DQRID : D040225.10
Start DateStart TimeEnd DateEnd Time
02/05/2004163102/09/20041926
more
Subject:
SGP/TWR/C1 - Temperature Sensor Not Connected to Datalogger
DataStreams:sgp30twr10xC1.b1, sgp1twr10xC1.b1
Description:
One of the southeast side 25 m Temperature sensor leads was pulled out from the CR10X 
datalogger terminal strip.
Suggestions: 
Use the 25 m temperature measurement from the west side of the tower.
Measurements:sgp30twr10xC1.b1:
  • Temperature at 25 m(temp_25m)
  • 25 m Vapor Pressure(vap_pres_25m)
more
sgp1twr10xC1.b1:
  • 25 m Vapor Pressure(vap_pres_25m)
  • Temperature at 25 m(temp_25m)
more

Close this window