Subject: | TWP/SKYRAD/C1 - NIP: Moisture inside NIP |
DataStreams: | twpskyrad60sC1.b1
|
Description: | The NIP took on a significant amount of moisture during a rainy period
that ended on 970719. From this date until the RESET visit in August,
the NIP data is corrupted. The errors are large (often greater than
100 W/m^2 in the direct beam) in the morning but tend to converge to
the expected values in the afternoon. In general, NIP data from this
period should be used with extreme caution. |
Suggestions: | use with extreme caution, much of the data are corrupt |
Measurements: | twpskyrad60sC1.b1: - Shortwave direct normal irradiance, pyrheliometer(short_direct_normal)
- Shortwave Direct Normal Irradiance, Pyrgeometer, Standard Deviation(short_direct_normal_std)
- Shortwave direct normal irradiance, pyrheliometer, minima(short_direct_normal_min)
- Shortwave Direct Normal Irradiance, Pyrheliometer, Maxima(short_direct_normal_max)
more
|