Data Quality Reports for Session: 102490 User: gustafson Completed: 11/03/2006


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D040427.1SGP/SMOS/E4 - RH Sensor failuresgp1smosE4.b1, sgp30smosE4.b1, sgp1440smosE4.b1
D040524.2SGP/SMOS/E11 - Sensor failing during saturation conditionssgp1smosE11.b1, sgp30smosE11.b1, sgp1440smosE11.b1
D040524.3SGP/SMOS/E21 - Sensor failuresgp1smosE21.b1, sgp30smosE21.b1, sgp1440smosE21.b1
D050421.10SGP/SMOS/E4 - Reprocess: Wind direction offsetsgp1smosE4.b1, sgp30smosE4.b1
D050421.7SGP/SMOS/E3 - Reprocess: Wind direction offsetsgp1smosE3.b1, sgp30smosE3.b1
D050422.2SGP/SMOS/E6 - Reprocess: Wind direction offsetsgp1smosE6.b1, sgp30smosE6.b1
D050422.5SGP/SMOS/E7 - Reprocess: Wind direction offsetsgp1smosE7.b1, sgp30smosE7.b1
D050422.9SGP/SMOS/E27 - Reprocess: Wind direction offsetsgp1smosE27.b1, sgp30smosE27.b1


DQRID : D040427.1
Start DateStart TimeEnd DateEnd Time
04/22/2004163105/06/20041531
Subject:
SGP/SMOS/E4 - RH Sensor failure
DataStreams:sgp1smosE4.b1, sgp30smosE4.b1, sgp1440smosE4.b1
Description:
The RH sensor at this site dropped anomalously to zero on 4/21, and 
was consistently 25% lower than EBBR RH readings on 4/23.  Sensor was 
replaced 5/6.
Measurements:sgp1smosE4.b1:
  • Relative humidity scaled, by total column amount from MWR(rh)
  • Vapor Pressure (kiloPascals)(vap_pres)

sgp30smosE4.b1:
  • Vapor Pressure (kiloPascals)(vap_pres)
  • Standard deviation of Vapor Pressure(sd_vap_pres)
  • Relative humidity scaled, by total column amount from MWR(rh)
  • Standard deviation of Relative Humidity(sd_rh)

sgp1440smosE4.b1:
  • Maximum Relative Humidity(max_rh)
  • Time of Minimum Relative Humidity(time_min_rh)
  • Time of Maximum Relative Humidity(time_max_rh)
  • Time of Minimum Vapor Pressure(time_min_vap_pres)
  • Minimum Relative Humidity(min_rh)
  • Minimum Vapor Pressure(min_vap_pres)
  • Maximum Vapor Pressure(max_vap_pres)
  • Time of Maximum Vapor Pressure(time_max_vap_pres)


Back To Table of Contents

DQRID : D040524.2
Start DateStart TimeEnd DateEnd Time
04/14/2004050507/13/20041525
Subject:
SGP/SMOS/E11 - Sensor failing during saturation conditions
DataStreams:sgp1smosE11.b1, sgp30smosE11.b1, sgp1440smosE11.b1
Description:
RH% readings from this sensor exceeded the 104% threshold during saturated conditions.  
Sensor replaced.
Measurements:sgp1smosE11.b1:
  • Vapor Pressure (kiloPascals)(vap_pres)
  • Relative humidity scaled, by total column amount from MWR(rh)

sgp1440smosE11.b1:
  • Minimum Vapor Pressure(min_vap_pres)
  • Time of Maximum Vapor Pressure(time_max_vap_pres)
  • Maximum Relative Humidity(max_rh)
  • Time of Minimum Vapor Pressure(time_min_vap_pres)
  • Time of Minimum Relative Humidity(time_min_rh)
  • Maximum Vapor Pressure(max_vap_pres)
  • Minimum Relative Humidity(min_rh)
  • Time of Maximum Relative Humidity(time_max_rh)

sgp30smosE11.b1:
  • Standard deviation of Relative Humidity(sd_rh)
  • Vapor Pressure (kiloPascals)(vap_pres)
  • Relative humidity scaled, by total column amount from MWR(rh)
  • Standard deviation of Vapor Pressure(sd_vap_pres)


Back To Table of Contents

DQRID : D040524.3
Start DateStart TimeEnd DateEnd Time
05/12/2004153206/28/20041520
Subject:
SGP/SMOS/E21 - Sensor failure
DataStreams:sgp1smosE21.b1, sgp30smosE21.b1, sgp1440smosE21.b1
Description:
The Barometer failed the 6 month calibration checks. PM tried to replace the barometer on 
5/12, but the new barometer would not work correctly. Pressure readings are 
missing/offscale from 5/12 1532 through 06/28/2003.  New barometer installed on 06/28/2003.
Measurements:sgp1smosE21.b1:
  • barometric pressure(bar_pres)

sgp30smosE21.b1:
  • barometric pressure(bar_pres)
  • Standard deviation of Barometric Pressure(sd_bar_pres)

sgp1440smosE21.b1:
  • Maximum Barometric Pressure(max_bar_pres)
  • Time of Maximum Barometric Pressure(time_max_bar_pres)
  • Minimum Barometric Pressure(min_bar_pres)
  • Time of Minimum Barometric Pressure(time_min_bar_pres)


Back To Table of Contents

DQRID : D050421.10
Start DateStart TimeEnd DateEnd Time
04/01/2001000003/09/20051739
Subject:
SGP/SMOS/E4 - Reprocess: Wind direction offset
DataStreams:sgp1smosE4.b1, sgp30smosE4.b1
Description:
When the SGP.E4 SMOS tower was installed it was not aligned
properly resulting in a 7 degree offset.  On 3/9/05, the
datalogger program was modifed to correct for this offset.
Measurements:sgp1smosE4.b1:
  • Unit Vector Wind Direction(wdir)

sgp30smosE4.b1:
  • Unit Vector Wind Direction(wdir)


Back To Table of Contents

DQRID : D050421.7
Start DateStart TimeEnd DateEnd Time
04/02/2001000003/09/20051705
Subject:
SGP/SMOS/E3 - Reprocess: Wind direction offset
DataStreams:sgp1smosE3.b1, sgp30smosE3.b1
Description:
When the SGP.E3 SMOS tower was installed it was not aligned
properly resulting in a 7 degree offset.  On 3/9/05, the 
datalogger program was modified to correct for this offset.
Measurements:sgp1smosE3.b1:
  • Unit Vector Wind Direction(wdir)

sgp30smosE3.b1:
  • Unit Vector Wind Direction(wdir)


Back To Table of Contents

DQRID : D050422.2
Start DateStart TimeEnd DateEnd Time
04/01/2001000003/10/20051610
Subject:
SGP/SMOS/E6 - Reprocess: Wind direction offset
DataStreams:sgp1smosE6.b1, sgp30smosE6.b1
Description:
When the SGP.E6 SMOS tower was installed it was not aligned
properly resulting in a 7 degree offset.  On 3/10/05, the
datalogger program was modified to correct for this offset.
Measurements:sgp1smosE6.b1:
  • Unit Vector Wind Direction(wdir)

sgp30smosE6.b1:
  • Unit Vector Wind Direction(wdir)


Back To Table of Contents

DQRID : D050422.5
Start DateStart TimeEnd DateEnd Time
04/01/2001000003/08/20052015
Subject:
SGP/SMOS/E7 - Reprocess: Wind direction offset
DataStreams:sgp1smosE7.b1, sgp30smosE7.b1
Description:
When the SGP.E7 SMOS tower was installed it was not aligned
properly resulting in a 6 degree offset.  On 3/08/05, the
datalogger program was modified to correct for this offset.
Measurements:sgp30smosE7.b1:
  • Unit Vector Wind Direction(wdir)

sgp1smosE7.b1:
  • Unit Vector Wind Direction(wdir)


Back To Table of Contents

DQRID : D050422.9
Start DateStart TimeEnd DateEnd Time
10/13/2003000005/11/20051615
Subject:
SGP/SMOS/E27 - Reprocess: Wind direction offset
DataStreams:sgp1smosE27.b1, sgp30smosE27.b1
Description:
When the SGP.E27 SMOS tower was installed it was not aligned
properly resulting in a 7 degree offset.
Measurements:sgp1smosE27.b1:
  • Unit Vector Wind Direction(wdir)

sgp30smosE27.b1:
  • Unit Vector Wind Direction(wdir)


Back To Table of Contents



END OF DATA