Data Quality Reports for Session: 110383 User: gtodini Completed: 02/09/2008


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D060928.4NSA/SONDE/C1 - Increased precision for alt, dp, pres, rh, tdrynsasondewnpnC1.b1
D070709.1NSA/MWRP/C1 - Reprocessed: 6-channel retrieval replaced by 5-channel retrievalnsamwrpC1.b1


DQRID : D060928.4
Start DateStart TimeEnd DateEnd Time
09/29/2006050012/31/99992359
Subject:
NSA/SONDE/C1 - Increased precision for alt, dp, pres, rh, tdry
DataStreams:nsasondewnpnC1.b1
Description:
The output precision of the following variables was increased 20060929:

   alt	changed from 1m to 0.1m
   dp	changed from 0.1degC to 0.01degC
   pres changed from 0.1 hPa to 0.01 hPa
   RH	changed from 1%RH to 0.01%RH
   tdry changed from .1degC to 0.01degC

Note that the increase in precision does not necessarily imply an increase
in accuracy.  Users are cautioned to continue to use their best scientific
judgement when using these or any other data.
Measurements:nsasondewnpnC1.b1:
  • Relative humidity inside the instrument enclosure(rh)
  • Dry bulb temperature(tdry)
  • Dummy altitude for Zeb(alt)
  • Retrieved pressure profile(pres)
  • Surface dew point temperature(dp)


Back To Table of Contents

DQRID : D070709.1
Start DateStart TimeEnd DateEnd Time
02/19/2004021406/02/20072359
Subject:
NSA/MWRP/C1 - Reprocessed: 6-channel retrieval replaced by 5-channel retrieval
DataStreams:nsamwrpC1.b1
Description:
Due to repeated failure of the V-band receiver and calibration problems, the 6-channel 
retrieval was retired and a new 5-channel retrieval which uses only the K-band channels was 
implemented.

All data previously processed with the 6-channel retrieval have been reprocessed.
Measurements:nsamwrpC1.b1:
  • Retrieved liquid water path(liquidWaterPath)
  • Retrieved liquid water path using only 23.835 and 30.0 GHz(liquidWaterPath2)
  • Microwave brightness temperature(brightnessTemperature)


Back To Table of Contents



END OF DATA