Data Quality Reports for Session: 110037 User: kjohnson Completed: 01/21/2008


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D030212.1TWP/SMET/C3 - Intermittent Pressure Sensor Failuretwpsmet60sC3.a1, twpsmet60sC3.b1
D040726.3TWP/SMET/C3 - Negative rainfall ratestwpsmet60sC3.b1
D051028.5TWP/MPL/C3 - Reprocess: Global metadata errortwpmplC3.a1
D060818.3TWP/SMET/C3 - Reprocess: Barometric Data Changed from hPa to kPatwpsmet60sC3.b1
D061011.4TWP/SMET/C3 - Reprocess: Tipping bucket rain gauge addedtwpsmet60sC3.b1


DQRID : D030212.1
Start DateStart TimeEnd DateEnd Time
10/23/2002000002/06/20032203
Subject:
TWP/SMET/C3 - Intermittent Pressure Sensor Failure
DataStreams:twpsmet60sC3.a1, twpsmet60sC3.b1
Description:
The Barometric Pressure sensor was intermittently failing at TWP site C3 Darwin.  At times 
there were large pressure fluctuations occurring on the order of 24 mb in a few minutes. 
 Times of large pressure fluctuations are readily apparent in the data.  At these times 
the data should be carefully analyzed before determining it's usefulness.  In between the 
periods of large fluctuations the readings appear to be stable.  It is still suggested 
that independent pressure data be obtained for comparison before use.
Measurements:twpsmet60sC3.a1:
  • Barometric Pressure(atmos_pressure)

twpsmet60sC3.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D040726.3
Start DateStart TimeEnd DateEnd Time
03/12/2002062805/17/20042300
Subject:
TWP/SMET/C3 - Negative rainfall rates
DataStreams:twpsmet60sC3.b1
Description:
Due to limitations of the Zeno dataloggers all voltage measurements
from the optical rain gauge (ORG) were converted to rainfall rates. 
This resulted in negative values for rain rates.  Any value below
0.10 mm/hr should be considered to be 0 mm/hr.  New dataloggers 
alleviated this problem.
Measurements:twpsmet60sC3.b1:
  • Precipitation mean(precip_mean)
  • Precipitation maximum(precip_max)
  • Precipitation standard deviation(precip_sd)
  • precipitation minimum(precip_min)


Back To Table of Contents

DQRID : D051028.5
Start DateStart TimeEnd DateEnd Time
08/08/2002004107/22/20031447
Subject:
TWP/MPL/C3 - Reprocess: Global metadata error
DataStreams:twpmplC3.a1
Description:
During the time period specified, the global metadata attribute "averaging_int" is 
reported as 30 seconds when the value for this attribute should be 60 seconds.
Measurements:twpmplC3.a1:
  • Time offset of tweaks from base_time(time_offset)


Back To Table of Contents

DQRID : D060818.3
Start DateStart TimeEnd DateEnd Time
12/02/2003000007/13/20062219
Subject:
TWP/SMET/C3 - Reprocess: Barometric Data Changed from hPa to kPa
DataStreams:twpsmet60sC3.b1
Description:
Barometric pressure data was converted from hPa to kPa in order to standardize the 
measurement units among ARM sites and to conform to accepted standard units determined by the 
scientific community.
Measurements:twpsmet60sC3.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D061011.4
Start DateStart TimeEnd DateEnd Time
03/12/2002000009/26/20061435
Subject:
TWP/SMET/C3 - Reprocess: Tipping bucket rain gauge added
DataStreams:twpsmet60sC3.b1
Description:
A tipping bucket rain gauge was added to the SMET suite of instruments effective 20060926. 
 Two new variables (count and rain amount) were added at the end of the twpsmet60sC1.b1 
datastream.  When reprocessing of this datastream occurs these variables will be added 
with -9999 (missing) as the value for dates prior to gauge installation.
Measurements:twpsmet60sC3.b1:
  • base time(base_time)


Back To Table of Contents



END OF DATA