than on 60 1 second instantaneous data records.  
Still, these data are considered far superior to the originally processed data. The 
reprocessed data were archived in August 2006.
Measurements:sgpsirsE3.b1:
  • Downwelling Longwave Hemispheric Net Infrared(down_long_netir)
  • Downwelling Longwave Hemispheric Irradiance, Shaded Pyrgeometer(down_long_hemisp_shaded)
  • Upwelling Longwave Hemispheric Net Infrared(up_long_netir)
  • Upwelling (10 meter) Longwave Hemispheric Irradiance, Pyrgeometer(up_long_hemisp)


Back To Table of Contents

DQRID : D060630.12
Start DateStart TimeEnd DateEnd Time
03/10/2004172002/22/20061615
Subject:
SGP/SIRS/E4 - Reprocessed: Longwave Calibration error
DataStreams:sgpsirsE4.b1
Description:
Modified pyrgeometer calibration procedures were implemented beginning in March 2004. 
These modified procedures introduced a calibration bias in the longwave data. The previous 
procedures were re-implemented at all sites between December 2005 and February 2006 to 
restore proper calibrations.

The data collected while the incorrect procedures were in place have been reprocessed to 
remove the calibration bias.  The reprocessed 60 second averaged data are based on 3 
instantaneous 20 second data records rather than on 60 1 second instantaneous data records.  
Still, these data are considered far superior to the originally processed data. The 
reprocessed data were archived in October 2006.
Measurements:sgpsirsE4.b1:
  • Upwelling (10 meter) Longwave Hemispheric Irradiance, Pyrgeometer(up_long_hemisp)
  • Downwelling Longwave Hemispheric Irradiance, Shaded Pyrgeometer(down_long_hemisp_shaded)
  • Upwelling Longwave Hemispheric Net Infrared(up_long_netir)
  • Downwelling Longwave Hemispheric Net Infrared(down_long_netir)


Back To Table of Contents

DQRID : D060630.13
Start DateStart TimeEnd DateEnd Time
03/10/2004203002/22/20061817
Subject:
SGP/SIRS/E5 - Reprocessed: Longwave Calibration error
DataStreams:sgpsirsE5.b1
Description:
Modified pyrgeometer calibration procedures were implemented beginning in March 2004. 
These modified procedures introduced a calibration bias in the longwave data. The previous 
procedures were re-implemented at all sites between December 2005 and February 2006 to 
restore proper calibrations.

The data collected while the incorrect procedures were in place have been reprocessed to 
remove the calibration bias.  The reprocessed 60 second averaged data are based on 3 
instantaneous 20 second data records rather than on 60 1 second instantaneous data records.  
Still, these data are considered far superior to the originally processed data. The 
reprocessed data were archived in October 2006.
Measurements:sgpsirsE5.b1:
  • Downwelling Longwave Hemispheric Irradiance, Shaded Pyrgeometer(down_long_hemisp_shaded)
  • Upwelling (10 meter) Longwave Hemispheric Irradiance, Pyrgeometer(up_long_hemisp)
  • Upwelling Longwave Hemispheric Net Infrared(up_long_netir)
  • Downwelling Longwave Hemispheric Net Infrared(down_long_netir)


Back To Table of Contents

DQRID : D060630.14
Start DateStart TimeEnd DateEnd Time
03/11/2004161002/09/20061553
Subject:
SGP/SIRS/E6 - Reprocessed: Longwave Calibration error
DataStreams:sgpsirsE6.b1
Description:
Modified pyrgeometer calibration procedures were implemented beginning in March 2004. 
These modified procedures introduced a calibration bias in the longwave data. The previous 
procedures were re-implemented at all sites between December 2005 and February 2006 to 
restore proper calibrations.

The data collected while the incorrect procedures were in place have been reprocessed to 
remove the calibration bias.  The reprocessed 60 second averaged data are based on 3 
instantaneous 20 second data records rather than on 60 1 second instantaneous data records.  
Still, these data are considered far superior to the originally processed data. The 
reprocessed data were archived in October 2006.
Measurements:sgpsirsE6.b1:
  • Upwelling (10 meter) Longwave Hemispheric Irradiance, Pyrgeometer(up_long_hemisp)
  • Downwelling Longwave Hemispheric Irradiance, Shaded Pyrgeometer(down_long_hemisp_shaded)
  • Downwelling Longwave Hemispheric Net Infrared(down_long_netir)
  • Upwelling Longwave Hemispheric Net Infrared(up_long_netir)


Back To Table of Contents

DQRID : D060630.15
Start DateStart TimeEnd DateEnd Time
02/20/2004200002/07/20062005
Subject:
SGP/SIRS/E7 - Reprocessed: Longwave Calibration error
DataStreams:sgpsirsE7.b1
Description:
Modified pyrgeometer calibration procedures were implemented beginning in February 2004. 
These modified procedures introduced a calibration bias in the longwave data. The previous 
procedures were re-implemented at all sites between December 2005 and February 2006 to 
restore proper calibrations.

The data collected while the incorrect procedures were in place have been reprocessed to 
remove the calibration bias.  The reprocessed 60 second averaged data are based on 3 
instantaneous 20 second data records rather than on 60 1 second instantaneous data records.  
Still, these data are considered far superior to the originally processed data. The 
reprocessed data were archived in October 2006.
Measurements:sgpsirsE7.b1:
  • Downwelling Longwave Hemispheric Net Infrared(down_long_netir)
  • Upwelling (10 meter) Longwave Hemispheric Irradiance, Pyrgeometer(up_long_hemisp)
  • Downwelling Longwave Hemispheric Irradiance, Shaded Pyrgeometer(down_long_hemisp_shaded)
  • Upwelling Longwave Hemispheric Net Infrared(up_long_netir)


Back To Table of Contents

DQRID : D060630.16
Start DateStart TimeEnd DateEnd Time
02/10/2004184502/21/20061840
Subject:
SGP/SIRS/E8 - Reprocessed: Longwave Calibration error
DataStreams:sgpsirsE8.b1
Description:
Modified pyrgeometer calibration procedures were implemented beginning in February 2004.  
These modified procedures introduced a calibration bias in the longwave data.  The 
previous procedures were re-implemented at all sites between December 2005 and February 2006 to 
restore proper calibrations.

The data collected while the incorrect procedures were in place have been reprocessed to 
remove the calibration bias.  The reprocessed 60 second averaged data are based on 3 
instantaneous 20 second data records rather than on 60 1 second instanteous data records. 
Still, these data are considered far superior to the originally processed data. The 
reprocessed data were archived in September 2006.
Measurements:sgpsirsE8.b1:
  • Upwelling Longwave Hemispheric Net Infrared(up_long_netir)
  • Upwelling (10 meter) Longwave Hemispheric Irradiance, Pyrgeometer(up_long_hemisp)
  • Downwelling Longwave Hemispheric Irradiance, Shaded Pyrgeometer(down_long_hemisp_shaded)
  • Downwelling Longwave Hemispheric Net Infrared(down_long_netir)


Back To Table of Contents

DQRID : D060630.17
Start DateStart TimeEnd DateEnd Time
12/17/2003164002/07/20061730
Subject:
SGP/SIRS/E9 - Reprocessed: Longwave Calibration error
DataStreams:sgpsirsE9.b1
Description:
Modified pyrgeometer calibration procedures were implemented beginning in December 2003. 
These modified procedures introduced a calibration bias in the longwave data.  The 
previous procedures were re-implemented at all sites between December 2005 and February 2006 to 
restore proper calibrations.

The data collected while the incorrect procedures were in place have been reprocessed to 
remove the calibration bias.  The reprocessed 60 second averaged data are based on 3 
instantaneous 20 second data records rather than on 60 1 second instanteous data records. 
Still, these data are considered far superior to the originally processed data. The 
reprocessed data were archived in October 2006.
Measurements:sgpsirsE9.b1:
  • Upwelling (10 meter) Longwave Hemispheric Irradiance, Pyrgeometer(up_long_hemisp)
  • Downwelling Longwave Hemispheric Irradiance, Shaded Pyrgeometer(down_long_hemisp_shaded)
  • Downwelling Longwave Hemispheric Net Infrared(down_long_netir)
  • Upwelling Longwave Hemispheric Net Infrared(up_long_netir)


Back To Table of Contents

DQRID : D060630.26
Start DateStart TimeEnd DateEnd Time
07/23/2003210002/15/20062030
Subject:
SGP/SIRS/E20 - Reprocessed: Longwave Calibration error
DataStreams:sgpsirsE20.b1
Description:
Modified pyrgeometer calibration procedures were implemented beginning in July 2003. These 
modified procedures introduced a calibration bias in the longwave data. The previous 
procedures were re-implemented at all sites between December 2005 and February 2006 to 
restore proper calibrations. 

The data collected while the incorrect procedures were in place have been reprocessed to 
remove the calibration bias.  The reprocessed 60 second averaged data are based on 3 
instantaneous 20 second data records rather than on 60 1 second instantaneous data records. 
Still, these data are considered far superior to the originally processed data. The 
reprocessed data were archived in November 2006.
Measurements:sgpsirsE20.b1:
  • Upwelling Longwave Hemispheric Net Infrared(up_long_netir)
  • Downwelling Longwave Hemispheric Irradiance, Shaded Pyrgeometer(down_long_hemisp_shaded)
  • Upwelling (10 meter) Longwave Hemispheric Irradiance, Pyrgeometer(up_long_hemisp)
  • Downwelling Longwave Hemispheric Net Infrared(down_long_netir)


Back To Table of Contents

DQRID : D060630.27
Start DateStart TimeEnd DateEnd Time
07/23/2003152002/15/20061515
Subject:
SGP/SIRS/E21 - Reprocessed: Longwave Calibration error
DataStreams:sgpsirsE21.b1
Description:
Modified pyrgeometer calibration procedures were implemented beginning in July 2003. These 
modified procedures introduced a calibration bias in the longwave data. The previous 
procedures were re-implemented at all sites between December 2005 and February 2006 to 
restore proper calibrations. 

The data collected while the incorrect procedures were in place have been reprocessed to 
remove the calibration bias.  The reprocessed 60 second averaged data are based on 3 
instantaneous 20 second data records rather than on 60 1 second instantaneous data records. 
Still, these data are considered far superior to the originally processed data. The 
reprocessed data were archived in November 2006.
Measurements:sgpsirsE21.b1:
  • Downwelling Longwave Hemispheric Net Infrared(down_long_netir)
  • Upwelling (10 meter) Longwave Hemispheric Irradiance, Pyrgeometer(up_long_hemisp)
  • Downwelling Longwave Hemispheric Irradiance, Shaded Pyrgeometer(down_long_hemisp_shaded)
  • Upwelling Longwave Hemispheric Net Infrared(up_long_netir)


Back To Table of Contents

DQRID : D060630.28
Start DateStart TimeEnd DateEnd Time
07/23/2003183002/15/20061741
Subject:
SGP/SIRS/E22 - Reprocessed: Longwave Calibration error
DataStreams:sgpsirsE22.b1
Description:
Modified pyrgeometer calibration procedures were implemented beginning in July 2003.  
These modified procedures introduced a calibration bias in the longwave data.  The previous 
procedures were re-implemented at all sites between December 2005 and February 2006 to 
restore proper calibrations.    
                                                                         
The data collected while the incorrect procedures were in place have been reprocessed to 
remove the calibration bias.  The reprocessed 60 second averaged data are based on 3 
instantaneous 20 second data records rather than on 60 1 second instantaneous data records. 
Still, these data are considered far superior to the originally processed data. The 
reprocessed data were archived in August 2006.
Measurements:sgpsirsE22.b1:
  • Upwelling Longwave Hemispheric Net Infrared(up_long_netir)
  • Downwelling Longwave Hemispheric Net Infrared(down_long_netir)
  • Upwelling (10 meter) Longwave Hemispheric Irradiance, Pyrgeometer(up_long_hemisp)
  • Downwelling Longwave Hemispheric Irradiance, Shaded Pyrgeometer(down_long_hemisp_shaded)


Back To Table of Contents

DQRID : D060630.29
Start DateStart TimeEnd DateEnd Time
07/24/2003164002/16/20061705
Subject:
SGP/SIRS/E24 - Reprocessed: Longwave Calibration error
DataStreams:sgpsirsE24.b1
Description:
Modified pyrgeometer calibration procedures were implemented beginning in July 2004. These 
modified procedures introduced a calibration bias in the longwave data. The previous 
procedures were re-implemented at all sites between December 2005 and February 2006 to 
restore proper calibrations. 

The data collected while the incorrect procedures were in place have been reprocessed to 
remove the calibration bias.  The reprocessed 60 second averaged data are based on 3 
instantaneous 20 second data records rather than on 60 1 second instantaneous data records. 
Still, these data are considered far superior to the originally processed data. The 
reprocessed data were archived in October 2006.
Measurements:sgpsirsE24.b1:
  • Downwelling Longwave Hemispheric Irradiance, Shaded Pyrgeometer(down_long_hemisp_shaded)
  • Downwelling Longwave Hemispheric Net Infrared(down_long_netir)
  • Upwelling Longwave Hemispheric Net Infrared(up_long_netir)
  • Upwelling (10 meter) Longwave Hemispheric Irradiance, Pyrgeometer(up_long_hemisp)


Back To Table of Contents

DQRID : D060630.30
Start DateStart TimeEnd DateEnd Time
05/16/2003000202/15/20061750
Subject:
SGP/SIRS/E27 - Reprocessed: Longwave Calibration error
DataStreams:sgpsirsE27.b1
Description:
Modified pyrgeometer calibration procedures were implemented beginning in May 2003. These 
modified procedures introduced a calibration bias in the longwave data. The previous 
procedures were re-implemented at all sites between December 2005 and February 2006 to 
restore proper calibrations. 

The data collected while the incorrect procedures were in place have been reprocessed to 
remove the calibration bias.  The reprocessed 60 second averaged data are based on 3 
instantaneous 20 second data records rather than on 60 1 second instantaneous data records. 
Still, these data are considered far superior to the originally processed data. The 
reprocessed data were archived in October 2006.
Measurements:sgpsirsE27.b1:
  • Upwelling Longwave Hemispheric Net Infrared(up_long_netir)
  • Upwelling (10 meter) Longwave Hemispheric Irradiance, Pyrgeometer(up_long_hemisp)
  • Downwelling Longwave Hemispheric Net Infrared(down_long_netir)
  • Downwelling Longwave Hemispheric Irradiance, Shaded Pyrgeometer(down_long_hemisp_shaded)


Back To Table of Contents



END OF DATA