Data Quality Reports for Session: 100114 User: pubnico Completed: 06/16/2006


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D040127.3TWP/SONDE/C2 - Broken temperature sensorstwpsondewnpnC2.b1
D040208.2TWP/SONDE/C2 - Questionable rH datatwpsondewnpnC2.b1
D040228.1TWP/SONDE/C1 - Broken temperature sensortwpsondewnpnC1.b1
D040228.3TWP/SONDE/C1 - Bad RH sensorstwpsondewnpnC1.b1


DQRID : D040127.3
Start DateStart TimeEnd DateEnd Time
10/13/200304010/13/200323
11/08/2003233511/09/2003215
11/18/200312511/18/20031340
11/19/2003115611/19/20031346
11/21/200304411/21/2003113
12/20/2003122512/20/2003148
12/21/200305612/21/2003126
12/21/2003115512/21/20031344
12/23/200304212/23/2003212
12/23/2003113712/23/20031259
12/23/2003234212/24/2003132
01/08/2004113501/08/2004139
01/09/2004115701/09/20041342
01/09/2004135901/09/20041537
01/12/2004234201/13/2004214
01/16/200414901/16/20041548
01/16/2004233701/17/200419
01/18/2004113501/18/20041256
01/19/200422301/19/2004346
01/19/2004232901/20/2004157
01/21/2004125201/21/2004140
01/22/200405201/22/2004227
01/23/2004113701/23/20041319
01/26/200412201/26/2004146
02/17/200414602/17/20041536
02/26/2004122102/26/20041350
03/09/2004114503/09/20041315
03/14/2004113103/14/2004130
03/22/2004113403/22/2004130
03/29/2004233203/30/2004047
03/30/2004233403/31/2004059
04/11/2004234804/12/2004120
05/01/2004233505/02/2004110
05/02/2004233605/03/200419
05/13/2004233405/14/2004112
05/14/200414605/14/20041411
06/07/200422406/07/2004351
06/25/2004114606/25/20041328
07/02/200405907/02/2004217
07/20/200422007/20/2004358
07/24/2004123507/24/20041355
08/22/2004114408/22/2004127
09/08/2004142509/08/2004165
09/08/2004233809/08/20042345
10/18/2004234610/19/2004128
11/29/2004232111/30/200415
12/08/2004114312/08/2004136
12/30/2004113012/30/20041239
Subject:
TWP/SONDE/C2 - Broken temperature sensors
DataStreams:twpsondewnpnC2.b1
Description:
The temperature sensors on these radiosondes broke after launch.  All
temperature-related data are incorrect.
Measurements:twpsondewnpnC2.b1:
  • Relative humidity scaled, by total column amount from MWR(rh)
  • Dry-Bulb Temperature(tdry)
  • Surface dew point temperature(dp)


Back To Table of Contents

DQRID : D040208.2
Start DateStart TimeEnd DateEnd Time
02/04/2004114702/04/20041337
Subject:
TWP/SONDE/C2  - Questionable rH data
DataStreams:twpsondewnpnC2.b1
Description:
It appears that the RH sensor heating circuit failed during this sounding.  The RH 
oscillates rapidly between low (~0 %RH) and not so low (ambient %RH) and the oscillation seems 
to stop when the temperature is below ~35 degC.  According to Vaisala these are symptoms 
of failure in the ASIC (application specific integrated circuit) that controls the heating.
Measurements:twpsondewnpnC2.b1:
  • Relative humidity scaled, by total column amount from MWR(rh)
  • Surface dew point temperature(dp)


Back To Table of Contents

DQRID : D040228.1
Start DateStart TimeEnd DateEnd Time
02/07/2004234202/08/2004115
02/09/2004113302/09/20041233
04/05/2004233204/06/200415
04/22/2004115604/22/20041317
04/24/2004113004/24/20041312
04/29/2004113704/29/20041312
04/30/2004233605/01/2004112
05/03/2004233105/04/200415
05/05/2004113505/05/20041319
05/07/2004113205/07/20041315
05/11/2004114205/11/20041311
05/12/2004114505/12/2004126
05/18/2004113005/18/20041321
07/10/2004113007/11/20041255
07/13/2004113907/13/20041320
07/16/2004234607/17/200417
07/22/2004235507/23/2004140
07/26/2004234107/27/2004115
08/14/2004233008/15/200414
08/22/2004233508/23/200415
09/05/2004234009/06/2004119
09/14/2004232809/14/20042329
09/17/2004233209/18/200412
10/28/2004233610/29/2004057
11/28/2004235211/29/2004044
Subject:
TWP/SONDE/C1 - Broken temperature sensor
DataStreams:twpsondewnpnC1.b1
Description:
The temperature sensor on these radiosondes broke after launch
All the temperature-related data are incorrect.
Measurements:twpsondewnpnC1.b1:
  • Surface dew point temperature(dp)
  • Relative humidity scaled, by total column amount from MWR(rh)
  • Dry-Bulb Temperature(tdry)


Back To Table of Contents

DQRID : D040228.3
Start DateStart TimeEnd DateEnd Time
02/06/2004234102/06/2004130
Subject:
TWP/SONDE/C1 - Bad RH sensors
DataStreams:twpsondewnpnC1.b1
Description:
It appears that the RH sensor heating circuit failed during this portion of the sounding 
(approximately between 0km and 12km).  The RH oscillates rapidly in a 20% range and the 
oscillation seems to stop when the temperature is below ~45 degC.  These are symptoms of 
failure in the ASIC (application specific integrated circuit) that controls the heating.
Measurements:twpsondewnpnC1.b1:
  • Surface dew point temperature(dp)
  • Relative humidity scaled, by total column amount from MWR(rh)


Back To Table of Contents