Data Quality Reports for Session: 109183 User: dhartsock Completed: 11/30/2007


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D070402.1SGP/ECOR/E21 - Intermittent incorrect flux measurementssgp30ecorE21.b1
D070508.1SGP/EBBR/E4 - Instrument problemsgp15ebbrE4.b1, sgp30ebbrE4.b1, sgp5ebbrE4.b1
D070510.1SGP/ECOR/E5 - Flux Measurements Incorrectsgp30ecorE5.b1
D070514.2SGP/ECOR/E14 - IRGA Temperature Incorrect or Missingsgp30ecorE14.b1


DQRID : D070402.1
Start DateStart TimeEnd DateEnd Time
03/01/2007080008/29/20071730
Subject:
SGP/ECOR/E21 - Intermittent incorrect flux measurements
DataStreams:sgp30ecorE21.b1
Description:
At various times during the period, the LI-7500 CO2/H2O serial and analog signals from the 
LI-7500 were missing, but usually not at the same time.

When the CO2/H2O serial datastream was missing, the Pressure and Temperature were missing; 
this did not, in itself, result in incorrect fluxes, as default values for pressure and 
temperature are automatically used.

Fluxes were incorrect when the CO2/H2O analog datastream was missing; these
times are identified by the qc checks.
Measurements:sgp30ecorE21.b1:
  • latent heat flux(lv_e)
  • covariance wc(cvar_wc)
  • average atmospheric pressure (IGRA internal sensor)(atm_pres)
  • covariance wq(cvar_wq)
  • CO2 flux(fc)
  • average temperature (IGRA internal sensor)(temp_irga)


Back To Table of Contents

DQRID : D070508.1
Start DateStart TimeEnd DateEnd Time
05/06/2007163005/16/20071840
Subject:
SGP/EBBR/E4 - Instrument problem
DataStreams:sgp15ebbrE4.b1, sgp30ebbrE4.b1, sgp5ebbrE4.b1
Description:
Wind direction was flat lining near zero and incorrect.
Measurements:sgp5ebbrE4.b1:
  • wind direction (relative to true north)(wind_d)
  • standard deviation of wind direction (sigma theta)(sigma_wd)

sgp30ebbrE4.b1:
  • wind direction (relative to true north)(wind_d)
  • standard deviation of wind direction (sigma theta)(sigma_wd)

sgp15ebbrE4.b1:
  • Wind direction (relative to true north)(mv_wind_d)


Back To Table of Contents

DQRID : D070510.1
Start DateStart TimeEnd DateEnd Time
11/20/2005193012/14/20051930
04/18/2007193005/17/20071815
Subject:
SGP/ECOR/E5 - Flux Measurements Incorrect
DataStreams:sgp30ecorE5.b1
Description:
The ECOR datastream was corrupted; this happens when the ECOR program produces a 
datastream of the wrong length (i.e., leaves one or more measurements out).

Fluxes and some other measurements are incorrect.

Note: Mentor reports reprocessing will not correct this problem.
Measurements:sgp30ecorE5.b1:
  • latent heat flux(lv_e)
  • CO2 flux(fc)
  • h(h)


Back To Table of Contents

DQRID : D070514.2
Start DateStart TimeEnd DateEnd Time
05/09/2007130005/19/20071700
Subject:
SGP/ECOR/E14 - IRGA Temperature Incorrect or Missing
DataStreams:sgp30ecorE14.b1
Description:
The temp_irga was too large 05/09/07 1300 GMT - 05/10/07 2000 GMT.

The temp_irga was flat lined at 49.96 C 05/10/07 2030 GMT - 05/17/07 2000 GMT.  

The temp_irga was missing 05/17/07 2030 GMT - 05/19/07 1700 GMT.
Measurements:sgp30ecorE14.b1:
  • average temperature (IGRA internal sensor)(temp_irga)


Back To Table of Contents



END OF DATA