Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/12/1995 | 1315 | 04/12/1995 | 1400 |
04/11/1995 | 1230 | 04/12/1995 | 0615 |
Subject: | SGP/EBBR/E26 - Stopped Ventilation Fan |
DataStreams: | sgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1 |
Description: | On April 11, 1995, a site operator discovered the right aspirator ventilation fan of the EBBR to be stopped. Inspection of the data indicates that this condition occurred during the two periods shown above; the fan apparently worked briefly inbetween the periods. Lack of ventilation of the temperature and relative humidity sensors attached to the AEM results in incorrect measurements of air temperature and relative humidity by the right aspirator probes, and therefore all quantities calculated from them, including sensible and latent heat fluxes, are incorrect as well. The quantities that are incorrect for the periods indicated are: 5 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot, vp_top, and vp_bot 15 minute: rr_thum_r, mv_hum_r, tair_r 30 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot, vp_top, vp_bot, bowen, e, h |
Suggestions: | |
Measurements: | sgp5ebbrE26.b1: more
sgp15ebbrE26.b1: more sgp30ebbrE26.b1: more |