Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
09/20/1996 | 1430 | 09/20/1996 | 1500 | Incorrect |
Subject: | SGP/EBBR/E9 - Air Temperature Thermocouples Incorrect |
DataStreams: | sgp5ebbrE9.b1, sgp30ebbrE9.b1, sgp15ebbrE9.b1 |
Description: | Both air temperature thermocouples were offscale, for unknown reasons, for 1500 GMT for both 15 and 30 minute air temperature values. The malfunction of the air temperature thermocouples results in incorrect Bowen ratio, sensible heat flux, and latent heat flux during the period above. The data values that are affected are: 5 minute: tair_top, tair_bot 15 minute: tair_r, tair_l 30 minute: tair_top, tair_bot, bowen, e, and h |
Suggestions: | |
Measurements: | sgp30ebbrE9.b1: more
sgp15ebbrE9.b1: more sgp5ebbrE9.b1: more |