Data Quality Reports for Session: 102133 User: ql_data Completed: 10/17/2006


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D051101.6SGP/ECOR/E1 - ECOR Pressure and Temperature Missingsgp30ecorE1.b1
D051101.8SGP/ECOR/E3 - CO2/H2O Sensor Not Workingsgp30ecorE3.b1
D060104.1SGP/ECOR/E16 - Sonic serial communication errors caused incorrect fluxessgp30ecorE16.b1
D060531.3SGP/ECOR/E10 - Reprocess: Wind Direction Incorrectsgp30ecorE10.b1


DQRID : D051101.6
Start DateStart TimeEnd DateEnd Time
10/05/2005140005/31/20061930
Subject:
SGP/ECOR/E1 - ECOR Pressure and Temperature Missing
DataStreams:sgp30ecorE1.b1
Description:
The pressure and temperature from the CO2/H2O sensor is missing due to a failure of some 
kind.
Measurements:sgp30ecorE1.b1:
  • average temperature (IGRA internal sensor)(temp_irga)
  • average atmospheric pressure (IGRA internal sensor)(atm_pres)


Back To Table of Contents

DQRID : D051101.8
Start DateStart TimeEnd DateEnd Time
09/29/2005110002/08/20061700
Subject:
SGP/ECOR/E3 - CO2/H2O Sensor Not Working
DataStreams:sgp30ecorE3.b1
Description:
The CO2/H2O sensor failed.  Means and fluxes of CO2 and H2O (lv_e) are incorrect or 
missing.
Measurements:sgp30ecorE3.b1:
  • variance of variable q(var_q)
  • covariance vq(cvar_vq)
  • covariance uc(cvar_uc)
  • covariance uq(cvar_uq)
  • rotated covariance uq(cvar_rot_uq)
  • covariance vc(cvar_vc)
  • rotated covariance vc(cvar_rot_vc)
  • average atmospheric pressure (IGRA internal sensor)(atm_pres)
  • latent heat flux(lv_e)
  • mean co2 concentration (c)(mean_c)
  • CO2 flux(fc)
  • rotated covariance uc(cvar_rot_uc)
  • covariance wc(cvar_wc)
  • variance of variable c(var_c)
  • covariance of tq(cvar_tq)
  • mean water vapor concentration (q)(mean_q)
  • rotated covariance wq(cvar_rot_wq)
  • average temperature (IGRA internal sensor)(temp_irga)
  • covariance wq(cvar_wq)
  • covariance of qc(cvar_qc)
  • rotated covariance wc(cvar_rot_wc)
  • covariance of tc(cvar_tc)
  • rotated covariance vq(cvar_rot_vq)


Back To Table of Contents

DQRID : D060104.1
Start DateStart TimeEnd DateEnd Time
11/09/2005163001/18/20061230
Subject:
SGP/ECOR/E16 - Sonic serial communication errors caused incorrect fluxes
DataStreams:sgp30ecorE16.b1
Description:
Communication problem on the serial connection to the SONIC 
              caused data dropouts and subsequent data corruption.  In entering 
              the ECOR Linux box through the sonic serial port, the serial port 
              or the Linux driver handling it (likely the latter) sometimes 
              drops entire fields (one or more) within a line of raw sonic 
              data.  When that happens, the ECOR programming can not properly 
              parse the data (if it's not there to parse) and so the flux and 
              mean measurements come out as garbage in the 30 minute ECOR data 
              that is collected for ingest.
Measurements:sgp30ecorE16.b1:
  • latent heat flux(lv_e)
  • corrected sensible heat flux(h)
  • average atmospheric pressure (IGRA internal sensor)(atm_pres)
  • mean co2 concentration (c)(mean_c)
  • average temperature (IGRA internal sensor)(temp_irga)
  • mean water vapor concentration (q)(mean_q)
  • CO2 flux(fc)


Back To Table of Contents

DQRID : D060531.3
Start DateStart TimeEnd DateEnd Time
10/03/2003190005/25/20061800
Subject:
SGP/ECOR/E10 - Reprocess: Wind Direction Incorrect
DataStreams:sgp30ecorE10.b1
Description:
It was discovered that the E10 ECOR boom is aligned 17 degrees to the west of true north.  
Therefore, all wind direction data for the stated period is 17 degrees too high.  
Subtract 17 degrees from the wind direction to give the correct direction.

The E10 configuration file was modified to correct this problem.
Measurements:sgp30ecorE10.b1:
  • vector averaged wind direction(wind_dir)


Back To Table of Contents



END OF DATA