Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
06/10/1997 | 2030 | 07/14/1997 | 0915 | Incorrect |
Subject: | SGP/EBBR/E8 - Reprocess: E8 EBBR Program Compile Error, Effect On Net Radiation |
DataStreams: | sgp30ebbrE8.b1, sgp15ebbrE8.b1, sgp5ebbrE8.b1 |
Description: | An error in CR10X program compilation occurred when new software was used to perform the compilation. The new software created an erroneous data table listing, which the program works off of. An incorrect data location was used in the adjustment of net radiation for wind speed, causing all net radiation values to be divided by 2. The following data was incorrect during the period above: 5 minute: q 15 minute: mv_q 30 minute: q, e, h The latent and sensible heat fluxes can be corrected by recomputing as follows: e = -(2q + ave_shf)/(1 + bowen) h = -(e + ave_shf + 2q) |
Suggestions: | Recalculate latent and sensible heat fluxes using the equations provided. |
Measurements: | sgp5ebbrE8.b1: more
sgp15ebbrE8.b1: more sgp30ebbrE8.b1: more |