Subject: | SGP/SONDE/C1 - Contaminated by interference |
DataStreams: | sgpsondeC1.00, sgpsondewnpnC1.b1, sgpsondewnpnC1.a1
|
Description: | These three soundings are contaminated by interference from another radiosonde. It is not
clear why; this doesn't usually happen at the CF where the operators are very
experienced and frequency separation is not usually a problem. |
Suggestions: | Caveat emptor. |
Measurements: | sgpsondeC1.00: - (Raw data stream - documentation not supported)
more
sgpsondewnpnC1.b1: - base time in epoch(base_time)
- -180.0 - +180.0(alt)
- Dry Bulb Temperature(tdry)
- Time offset from base_time(time_offset)
- Easterly Wind Component(u_wind)
- Wind status(wstat)
- Ascent rate(asc)
- North Latitude(lat)
- Retrieved pressure profile(pres)
- Dewpoint Temperature(dp)
- lon(lon)
- V wind component(v_wind)
- Relative Humidity (hybrid-b grid)(rh)
- Wind Direction(deg)
- Wind Speed(wspd)
more
sgpsondewnpnC1.a1: - Easterly Wind Component(u_wind)
- Wind status(wstat)
- Time offset from base_time(time_offset)
- Wind Speed(wspd)
- Dewpoint Temperature(dp)
- lon(lon)
- Wind Direction(deg)
- V wind component(v_wind)
- Dry Bulb Temperature(tdry)
- Relative Humidity (hybrid-b grid)(rh)
- Retrieved pressure profile(pres)
- Ascent rate(asc)
- -180.0 - +180.0(alt)
- base time in epoch(base_time)
- North Latitude(lat)
more
|