Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
04/29/1997 | 2003 | 04/29/1997 | 2030 | Incorrect |
Subject: | SGP/EBBR/E8 - EBBR Biannual Checks |
DataStreams: | sgp30ebbrE8.b1, sgp15ebbrE8.b1, sgp5ebbrE8.b1 |
Description: | During EBBR 3 month checks the Automatic Exchange Mechanism is disabled (reflected by home signals near zero) so that the two aspirator units can be placed at the same height. The measurements during these periods do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h), or latent heat flux (e), nor do the air temperature and relative humidity measurements indicate correct gradients. Checks performed before or after the AEM is disabled also lead to some incorrect data. Incorrect 5, 15 minute and half hour data occurs for periods indicated. |
Suggestions: | |
Measurements: | sgp5ebbrE8.b1: more
sgp15ebbrE8.b1: more sgp30ebbrE8.b1: more |